Laserfiche WebLink
Forensic Analytical Laboratories Final Report <br /> Metals Analysis of HUD Wipes <br /> r <br /> State of California Client ID: L1009 <br /> Prevention Branch Report Number: M101838 <br /> Childhood Lead Poisoning Date Received: 04/03/09 <br /> $50 Marina Bay Pkwy.,Bldg. P Date Analyzed: 04/09/09 <br /> Richmond,CA 94804 Date Printed: 04/09/09 <br /> First Reported: 04/09/09 <br /> i <br /> Job ID/Site: 38 South Airport Way,Stockton, San Joaquin,95206 <br /> FALI Job ID: L1009 <br /> Date(s)Collected: 03/30/09 Total Samples Submitted: 4 <br /> Total Samples Analyzed: 4 <br /> Area Result Reporting Method <br /> Sample Number Lab Number fl2 Analyte .Result Units Limitsr <br /> Referen ca <br /> Dl 30343930 1.00 Pb 31 ug/f12 8 NIOSH 9100/7082 <br /> D2 30343931. 1.00 Pb <8 ug/f12 8 NIOSH 9100/7082 1 <br /> D3 30343932 0.86 Pb 60 ug/ft2 10 NIOSH 9100/7082 <br /> D4 30343933 Ph <8 ug 8 NIOSH 9100/7082 i <br /> 1 <br /> Note to clients performing work related In the tend Based Paint Harard Reduction Act:Sample results for wipes not meeting A STM E 1792 arenot recogtiired within the Nalional Lead <br /> Laboratory Accreditation Pmg-am <br /> Forensic Aral+kcal can not deteriiine whether or not wipes submitted to us fer analysis meet die ASPM standard. W ereconnnend to our clients that they document the brind of wipe that they <br /> use for each sutmi:sion on their sample request form. <br /> I <br /> M <br /> * The Reporting Limit represents the lowest amount of analyte that the laboratory can confidently detect in the sample,and is not a <br /> regulatory level. The Units for the Reporting Limit are the same as the Units for the Final Results. <br /> Dave Sandusky, Laboratory Supervis r,Hayward Laboratory <br /> Analytical results and reports arc generated by Forensic Analytical at the request of and for the exclusive use of the person or entity(client)named on such report.Results. <br /> reports or copies of same will not be released by Forensic Analytical to any third party without prior written request from client,This report applies only to the sample(s) <br /> tested.Supporting laboratory documentation is available upon request.This report must not be reproduced except in full,unless approved by Forensic Analytical.The client <br /> is solely responsible for(lie use and interpretation of test results and reports requested from Forensic Analytical,Forensic Analytical is not able to assess the degree of hazard l <br /> resulting from materials analyzed. Forensic Analytical reserves the right to dispose of all samples after a period of thirty(30)days,according to all state and federal <br /> guidelines, unless otherwise specified.Any modifications that have been made to referenced test methods are documented in Forensic Analytical's Standard Operating <br /> Procedures Manual.Sample results have not been blank corrected. Quality control and sample receipt condition were acceptable unless otherwise noted. <br /> I of 1 <br /> 3777 Depot Road,Suite 409,Hayward,CA 94545 / Telephone:(510)887-8828 (800)827-FASI / Fax:(510)887-4218 <br />