Laserfiche WebLink
��Lawton <br />Tulsa0 <br />Tulsa O8, 74107 <br />918-998-0862 <br />ACUREN <br />DATA SHEET External <br />CODES: HC= HEAVY <br />DATE: 12/16/2016 <br />TECH: Gregory Fann <br />EQUIP. #: 450 Gallon Salvage Oil Tank <br />COMPANY: Owens Brockway <br />PLANT: Tracy Ca <br />AREA: NA <br />0 -REFERENCE: South West Corner <br />Top <br />Bottom <br />SW <br />0.179 <br />NA <br />sE <br />0.189 <br />0.181 <br />Mid East <br />0.187 <br />0.175 <br />Mid West <br />NA <br />NA <br />NW <br />0.181 <br />0.180 <br />NE <br />0.189 <br />0.178 <br />East Side <br />West Side <br />S Top <br />0.189 <br />0.187 <br />S Bottom <br />0.181 <br />NA <br />Middle <br />0.184 <br />0.182 <br />N Tap <br />0.18 <br />0.18 <br />N Bottom <br />0.188 <br />0.179 <br />North End <br />South End <br />Top Lett <br />0.189 <br />0.187 <br />Top Right <br />0.187 <br />0.188 <br />Middle <br />0.185 <br />0.188 <br />BTM Left <br />0.189 <br />0.191 <br />BTM Right <br />0.181 <br />0.189 <br />CORROSION / NZ= NOZZLE / MW= MANWAY / NA= NO ACCESS / TR= TOO ROUGH / SI= STRUCTURAL INTERFERENCE <br />NOTE INTERNAL OR EXTERNAL INSPECTION PER COMPONENT <br />TECHNICIAN COMMENTS <br />All readings acuired started at the west end (1") at zero (top) rotating north. <br />