Laserfiche WebLink
PLUMBING SPECIFICATIONS <br /> CV co <br /> 31 <br /> innai <br /> Oaa� C) ti <br /> PLUMBING FIXTURE SCHEDULE PLUMBING GENERAL NOTES PLUMBING ROUGH-IN NOTES �' C ~ N <br /> rx f <br /> CD <br /> Type of Appliance Commercial Condensing Tankless Water Heater, 1. THE TERM "THE CONTRACTOR" AS USED IN THIS SECTION SHALL DENOTE THE 1. THESE DRAWINGS ARE ACCOMPANIED BY OTHER DRAWINGS, SPECIFICATIONS AND Q E: ,i <br /> Commercial Energy Star WC-1: AMERICAN STANDARD 2234.001 OR KOHLER K-96053, VITREOUS CHINA, PLUMBING SUB-CONTACTOR. BROCHURES. DRAWINGS, SPECIFICATIONS, AND BROCHURES ARE TO BE CONSIDERED IN co o <br /> SIPHON JET, ELONGATED BOWL, FLOOR MOUNTED, 1 1/2 INCH TOP SPUD, WHOLE FOR PRICING ROUGH-IN INSTALLATION AND CONNECTIONS. THE PLUMBING L3 o 0 <br /> Rinnai model number REU-KBD3237FFUDC-US BOLT CAPS, WITH SLOAN REGAL SERIES OR ZURN AQUA FLUSH PLUS (1.28 Cc <br /> 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2019 CALIFORNIA PLUMBING CONTRACTOR SHALL REVIEW THESE DOCUMENTS FOR NOTATIONS AND COMMENTS THAT 'X. <br /> Operation / Installation Forced combustion; indoor only; GALLONS PER FLUSH) FLUSH VALVE, AND CHURCH 950OSSC, BENEKE PERTAIN TO THE PLUMBING ASPECTS OF THE PROJECT. O L� o M <br /> 527SS OR BEMIS 1655SSC, CONTOURED SOLID POLYSTYRENE, WHITE, OPEN CODE (CPC) WITH ALL LOCAL AMENDMENTS AND ORDINANCES. � � r_0 <br /> °' 'm <br /> FRONT SEAT WITH SELF SUSTAINING CHECK HINGE. 3. REVIEW PLANS OF ALL TRADES PRIOR TO BIDDING AND INSTALLATION TO INCLUDE 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REVIEWING ALL FOOD SERVICE °C o ti <br /> Minimum/Maximum Gas Rate(Input) 15,200 - 199,000 BTU/h (4.5-58.3 kWh) ALL PLUMBING FOR COMPLETE SYSTEMS SHOWN ON THE PLANS AND AS REQUIRED. CONTRACT DOCUMENTS TO ENSURE THAT ALL REQUIRED PLUMBING SERVICES ARE C=) 6' <br /> WC-2: AMERICAN STANDARD 3043.001 OR KOHLER K-96057, VITREOUS CHINA, SIPHON JET, o Q; <br /> Electrical Appliance: AC 120 Volts -60 Hz ELONGATED BOWL, FLOOR MOUNTED, 16-1/2" RIM HEIGHT, 1 1/2" TOP SPUD, BOLT PROVIDED SO AS TO COMPLETE THE PROJECT. <br /> Temperature Controller: DC 12 Volts CAPS, WITH SLOAN REGAL SERIES OR ZURN AQUA FLUSH PLUS (1.28 GALLONS PER 4. COORDINATE WITH OTHER TRADES TO PREVENT INTERFERENCE WITH HVAC DUCTS, ~ <br /> Electrical Consumption Normal: 75 w Standby: 2 w Anti-frost protection: 146 w FLUSH) FLUSH VALVE, AND CHURCH 9500SSC, BENEKE 527SS OR BEMIS 1655SSC, STRUCTURE, ELECTRICAL LIGHTING, AND OTHER PIPING IN THE CEILING SPACE. 3. DRAIN LINES FROM BUILT-IN EQUIPMENT TO BUILT-IN DRAIN VALVES SHALL BE <br /> CONTOURED SOLID POLYSTYRENE, WHITE, OPEN FRONT SEAT WITH SELF SUSTAINING VENT PIPING AND WATER PIPING SHALL BE HELD EITHER ABOVE OR BELOW HVAC PROVIDED BY THE FOOD SERVICE EQUIPMENT CONTRACTOR. DRAIN LINES FROM <br /> Amperage Max: 4A CHECK HINGE. DUCTWORK AS COORDINATED WITH THE HVAC CONTRACTOR. BUILT-IN DRAIN VALVES SHALL BE EXTENDED TO WASTE BY THE PLUMBING <br /> CONTRACTOR. <br /> Ignition