Laserfiche WebLink
SIU I Environmental Health Department <br /> - i RUNTY I <br /> Greotness grows here Time In: 945 am <br /> Time Out: 10:20 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: VILLAGE OF THE PINES APTS Date: 07/19/2021 <br /> Address: 1350 BUCKINGHAM WAY, STOCKTON 95207 <br /> Owner/Operator: DELTA BAY PROPERTIES Telephone: (209)478-0318 <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #8 Pool and Deck Lighting <br /> OBSERVATIONS:Pool light is not operational. Post sign that states" No use of pool allowed after dark"and secure the <br /> pool area after dark. <br /> CALCODE DESCRIPTION:Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br /> pool. When a pool is used at night,pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br /> not operational, the pool operator shall post a sign in 4-inch letters stating"NO USE OF POOL ALLOWED AFTER DARK"and shall <br /> secure the pool area and not permit any use of the pool after dark. (31158) <br /> #9 Ladders and Handrails <br /> OBSERVATIONS:Hand rails are loose. Secure hand rails. <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed.At least one handrail shall extend from the deck to not less than a point <br /> above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 311 1B)Pool <br /> operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 80 gpm Chlorine: 5.6 ppm Temp: ° F <br /> Cyanuric acid: 100 ppm pH: 7.4 Combined chlorine: ppm <br /> NOTES <br /> Influent: 15 psi <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code.If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: Theresa Hernandez, Manager <br /> EH Specialist: FRANCISCO RUIZ Phone: (209)616-3032 <br /> FA0001455 PR0360171 SCO01 07/19/2021 <br /> EHD 36-01 Rev.09/16/2020 Page 1 of 1 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />