Laserfiche WebLink
Project Name: Raising Canes Manteca NRCC-PRF-01-E Page 4 of 17 Project Name: Raising Canes Manteca NRCC-PRF-01-E Page 1 of 17 <br /> Project Address: 1311 Yosemite Avenue Manteca 95336 Calculation Date/Time: 19:57,Thu,Jul 30,2020 Project Address: 1311 Yosemite Avenue Manteca 95336 Calculation Date/Time: 19:57,Thu,Jul 30,2020 <br /> Input File Name: 20-0721 Mech Calcs.cibd19x Input File Name: 20-0721 Mech Calcs.cibd19x <br /> H. FENESTRATION ASSEMBLY SUMMARY§110.6 A.GENERAL INFORMATION <br /> 1. 2. 3. 4. 5. 6. 7. 8. 9. 1. Project Location(city) Manteca 8. Standards Version Compliance2019 <br /> Fenestration Assembly Name/Tag Fenestration Type/Product Type/ Certification Method' Assembly Method Area ft' Overall Overall Overall v 2. CA Zip Code 95336 9. Compliance Software(version) EnergyPro 8.1 <br /> or I.D. Frame Type U-factor SHGC VT N <br /> 3. Climate Zone 12 10. Weather File STOCKTON_724920_CZ2010.epw <br /> VerticalFenestration 4. Total Conditioned Floor Area in Scope 2,649 ftZ 11. Building Orientation(deg) (E)90 deg <br /> Title 24 Compliant Windows FixedWindow NFRC Rated SiteBuilt 403 0.36 0.25 0.50 N <br /> N/A S. Total Unconditioned Floor Area 0 ftZ 12. Permitted Scope of Work NewEnvelopeAnd Mechanical <br /> VerticalFenestration 6. Total#of Stories(Habitable Above Grade) 1 13 Building Type(s) Nonresidential <br /> Title 24 Compliant Door GlazedDoor NFRC Rated SiteBuilt 48 0.45 0.23 0.50 N 7, Total#of dwelling units 0 14 Gas Type NaturalGas <br /> N/A <br /> VerticalFenestration <br /> Title 24 Compliant DT Window OperableWindow NFRC Rated SiteBuilt 17 0.46 0.22 0.50 N B. PROJECT SUMMARY <br /> N/A Table Instructions:Table B shows which building components are included in the performance calculation.If indicated as not included,the project must show compliance prescriptively if within <br /> 'Newly installed fenestration shall have a certified NFRC Label Certificate or use the CEC default tables found in Table 110.6-A and Table 110.6-B.Center of Glass(CDG)values are for the glass-only,determined by the manufacturer,and are shown for ease permit application. <br /> of verification.Site-built fenestration values are calculated per Nonresidential Appendix NA6 and are used in the analysis. <br /> z Status:N-New,A-Altered,E-Existing Building Components Complying via Performance Building Components Complying Prescriptively <br /> ® Performance ® Performance The following building components are ONLY eligible for prescriptive <br /> I. ENVELOPE DETAILS§120.7&§140.3 Envelope Covered Process:Commercial compliance and should be documented on the NRCCform listed if within the <br /> 11.OPAQUE SURFACE ASSEMBLY SUMMARY ❑ Not Included Kitchens ❑ Not Included scope of the permit application(i.e.compliance will not be shown on the <br /> NRCC-PRF-E). <br /> 1 2 3 4 5 6 7 8 9 <br /> ® Performance ❑ Performance Indoor Lighting(Unconditioned)§140.6 NRCC-LTI-E is required <br /> Framing Cavity Continuous U-Factor/F-Factor Mechanical Covered Process:Computer Rooms <br /> Surface Name Surface Type Description of Assembly Layers Area(ft') ❑ Not Included ® Not Included Outdoor Lighting§140.7 NRCC-LTO-E is required <br /> Type R-Value R-Value /C-Factor C <br /> IL ® Performance ❑ Performance Sign Lighting§140.8 NRCC-LTS-E is required <br /> 5 PSF Roof-1/2 in. Domestic Hot Water Covered Process:Laboratory Exhaust <br /> Cellular polyisocyanurate(unfaced)-5 El Not Included ® Not Included Mandatory Measures <br /> Roof8 Roof in.R29 1924 NA 0 29 U-Factor:0.032 N <br /> Electrical power systems,commissioning and solar ready requirements are <br /> Plywood-3/4 in. ❑ Performance mandatory and should be documented on the NRCC form listed if applicable <br /> Slab Type=UnheatedSlabOnGrade Lighting(Indoor Conditioned) (i.e.compliance will not be shown on the NRCC-PRF-E.) <br /> Slab-On Grade10 Underground Floor Insulation Orientation=None 2649 NA 0 NA F-Factor:0.730 N ® Not Included Electrical Power Distribution 5110.11 NRCC-ELC-E is required <br /> Insulation R-Value=RO <br /> ❑ Performance Commissioning 5120.8 NRCC-CXR-E is required <br /> Stucco-7/8 in. Solar Thermal Water Heating <br /> Vapor permeable felt-1/8 in. ® Not Included Solar Ready 5110.10 NRCC SRA E is required <br /> R-19 WaII12 ExteriorWall Plywood-1/2 in. 2406 Wood 19 NA U-Factor:0.068 N <br /> Wood framed wall,16in.OC,5.5in.,R-19 <br /> Gypsum Board-1/2 in. <br /> CA Building Energy Efficiency Standards-2019 Nonresidential Compliance Report Version:NRCC-PRF-01-E-04282020-6206 Report Generated at:2020-07-3019:58:04 CA Building Energy Efficiency Standards-2019 Nonresidential Compliance Report Version:NRCC-PRF-01-E-04282020-6206 Report Generated at:2020-07-30 19:58:04 <br /> Project Name: Raising Canes Manteca NRCC-PRF-01-E Page 3 of 17 <br /> Project Address: 1311 Yosemite Avenue Manteca 95336 Calculation Date/Time: 19:57,Thu,Jul 30,2020 <br /> Input File Name: 20-0721 Mech Calcs.cibdl9x O M p <br /> 3 (D <br /> D. EXCEPTIONAL CONDITIONS CD <br /> O <br /> This project includes partial performance compliance scope options.The building must show compliance with all other applicable compliance scope options(performance or prescriptively)before <br /> occupying. O O (D <br /> This project uses the Simplified Geometry Performance Modeling Approach which is not capable of modeling daylighting controls and assumes the prescriptive Secondary Daylit Control <br /> iCD <br /> requirements are met.PRESCRIPTIVE COMPLIANCE documentation(form NRCC-LTI-02-E)for the requirements of section 140.6(d)Automatic Daylighting Controls in Secondary Daylit Zones is (T( <br /> required. <br /> n � <br /> The user model includes space(s)that are designed to be served by mechanical cooling systems,but the cooling systems were not included in the simulation model.A cooling system has been CD <br /> modeled for both the proposed and standard cases. <br /> The user model includes space(s)without sufficient cooling equipment.Cooling equipment has been added to the model to meet cooling loads. n <br /> N <br /> .-r <br /> (D <br /> E. HERS VERIFICATION O D <br /> This Section Does Not Apply n 03 <br /> O M <br /> F.ADDITIONAL REMARKS O <br /> This Section Does Not Apply ED 11 <br /> C7 0 <br /> G. ENVELOPE GENERAL INFORMATION O O <br /> Z <br /> 1 2 3 4 <br /> Opaque Surfaces&Orientation Total Gross Surface Area(ftZ) Total Fenestration Area(ftz) Window to Wall Ratio(%) Z <br /> North-Facing' 0 ftz 0 ftz 00.0% --( <br /> East-Facingz 710 ftz 183 ftz 25.7% <br /> South-Facing3 532 ft' 126 ftz 23.7% <br /> West-Facing° 1,164 ftz 159 ftz 13.7% <br /> Total 2,406 ftZ 468 ftz 19.5% <br /> Roof 2,649 ft= 0 ft= 00.0% <br /> Notes: <br /> I North-Facing is oriented to within 45 degrees of true north,including 45°00'00"east of north(NE),but excluding 45°00'00"west of north(NW). <br /> Z East-Facing is oriented to within 45 degrees of true east,including 45°00'00"south of east(SE),but excluding 45°00'00"north of east(NE). <br /> 'South-Facing is oriented to within 45 degrees of true south,including 45°00'00"west of south(SW),but excluding 45°00'00"east of south(SE). <br /> 'West-Facing is oriented to within 45 degrees of true west including 45°00'00"north of due west(NW),but excluding 45°00'00"south of west(SW). <br /> W N <br /> CA Building Energy Efficiency Standards-2019 Nonresidential Compliance Report Version:NRCC-PRF-01-E-04282020-6206 Report Generated at:2020-07-3019:58:04 <br /> Project Name: Raising Canes Manteca NRCC PRF Ol E Page 2 of 17 <br /> d m <br /> Project Address: 1311 Yosemite Avenue Manteca 95336 Calculation Date/Time: 19:57,Thu,Jul 30,2020 o r <br /> CD <br /> Input File Name: 20-0721 Mech Calcs.cibd19x N-,a <br /> Cr o <br /> Cl.COMPLIANCE RESULTS FOR PERFORMANCE COMPONENTS(Annual TDV Energy Use, kBtu/ft 1-yr) 3 <br /> COMPLIES <br /> Energy Component Standard Design(TDV) Proposed Design(TDV) Compliance Margin(TDV)' m'(o <br /> m@ <br /> Space Heating 224.13 237.70 -13.57 23 3 <br /> Space Cooling 300.68 293.44 7.24 co <br /> s C)Q <br /> Indoor Fans 421.71 369.06 52.65 �' 3 m C <br /> Heat Rejection uNi m 0 <br /> Pumps&Misc. 3 ' ocl Z <br /> Domestic Hot Water 63.38 57.79 5.59 <br /> r- o � I- o � Wv <br /> Indoor Lighting 111.02 111.02 n O S (nZ <br /> -.%. �. <br /> ENERGY CTANDARIIC rnl%ADI IAKirG Tr1TAl 1 '7(1 1 Q7 1 nr;Q (11 r,1.Q1 1A r,01-11< $2 ` CD G O ( C) NO * O 0. ,�-- _< m <br /> M n Cr O =r O M O =r (D U) <br /> 1 (D c W N O :3 O 0 0 U) 0 <br /> Notes:The number in parenthesis following the Compliance Margin in column 4.represents the Percent Better than Standard. m d p Z W Q D W Q D r+ M CD O <br /> CD Ln m =' < Ill ry 03 < v - ` <br /> C2.RESULTS FOR'ABOVE CODE'QUALIFICATIONS' CD lD �0 4_ CD c0 CD �+ U nl D <br /> o �3 ry � i- W D W y * NCD (D 0 Z <br /> ❑This project is pursuing CalGreen Tier 1 ❑This project is pursuing CalGreen Tier 2 c3i fD P Cp CD W (0 (�j1 D D <br /> �. (n (D 3 Q (n W <N CO v I" <br /> CD <br /> Miscellaneous Energy Component Standard Design(TDV) Proposed Design(TDV) Compliance Margin(TDV)' Z n W O = O� >5 W CD = "I (� --s -1-r <br /> E CD <br /> Receptacle 247.88 247.88 � � W . . CD N U) <br /> CO cD N.al <br /> Process 635.89 635.89CD CD <br /> CDN N <br /> Other Ltg 77.34 77.34 <br /> N N <br /> Process Motors 20 v <br /> O (o CD T <br /> COMPLIANCE TOTAL PLUS MISCELLANEOUS COMPONENTS 2,082.03 2,030.12 51.9(2.5%) P W @ <br /> - o <br /> Notes:This table is used to document compliance with programs OTHER THAN Title 24 Part 6,if applicable. n <br /> mN <br /> ma <br /> m iv <br /> 3 <br /> C� <br /> � d <br /> n N <br /> `G d <br /> N O <br /> d� <br /> nd <br /> fn � <br /> a <br /> N <br /> CA Building Energy Efficiency Standards-2019 Nonresidential Compliance Report Version:NRCC-PRF-01-E-04282020-6206 Report Generated at:2020-07-3019:58:04 <br /> Cr) p -0 p Cn CO CO -4 M Cn A W N 1 <br /> o w j t] t] -0 _10 v cn <br /> co - co CD m v cD <br /> zO CD o o m �7 � d <br /> CD O O < N 1'1 _ten �Y f//1W/iii <br /> E3 ♦ / (zj� N c�D W CD cDN Z C j <br /> r �° ��°,_ REGIST g � rn <br /> C7 N <br /> C:) <br /> p o ay5 `' OCD <br /> � '9,p � _J o�o n � M ) <br /> rn � N rn O O-r1 �Ov mL)J O <br /> r TI w m v. 1 <br /> Z y z z n I m n l� "'� R7 I <br /> CL o T o o o *Iz EuTrXrm FiALGERS <br /> COP) M cm <br /> Cn <br /> 0 C." M <br /> D o (/� 3 cn C0 �/ �� N Z N w � <br /> x Co= � N z o '�'�� 3N�� CM w C Restaurant Support Office <br /> CM <br /> FM <br /> N o 1 0 0 M 6800 Bishop Road, Plano, TX 75024 <br /> x o o r � o o � Tele: 972-769-3100 Fax- 972-769-3101 <br /> SUBMITTALS <br />