System Direct electronic ignition WATER CLOSET SHALL BE DESIGNED AND INSTALLED TO MEET THE AMERICANS WITH 5. ALL CHANGES SHALL REQUIRE THE APPROVAL OF THE ARCHITECT/OWNER. <br /> Hot Water Capacity Minimum flow rate: 0.26 GPM (1 I/min) DISABILITIES ACT (ADA) STANDARD FOR PHYSICALLY IMPAIRED PEOPLE AND ANSI 117.1 4. ALL DRAIN LINES PROVIDED BY THE FOOD SERVICE EQUIPMENT CONTRACTOR AND THE <br /> Minimum activation flow rate: 0.4 GPM (1.5 I/min) STANDARD. FLUSH VALVE HANDLE SHALL BE CONSTRUCTED TO MEET ADA, SHALL BE 6. COORDINATE WITH ARCHITECTURAL AND FOOD SERVICE DRAWINGS BEFORE <br /> Maximum flow rate: 9.8 GPM (37.1 I/min) POSITIONED ON WIDE SIDE OF THE STALL, AND SHALL NOT BE INSTALLED HIGHER THAN ROUGHING-IN PLUMBING FIXTURES AND EQUIPMENT SUPPLIES. PLUMBING CONTRACTOR SHALL BE 1" MINIMUM: ADAPTERS SHALL BE PROVIDED AND Store: <br /> 44" ABOVE FINISHED FLOOR. TOP OF TOILET SEAT SHALL NOT BE HIGHER THAN 19" INSTALLED ON EQUIPMENT CONNECTIONS THAT ARE LESS THAN 1". ALL DRAIN LINES 1311 E. YOSEMITE AVE. <br /> Temperature Factory Default Range -98°-120° F (37°-49°C) ABOVE FINISHED FLOOR7. THE PLUMBING SUBCONTRACTOR SHALL FURNISH AND INSTALL ALL PLUMBING SHALL BE HARD COPPER DWV TYPE WITH SWEAT FITTINGS AND SHALL BE ROUTED AS <br /> . <br /> Optional Range -98° - 185° F (37°-85°C) FIXTURES, AS IDENTIFIED ON PLUMBING FIXTURE SCHEDULE. HIGH AS POSSIBLE, AND CONFORM TO FIXTURE CONFIGURATION AND FUNCTIONS SO AS <br /> Temperature (without remote) 120° F 49°C) (factory default)or 140° F (60°C) UR: AMERICAN STANDARD 6590.503 .125 GALLON PER FLUSH, VITREOUS CHINA, WALL NOT TO OBSTRUCT OPENINGS OR SHELVES. MANTECA, CA 95336 <br /> HUNG, WASHDOWN URINAL WITH EXTENDED SHIELDS, INTEGRAL FLUSH SPREADER AND 8. VERIFY MOUNTING HEIGHT AND WATER CONNECTION SIZES TO ALL PLUMBING 5. THE PLUMBING CONTRACTOR SHALL PROVIDE SUPPLEMENTAL BRACING FOR ALL <br /> Approved Gas Types Natural or Propane(ensure unit matches gas type) TRAP, 3/4" TOP SPUD, SLOAN REGAL PRO SERIES OR ZURN AQUA FLUSH PLUS WATER FIXTURES PRIOR TO ROUGH-IN. FURNISH CUT-OUT TEMPLATES, FOR PLUMBING SAVER FLUSH VALVE. FIXTURES TO BE INSTALLED IN MILLWORK, TO THE GENERAL CONTRACTOR. Restaurant #RC529 <br /> INDIRECT KITCHEN EQUIPMENT DRAINS EXPOSED BELOW EQUIPMENT (E.G. AT <br /> Thermal Efficiency Natural Gas: 96% Propane: 96% 3-COMPARTMENT SINK AND BREADING WASH-UP STATION). SUPPLEMENTAL BRACING <br /> Service Connections Gas supply: 3/4 inch (19mm) MNPT URINAL SHALL BE DESIGNED AND INSTALLED TO MEET THE AMERICANS WITH 9. MAKE PROPER HOT AND COLD WATER, WASTE AND VENT PIPING CONNECTIONS TO SHALL CONSIST OF TWO SPLIT RING PIPE HANGERS (SIZED AS REQUIRED) Professional of Record: <br /> Cold water inlet: 3/4 inch (19mm) MNPT DISABILITIES ACT (ADA) STANDARD FOR PHYSICALLY IMPAIRED PEOPLE AND ANSI 117.1 ALL FIXTURES AND EQUIPMENT EVEN THOUGH ALL FITTINGS AND CONNECTIONS ARE CONSTRUCTED OF COPPER-PLATED CAST IRON AND CONNECTED WITH STAINLESS <br /> Hot water outlet: 3/4 inch (19mm) MNPT STANDARD. UNLESS INDICATED OTHERWISE ON DRAWINGS, URINAL SHALL BE INSTALLED NOT SHOWN. STEEL ALLTHREAD ROD. BRACING SHALL SECURE DRAIN PIPING TO KITCHEN <br /> WITH RIM HEIGHT AT 17" (MAXIMUM) ABOVE FINISHED FLOOR, AND FLUSH VALVE EQUIPMENT TO PREVENT INCIDENTAL DAMAGE TO WASTE PIPING. <br /> Isolation 8r (Pressure Relief Valves Included Isolation Valves are certified to NSF/ANSI 61 for potable water OPERATOR 44" (MAXIMUM) ABOVE FINISHED FLOOR. 10. VERIFY LOCATION OF EXISTING WATER SERVICE AND THE LOCATION/INVERTS OF <br /> SANITARY PIPING PRIOR TO INSTALLATION. 6. ABOVE GRADE SANITARY WASTE PIPING FROM ICE BINS, REFRIGERATORS AND FREEZER <br /> WH: WALL HYDRANT - ZURN Z1300-6 AUTOMATIC DRAINING WALL HYDRANT WITH INTEGRAL TO FLOOR SINKS, OPEN SITE DRAIN AND TROUGH DRAINS SHALL BE INSULATED TO <br /> Water Flow Control Water flow sensor, electronic water control and by-pass control BACKFLOW PREVENTER, REMOVABLE TEE HANDLE, 3/4" INLET CONNECTION AND 3/4" 11. LOCATE VENT STACKS NO LESS THAN 10'-0" FROM ALL FRESH AIR INTAKES. ALL PREVENT CONDENSATION. <br /> Minimum/Maximum Water Supply Pressure 20 - 150 PSI (138-1035 KPa)( recommended 60 - 80 PSI (414 -552 OUTLET HOSE CONNECTION. MOUNT 24" AFF. PLUMBING VENTS IN EXTERIOR WALLS SHALL BE OFFSET A MINIMUM OF 3'-0" 7. THE CONTRACTOR SHALL PROVIDE SERVICE AND FULLY CONNECT EQUIPMENT ITEMS, <br /> KPa)for optimal performance) BEFORE ROOF PENETRATION. FURNISH AND INSTALL ALL MATERIAL, VALVES, TRAPS, FITTINGS, STOPS, PRESSURE iou <br /> HS-1: WALL MOUNTED LAVATORY AND FAUCET SPECIFIED BY OTHERS, FURNISHED BY F.E.C. <br /> AND INSTALLED BY PLUMBING CONTRACTOR. PROVIDE ALL REQUIRED DRAINS, STOPS, 12. FURNISH AND INSTALL WATER HAMMER ARRESTORS IN ACCORDANCE WITH PDI-WH REGULATORS, AND PIPING BETWEEN EQUIPMENT AND STUB-OUT LOCATIONS TO MAKE <br /> EQUIPMENT FULLY OPERATIONAL. ROBISON <br /> Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior VALVES, FITTINGS, ETC. FOR A COMPLETE INSTALLATION. 201 AND WHERE REQUIRED BY LOCAL AUTHORITIES. WATER HAMMER ARRESTORS <br /> notice. Local, state, provincial and federal codes must be adhered to prior to installation. HS-2: SHALL BE LISTED BY A.S.S.E. STANDARD 1010. 8. PIPING SHALL BE CONCEALED IN WALLS WHEREVER POSSIBLE. STUB-OUT DIMENSIONS ENGINEERING, INC <br /> WALL MOUNTED HAND SINK WASSERSTROM - E23.SS, 2-HOLE (FAUCET/DECKSOAP) ARE FROM FINISHED WALLS TO CENTER OF STUB-OUTS OR FROM CENTER OF 1940140TH AVE W.,SUITE 302 <br /> RECTANGULAR S/S 33.5" X 20", INCLUDE S/S. KOHLER SELF-METERING FAUCET 13. UNDERGROUND PLASTIC PIPING SHALL BE INSTALLED IN ACCORDANCE WITH ASTM LYNNWOOD,WA98036 <br /> e , : 10.0137.9) - _- T ____.____..__.____;____+___+___ ___+___+___ �_____________;___+___ V), FURNISHED BY F.E.C. AND D2321, ASTM F1668, AND ALL APPLICABLE LOCAL CODES. STUB-OUT TO CENTER OF STUB-OUT. 206-364-3343 TEL <br /> - =__ ---- --------------------1------- ---•- r ............... _ <br /> _ _ _ ;....,...,...�..- K-13468-VS WITH THERMOSTATIC MIXING VALVES M <br /> "__t___t _ ________A____q____}___+_____________F____t____r________i----i----i____----g.0(3a.t) --_;_-__; ------T___;__-+___:_-__ ___;-___+___+-_-+_-_ ---+__-+_--t-__:__-----_;____ INSTALLED BY PLUMBING CONTRACTOR. PROVIDE ALL REQUIRED DRAINS, STOPS, 9. STUB-OUT LOCATIONS AND CONNECTION REQUIREMENTS ARE RELATIVE ONLY TO <br /> ===---------+ _-_;=_=-t-::+------=_-__-=-=r==_+-_-+___-_-+-==-t---�t=-=+=-_--_-;==__i--==+___+_-_ VALVES, FITTINGS, ETC. FOR A COMPLETE INSTALLATION. <br /> 14. IT IS THE INTENT OF THESE DRAWINGS TO COVER ALL WORK AND MATERIAL FOR A REI# 424-1497 <br /> 8.0130.3) -tt- _ tt- - -------- FIRST CLASS INSTALLATION. ANY EQUIPMENT, PLUMBING FIXTURE, TRIM HARDWARE ITEMIZED FOOD SERVICE EQUIPMENT AND FIXTURES. PLUMBING PLAN IS INTENDED FOR <br /> t t t * t- ROUGH IN LOCATIONS, CONNECTION POSITIONS, AND LOAD REQUIREMENTS FOR FINAL <br /> _ _________________"--, 1:::::_--4---:,-_::-4----}::: ::: :=:__F:::*::=:r::::::::,::::,_:::+:::{_:= FS. VI Y UTILIZED I T A F SPECIFICALLY <br /> + t t t t + t 1 1 + + + + t 1 + + + FLOOR SINK ZURN FD2370 PVC FLOOR SINK, 12 X 12 6 WITH DOME STRAINER <br /> AND/OR DEVICES USUALL U L ZED N HE CLASS 0 WORK NOT SPEC( IC LLY , <br /> 7.0(26.5) __+_"__t___"-------------------+---+-_ --- -------------------a--------+---+--- ---+------------r------------a----a----+--- AND FULL GRATE OPTION ARY FOR ROUGH-IN. SEE ARCHITECTS PLAN FOR ADDITIONAL REQUIREMENTS. <br /> - - - <br /> - - ..7------- ------- --- ----- <br /> - -: +---------+ T -: + + - <br /> zz.� ------ """""" --- "- THE SATISFACTORY COMPLETION OF THE WORK AS DETERMINED BY THE <br /> 6.01 ) - ------ - - : I:::: ;:::: ::: :: : :::-: :::t:=_ :::_;::::r:_ : �::: 10. - FLOOR, NOT FROM <br /> STUB OUT HEIGHTS SHALL BE MEASURED FROM THE FINISHED <br /> Q_ =_��====t===t===i========a-===-___+ --------t--- ------a----a----+---+--- ---+--------t----t--------a----a----+---+--- GWH: INSTANTANEOUS GAS WATER HEATER - RINNAI C199i WATER HEATER, WITH 15,200 ARCHITECT SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR AS PART <br /> 0) 5.0(19.0) _"t" r r t------- r t= r r r----t- ----1----r---r---t-- ---+---t----r----t---- i----t----r---r--- ) CURBS OR PADS, TO THE CENTERLINE OF THE STUB-OUT. STUB-OUTS SHALL EXTEND <br /> ;____;:___;________ ___}-___; ___-____;:==t==_=;_:__- ,----+---+--- ---+----t----t----t--------,----,--------+--- BTU/HR TO 199,000 BTU/HR INPUT RANGE. PROVIDE 2 WATER HEATERS INSTALLED IN OF HIS TOTAL WORK. <br /> 3 :+::: ::=-_:_t--t---:t::::::::i::::�::: +_ 4' BEYOND WALLS. <br /> 0 4.005.1> _ - �" ; "�""� "�" PARALLEL CONNECTION, SEE DETAIL 2/P6.1. WATER HEATERS ARE CAPABLE OF 15 GPM <br /> + r t====�_______=;------=+ "=i== t + F i i + + h -----i , + +-= TOTAL AT 50°F RISE. PROVIDE UBBINK CONCENTRIC VENTING SYSTEM COMPLETE WITH 15. ALL WORK, BOTH MATERIAL AND INSTALLATION, SHALL BE GUARANTEED FOR A - QROFESS/ONq <br /> L 3.0111.4) PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE BY THE OWNER. 11. HORIZONTAL PIPING AS EXTENDED FROM THE STUB OUT SHALL BE INSTALLED NOT D• Rpt <br /> ±::_F::_±:_:�:::::::+:_±::_±:= =_fi::_r:_+::_:::::;_,___�-:::±__±__:-===t:_+:4-4---- :::; _ ;:_t::: PVC CONCENTRIC VENT PIPE (PVC OUTER PIPE/METAL INNER PIPE), FLAT ROOF LESS THAN 6" ABOVE FINISHED FLOOR. HORIZONTAL PIPING SHALL BE BRACED AS 1S F <br /> co t t i i + + = FLASHING ASSEMBLY AND ROOF DISCHARGE TERMINATION. IN ADDITION PROVIDE RINNAI <br /> 2.0(7.6) �t- -_ REQUIRED WITH STANDOFFS THAT ALLOW FOR CLEANING ACCESS BETWEEN PIPING AND v� Z <br /> ----F----� -�--------<----�---- �-- �----�----�- ----+----�--•+---+--- --+---}----�---�-------+----�---+---+--- TANKLESS VALVE KIT COMPLETE WITH UNIONS, PURGE/DRAIN PORTS. SHUTOFF VALVES WALL. c5 - m <br /> t -t t t + + + + t + + + M 2871 <br /> - --- ------ - <br /> + +� �� F. PROVIDE <br /> y t - --1 1 - --- -- ---t <br /> 1.0 AND PRV SET LEAVING WATER TEMPERATURE TO 120 DEGREES � <br /> (38) _:_ TEMPERATURE CONTROLLER, RE: PLUMBING ROUGH-IN NOTES. <br /> 0.0 :_- 12. THE CONTRACTOR SHALL FURNISH AND INSTALL WALL AND FLOOR SLEEVES. FLOOR EXP 0-21 <br /> 0 25(13.9) 50(27.8) 75(41.6) 100 (55.6) 125(69.4) 150 (83.3) HWP: DOMESTIC HOT WATER CIRCULATOR PUMP - GRUNDFOS ALPHA1 SERIES PUMP WITH SLEEVES SHALL BE WATER TIGHT AND EXTEND 1" ABOVE FINISHED FLOOR SLEEVES <br /> SEAL SLEEVE OPENINGS WATERTIGHT. q �F <br /> delta T - Temperature Rise IF (°C) MULTI-SPEED ECM MOTOR, STAINLESS STEEL BODY, AND INTEGRAL CHECK VALVE. THROUGH PADS AND CURBS TO BE FLUSH. lF OF CAL�F�� <br /> INSTALL PUMP IN ACCORDANCE WITH MANUFACTURERS INSTALLATION INSTRUCTIONS. MATERIAL SPECIFICATIONS 13. ALL FLOOR SINKS ARE SHALL BE SET FLUSH WITH THE FINISHED FLOOR. FULLY OR <br /> O 2015 Rinnai Corporation C199i-SP 6/2015 �. r\ ALL COMPONENTS AND ADDITIONAL ACCESSORIES REQUIRED SHALL BE LEAD-FREE PARTIALLY EXPOSED FLOOR SINKS SHALL BE COMPLETE WITH TOP GRATE, TYPE AS <br /> c sus C� �� e CONSTRUCTION. PROVIDE 24 HOUR TIME CLOCK AND PROGRAM TO RUN PUMP DURING INDICATED BY FOOD SERVICE DRAWINGS. IN THE EVENT THAT LOCAL CODES REQUIRE <br /> Low Lead Content SANITATION RESTAURANT OPERATING HOURS. 1. DOMESTIC HOT/COLD WATER PIPING BELOW SLAB/DRIVES OR EXPOSED TO VIEW FLOOR SINKS SHALL BE SET ABOVE OR BELOW FINISHED FLOOR OR CURBS THE <br /> NSF/ANSI372 INSIDE BUILDING SHALL BE TYPE "L" COPPER WITH WROUGHT COPPER FITTINGS. GENERAL CONTRACTOR SHALL PROMPTLY ADVISE THE ARCHITECT AND FOOD SERVICE 08/07/20 <br /> FD-1: FLOOR DRAIN - ZURN Z-415B FLOOR DRAIN, DURA COATED CAST IRON BODY WITH WATER PIPING ABOVE SLAB AND CONCEALED WITHIN WALLS OR ABOVE CEILINGS <br /> BOTTOM OUTLET COMBINATION INVERTIBLE MEMBRANE CLAMP AND ADJUSTABLE COLLAR DESIGNER. <br /> WATER HEATER SPEC WITH 8" "TYPE B" POLISHED NICKEL BRONZE STRAINER. INSTALL FLOOR DRAIN WITH MAY BE CPVC OR PEX (WHERE PERMITTED BY LOCAL CODES). WATER PIPING Prototype: P4 EXTENDED- HV, SCHEMEA <br /> UNDERGROUND AND NOT UNDER BUILDING SLAB OR DRIVES MAY BE TYPE 1, 14. ACCESSORIES INCLUDING FAUCETS, LEVER WASTE, VALVES ETC., UNLESS SPECIFIED <br /> N.T.S. TRAP PRIMER. SCHEDULE 40, PRESSURE RATED, PVC PLASTIC PIPE WITH SOLVENT-WELDED OTHERWISE, SHALL BE SUPPLIED BY THE FOOD SERVICE EQUIPMENT CONTRACTOR AND <br /> Prototype Issue Date: 6.29.2020 <br /> FD-2: FLOOR DRAIN - ZURN Z-315 TOP VANDAL PROOF DRAIN, DURA COATED CAST IRON FITTINGS. PROVIDE 12 GA. TRACER WIRE ABOVE PIPE BELOW GRADE. INSTALLED BY THE CONTRACTOR. <br /> BODY BOTTOM OUTLET, INVERTIBLE MEMBRANE CLAMP, VERTICALLY ADJUSTABLE NICKEL Design Bulletin Updates: INCLUDED <br /> ALL DOMESTIC WATER AND CONDENSATE DRAIN PIPING CONCEALED WITHIN WALLS <br /> BRONZE TOP WITH SECONDARY STRAINER AND HINGED LOCKING COVER. INSTALL FLOOR 2. 15. GENERAL WATER PRESSURE IN THE KITCHEN AREA SHALL NOT EXCEED 50 PSI <br /> DRAIN WITH TRAP PRIMER. OR ABOVE CEILINGS SHALL BE INSULATED. INSULATION SHALL BE PLENUM RATED MAXIMUM. THE CONTRACTOR SHALL FURNISH AND INSTALL PRESSURE REDUCING Date Issued: Bulletin Number: <br /> FLEXIBLE BLACK SELF-SEAL ARMACELL TUBOLIT SS 1/2" THICK FOR COLD WATER VALVES AS REQUIRED. NOV. 2018 1 & 2 <br /> FCO: FLOOR CLEAN-OUT - ZURN Z-1400 "LEVEL TROL" ADJUSTABLE FLOOR PIPING UP 2" SIZE; FOR HOT WATER (105-1407) 1"THICK UP TO 1"PIPING, <br /> CLEAN-OUT, DURA COATED CAST IRON BODY WITH GAS AND WATERTIGHT TAPERED 1-1/2" UP TO 2" PIPING. PROVIDE SHEET METAL SADDLES AT EACH PIPE 16. PIPING FROM REFRIGERATION COILS TO CONDENSERS AND FROM COILS TO DRAINS IS <br /> THREADED PLUG AND ROUND POLISHED NICKEL BRONZE TOP ADJUSTABLE TO FINISHED HANGER. PROVIDED UNDER THE REFRIGERATION SCOPE - SEE CONDITIONS PLAN. 1ST BLDG. SUBMITTAL <br /> FLOOR. <br /> 3. ALL SANITARY, WASTE, AND VENT PIPING SHALL BE PVC SCHEDULE 40 SOLID 17. GREASE INTERCEPTORS SHALL BE SIZED, LOCATED AND INSTALLED PER LOCAL CODES. <br /> Condensing Tankiess WCO: WALL CLEANOUT - ZURN ZS1468 WITH SMOOTH STAINLESS STEEL ACCESS COVER AND WALL PIPE AND DWV FITTINGS WITH SOLVENT-WELDED JOINTS, CONFORMING TO GREASE INTERCEPTOR SPECIFICATIONS SHALL BE VERIFIED AND COORDINATED WITH THE <br /> TWO Unit Circulation AizaWCondensing wxWHastaa 2 BRONZE CLEANOUT PLUG. MATCH TO PIPE SIZE. ASTM D1784, ASTM D1785, ASTM D2665, ASTM D2564, ASTM F1866, AND NSF 14 OWNER, DESIGN TEAM, GENERAL CONTRACTORS, AND FOOD SERVICE EQUIPMENT <br /> STANDARDS. CONTRACTORS. <br /> NUIL mochankConnectin• RHY: ROOF HYDRANT - WOODFORD MODEL RHY-2MS COMPLETE WITH WOODFORD MODEL <br /> Anaerdaseasraw drain and bedoposedofaeead'mgtolocal ada. *RdartoRk-01Acces'0"06and 50HF WITH 3/4" HOSE CONNECTION AND DOUBLE CHECK VALVE, 1" INLET, 1/8" 4. ALL EXPOSED WASTE PIPING SERVING KITCHEN EQUIPMENT SHALL BE DWV TYPE 18. EXISTING PIPES MAY NEED MODIFICATION TO CLEAR NEW UTILITIES. THE CONTRACTOR <br /> Use only corrasion resistant materials for as aodesuide hem liner Model Applicability for abaraoic <br /> socbasPVC pipe orphitichmThe eoodmestedrain pip(a�gits connectiondeudis DRAIN� HOLE, EDPM BOOT, AND MOUNTING SYSTEM INSTALL PER MANUFACTURER'S COPPER TUBE ASTM B306 WITH CAST BRONZE DRAINAGE PATTERN FITTINGS AND SHALL COORDINATE WITH ALL TRADES PRIOR TO THE START OF WORK. <br /> arnare iochr ) `tee atlead 1het°m � ie <br /> ev0vtthe�nUs%(12 SOLDERED JOINTS. <br /> REQUIREMENTS. <br /> 19. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FEES, PERMITS, AND LICENSES <br /> Where d theme than am melee sized in etaaa I �i I TD: 5. GAS PIPING SHALL BE SCHEDULE 40 BLACK STEEL. LOW PRESSURE NOT FOR THE COMPLETE INSTALLATION OF HIS WORK. <br /> ynth nappraoedaemaami� local. and ii I I I TRENCH DRAIN - ZURN Z-883 6 WIDE SHALLOW TRENCH DRAIN SYSTEM. HIGH <br /> oundausaft dredut pe should beopmtothe aftnowhareThe ad L__J _J DENSITY POLYPROPYLENE STRUCTURAL COMPOSITE DRAIN CHANNEL WITH 3.5" DEPTH. EXCEEDING 5 PSIG) GAS PIPING SHALL HAVE THREADED JOINTS WITH MALLEABLE 20. THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL LOCAL AND NATIONAL <br /> REVISIONS: <br /> shoo1daotbe�wisesorodieveeuncaLCa°�p0e�etbe l IRON-BANDED FITTINGS. PIPING 2-1 2" DIAMETER AND LARGER MAY HAVE <br /> disposedofaand'mgtolocalcodes. 40 LONG SECTION WITH INTEGRAL TOP FRAME AND RADIUSED BOTTOM. FURNISHED / CODES. 1 08-07-20 1st. Bldg. Submittal <br /> r®pshould beaookolledbyanAgastat,rum orcamb.tioer � - WITH HEAVY DUTY FIBERGLASS GRATE, (2) CLOSED END CAPS, DOME BOTTOM WELDED JOINTS WITH FORGED STEEL WELDED FITTINGS. ALL GAS PIPING INSTALLED <br /> Aquaautand 7Ymer. - _ - - STRAINER AND 3" NO-HUB BOTTOM OUTLET. CONCEALED ABOVE CEILINGS SHALL HAVE WELDED JOINTS WITH FORGED STEEL 2 <br /> 21. WORK INDICATED ON THESE DRAWINGS SHALL BE COORDINATED WITH WORK BY <br /> r®pshould bedead temm�a;r�onloop amparatme. WELDED FITTINGS AS PER FUEL GAS CODE. GAS PIPING UNDERGROUND SHALL BE 3 <br /> `y MV: POLYETHYLENE PIPE AND FITTINGS, ASTM D-2513. STUB-UPS FROM ALL OTHER TRADES. <br /> map•�p•�•wbealaedrow«comemapr�.reloaawmose+he � � � � POINT-OF-USE THERMOSTATIC MIXING VALVE - ZURN ZW3870XLT-4P, WITH INTEGRAL 4 <br /> heater,supply,&ad I plunkina-Refirence theUNDERGROUND SHALL BE APPROVED PRE-MANUFACTURED ANODE-LESS <br /> x;�iHot Water System Design M.mal,p®pSizigfor Ckadatioe. CHECK VALVES AND ADJUSTABLE TEMPERATURE CONTROL. THE ASSEMBLY SHALL BE 22. WHEN ROUGHING-IN, THE TRADES SHALL BE RESPONSIBLE FOR MAKING ALLOWANCES 5 <br /> pm>,paba,rla�afb <br /> _ _ LISTED BY A.S.S.E. STANDARD 1070. INSTALL PER MANUFACTURER'S INSTRUCTIONS TRANSITION FITTING RISER ("PIGTAIL") WITH BUILT-IN 90 DEGREE BEND AND FOR VALVES, TRAPS, DISCONNECTS ETC. <br /> eratmlmaea . cl..seppq AND SET LEAVING HOT WATER TEMPERATURE TO 1057. PLASTIC COATED STEEL CONDUIT OUTER SLEEVE. PROVIDE 14 GAUGE COPPER 6 <br /> Caoa�Dramz� TRACER WIRE AND UNDERGROUND WARNING TAPE INSTALLED ABOVE 23. WATER HEATER SHALL BE INDOOR-MOUNTED, INSTANTANEOUS, GAS-FIRED, DIRECT 7 <br /> MS: MOP SINK FAUCET - ZURN Z-841M4 WITH INTEGRAL VACUUM BREAKER. UNDERGROUND PIPING. ALL EXPOSED GAS PIPING SHALL RECEIVE 2 COATS OF VENT, DESIGN CERTIFIED TO ANSI Z21.10.3 STANDARD FOR GAS-FIRED WATER 8 <br /> aatwattrsep*L= Cold Wi°uSmoy Li00 KOPPERS BITUMINASTIC COAL TAR EPDXY, BLACK, #321. HEATERS. WATER HEATER SHALL BE CONFIGURED TO OPERATE WITH NATURAL GAS <br /> -adRPZ: REDUCED PRESSURE ZONE BACKFLOW PREVENTER - ZURN WILKINS 975XL2 WITH 9 DOUBLE CHECK VALVE ASSEMBLY, INLET/OUTLET SHUT-OFF VALVES, WYE STRAINER, AND A 120 VOLT/60 Hz AC POWER SOURCE. UNIT SHALL HAVE A MAXIMUM BTU <br /> INPUT OF 199,000 BTU/HR UEF RATING OF 0.81 HOT WATER OUTPUT CAPACITY OF <br /> �c TEST COCKS AND RELIEF VALVE. INCLUDE MANUFACTURER'S AIR GAP DRAIN FITTING 7.5 GPM (507 TEMP. RISE), AND MINIMUM OPERATING FLOW RATE OF 0.4 GPM. WATER <br /> (WITH SPLASH SHIELD) TO MATCH THE ASSEMBLY. THE ASSEMBLY SHALL BE LISTED BY <br /> A.S.S.E. STANDARD 1013 AND SHALL BE U.S.C. APPROVED. THE BODY OF THE HEATER SHALL BE MICROPROCESSOR CONTROLLED AND UTILIZE A DIRECT ELECTRONIC <br /> o IGNITION SYSTEM, FULLY MODULATING GAS CONTROL VALVE, TURBINE FLOW METER, Sheet Title: <br /> REDUCED PRESSURE VALVE SHALL BE LEAD-FREE CONSTRUCTION. AUTOMATIC ELECTROMECHANICAL WATER FLOW CONTROL VALVE, AND WATER <br /> Aquastat optional for residential applications.only required for <br /> $' high-tempoommerdalapplicET-1: ZURN MODEL XT-8, 150 PSI ASME RATED, GALLON TANK VOLUME 1.0 MAXIMUM <br /> Iding Outlets ations. <br /> TEMPERATURE THERMISTORS TO MAINTAIN OUTLET WATER TEMPERATURE WITHIN +/- PLUMBING <br /> GALLONS ACCEPTANCE. INLINE MOUNTED, CARBON STEEL OUTER SHELL WITH BUTYL 2°F OF SETPOINT. UNIT SHALL INCORPORATE THE FOLLOWING INTERNAL SAFETY SPECIFICATIONS <br /> RUBBER DIAPHRAGM DESIGN, DESIGNED FOR POTABLE WATER LINES, 10-1/2" HIGH DEVICES: FLAME FAILURE LOCKOUT, BOILING PROTECTION LOCKOUT, THERMAL <br /> X 8" DIA., 5.5LBS SHIPPING WEIGHT. 3/4" PIPE CONNECTION. OVERHEAT PROTECTION, INTERNAL FREEZE PROTECTION FOR AMBIENT TEMPERATURES <br /> BOOSTER: GRUNDFOS - CRE 10-2. 25PS1 BOOST; 60GPM FLOW PER FIXTURE CALCULATION. AS LOW AS -307, AND LOCKOUT PROTECTION IN THE EVENT OF A BLOCKED FLUE.WATER HEATER SHALL UTILIZE A REMOTE TEMPERATURE THERMOSTAT CONTROLLER TO Date: 08.07.2020 <br /> WATER HEATER INSTALLATION PUMP 208V/1PHASE. 2 HP. PROVIDE AN ADJUSTABLE SETPOINT RANGE OF 907 TO 1807. WATER HEATER SHALL <br /> 21 <br /> N.T.S. HAVE AN INTERNALLY COATED COPPER HEAT EXCHANGER, WARRANTED AGAINST Project Number: RAC19024.0 <br /> MATERIAL DEFECTS OR WORKMANSHIP FOR A MINIMUM PERIOD OF FIVE YEARS FROM <br /> THE DATE OF PURCHASE. UNIT SHALL HAVE STAINLESS STEEL BURNERS, SOLID BRASS Drawn By: XXX/XXX <br /> WATER FLOW CONTROL VALVES AND SOLID BRASS INLET AND OUTLET WATER <br /> CONNECTIONS. THESE AND ALL OTHER PARTS SHALL BE WARRANTED AGAINST <br /> MATERIAL DEFECTS OR WORKMANSHIP FOR A MINIMUM PERIOD OF FIVE YEARS FROM <br /> THE DATE OF PURCHASE. <br /> Sheet Number: <br /> P6 , 1 <br /> J <br /> Q <br /> 1= <br /> G <br /> CD <br /> M <br /> fn <br />