My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOWLAND
>
16700
>
1900 - Hazardous Materials Program
>
PR0512801
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/18/2021 10:43:04 AM
Creation date
8/18/2021 2:48:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1900 - Hazardous Materials Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0512801
PE
1921
FACILITY_ID
FA0010513
FACILITY_NAME
PG&E HOWLAND RD SUBSTATION
STREET_NUMBER
16700
STREET_NAME
HOWLAND
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
198-140-03
CURRENT_STATUS
01
SITE_LOCATION
16700 HOWLAND RD
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J 0 A Q U 1 N Environmental Health Department <br /> U ; i y 1 Iii AMENDED <br /> 8/13/2021 <br /> Hazardous Materials Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> PG&E HOWLAND RD SUBSTATION 16700 HOWLAND RD, LATHROP August 11, 2021 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 7 HSC 25505(a)(3) Failed to electronically submit an adequate ER procedures for a release or threatened release. <br /> OBSERVATION: The emergency response procedures and contingency plan have not been annually <br /> certified/submitted as a part of the business plan.The emergency response procedures and contingency plan were <br /> not submitted for the year of 2021. The emergency response procedures and contingency plan have not been <br /> submitted since 1/15/2020. <br /> REGULATION GUIDANCE: Per H&SC 25508.2, the business owner/operator shall annually review and certify that <br /> the business plan is complete, accurate, up-to-date and in compliance with Section 11022 of Title 42 of the United <br /> States Code.An annual electronic submittal satisfies these requirements.The annual business plan shall be <br /> submitted/certified by January 15 of each calendar year and may be submitted beginning November 1 of the <br /> previous year. <br /> CORRECTIVE ACTION: Immediately log into the CERS at http://cers.calepa.ca.gov/, review and submit/certify the <br /> current information. <br /> This is a Class II violation. <br /> 8 HSC 25505(a)(4) Failed to establish and electronically submit a reasonable or an adequate training program. <br /> OBSERVATION: The training program has not been annually certified/submitted as a part of the business plan.The <br /> employee training program was not submitted for the year of 2021.The training program has not been submitted <br /> since 1/15/2020. <br /> REGULATION GUIDANCE: Per H&SC 25508.2, the business owner/operator shall annually review and certify that <br /> the business plan is complete, accurate, up-to-date and in compliance with Section 11022 of Title 42 of the United <br /> States Code.An annual electronic submittal satisfies these requirements.The annual business plan shall be <br /> submitted/certified by January 15 of each calendar year and may be submitted beginning November 1 of the <br /> previous year. <br /> CORRECTIVE ACTION: Immediately log into the CERS at http://cers.calepa.ca.gov/, review and submit/certify the <br /> current information. <br /> This is a Class II violation. <br /> FA0010513 PR0512801 SCO01 08/11/2021 <br /> EHD 19-01 Rev.9/16/2020 Page 3 of 4 Hazardous Materials Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />