WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1311
>
1600 - Food Program
>
PR0547032
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2021 1:32:03 PM
Creation date
8/19/2021 12:56:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0547032
PE
1625
FACILITY_ID
FA0026658
FACILITY_NAME
RAISING CANE'S #529
STREET_NUMBER
1311
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
208260080
CURRENT_STATUS
01
SITE_LOCATION
1311 E YOSEMITE AVE
P_LOCATION
04
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
197
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> z <br /> a <br /> 19 - 28 <br /> Irrigation Notes: Water Pressure Note: <br /> Contractor shall verify p.o.c. static pressure in field prior to beginning any MAWA & ETWU CALCULATIONS <br /> 1 . Install drip irrigation system per City of Manteca standards. work. Notify landscape architect for any discrepancies not similar to static <br /> pressure given by water purveyor. I <br /> 2. Verify location of water meter. <br /> psi: 46 psi <br /> 3. This plan is diagrammatic. All pipes, valves, etc. shown within paved areas <br /> are for design clarification only and shall be installed in planting areas Site Information <br /> wherever possible. Note A: Site Name RC Manteca K I E S E L • DESIGN <br /> Point of connection shall be a 1 " water meter with a 4" service line. Verify the <br /> 4. Do not install the irrigation system as indicated on the drawings when it is actual location, size and water pressure in the field prior to starting work. If Site Type Commercial <br /> obvious in the field that obstructions or grade differences exist and should any of the poc information shown on these drawing is found to be different Annual Eto (inches/yr) 51.2 <br /> e <br /> than the actual poc information gathered in the field, immediately notify the Kiesel Landscape <br /> be brought to the attention of the owner's authorized representative. p <br /> landscape architect. Should the contractor fail to verify the poc information Hydrozone or Estimated <br /> 5. Irrigation system is designed assuming a static water pressure of any changes required by low pressure or volume shall be the sole Irrigation Irrigation Hydrozone <br /> responsibility of the contractor. Planting Plant Factor (PF) ETAF (PF/IE) ETAF x Area Total Water Architecture Inc. <br /> res <br /> approximately 46 psi at point-of-connection. Prior to installation of irrigation p y Description Method Efficiency (IE) Area (sgft.) Use (gal./yr.) <br /> system, contractor shall verify pressure at point-of-connection and report <br /> any discrepancies to the landscape architect. Static Water Pressure 46 PSI Regular Landscape Areas <br /> Design Water Pressure 20 PSI 1 0.3 Low Drip 0.81 0.4 805 298 9,464 422 E Main Street <br /> 28 GPM 7 <br /> D <br /> t <br /> S <br /> Maximum System Demand . <br /> 6. It is the intent of this plan to provide adequate irrigation to all planting areas. Max2 0.3 Low Drip 0.81 0.4 25 9 294 Ventura, CA 93001 <br /> Contractor shall be responsible for making any and all adjustments to the Residual Pressure 5.30 PSI <br /> 3 0.3 Low Drip 0.81 0.4 2,356 873 27,700 <br /> irrigation system necessary to insure 100% irrigation coverage of all planting (p) 805.947.0730 <br /> areas. 4 0.3 Low Drip 0.81 0.4 509 189 5,984 <br /> Note B: <br /> 5 0.3 Low Drip 0.81 0.4 1,290 478 15,167 Jack@kieseldesign.com <br /> 7. Install the irrigation system in accordance with all local codes. Controller 'C' shall be a Hunter i-core, 12 station controller assembly installed 6 0.3 Low Drip 0.81 0.4 25 9 294 CL# 5206 <br /> in an outdoor pedestal as part of controller assembly. 9 total stations used. 7 0.3 Low Drip 0.81 0.4 60 22 705 <br /> 8. Piping installed under pathways or paved areas, through walls or footings Final location of controllers and electrical P.O.C. shall be confirmed with 8 0.3 Low Drip 0.81 0.4 415 154 4,879 <br /> shall be placed inside schedule 80 pvc sleeves of adequate size to allow free owner's authorized representative prior to commencing work. <br /> movement of the pipe in the sleeve. 9 1 0.3 1 Low Drip 1 0.81 1 0.4 10 4 118 <br /> SUBTOTALS 0 0 0 <br /> 9. Flush all lines and adjust all emitters for maximum performance. Call Estimated Total Water Use (ETWU) 64,605 RC #529 <br /> landscape architect and owner 48 hours in advance for coverage tests. Note: <br /> This design is diagrammatic. All equipment shown in paved areas is for design Maximum Allowed Water Allowance MAWA 78,495 <br /> 10. Adjust flow controls for proper performance and valve longevity. clarity only and is to installed within planting areas. Raising Canes <br /> 11 . Provide sleeving for mainline below driveways, sidewalks, and walls. Valve Location Note: ETAF Calculations Notes: Manteca <br /> 12. Irrigation lines shall be buried at the following minimum depths: Electric control valves and isolation valve locations on this drawing are Regular Landscape Areas <br /> PVC pressure mainline:18" approximate. The landscape contractor shall stake out each electrical control Total ETAF x Area 2,035 ETWU meets MAWA requirement. 1325 Yosemite Ave <br /> PVC lateral line:12" valve and isolation valve location for review and approval by owner prior to Total Area 5,495 <br /> PVC lines 2-1/2" or larger: 24" installation of all valves. Final location and exact positioning for electric control Average ETAF 0.37 Average ETAF meets requirement for this site type. Manteca, CA 95336 <br /> valves and isolation valves shall be determined by the owner. Minor <br /> 13. Total landscaped area, excluding hardscape, gravel & dg = (5,376) sf modifications of electric control valves and isolation valve locations as <br /> total area of drip = (5,376) sf or 100% requested by the owner shall be provided by the contractor at no additional All Landscape Areas <br /> cost to the owner. Failure to obtain owner's approval prior to the installation Total ETAF x Area 2,035 Calculator developed July 27, 2015. Submittals: <br /> Irrigation System Design Criteria: shall cause the contractor to make owner directed revisions at no additional Total Area 5,495 This calculator is for estimating purposes only. # DATE NAME <br /> proposed water meter, assumed 46 psi static pressure. cost to the owner. In general, unless otherwise directed by owner, all valves <br /> maximum flow = 5 ft/sec. velocity in main line pipe. <br /> shall be installed three feet from edge of hardscape, walk or curb in shrub I Sitewide ETAF 0.37 Hunter assumes no liability for use of this calculator. 1 1 07.23.20 80% Review Set <br /> planting areas. 2 08.07.20 First Submittal <br /> Proposed drip irrigation controller (hunter model i-core smart controller) HYDROZONE TAB L E <br /> includes a rain sensor for automatic shut off. <br /> Notes: HYDROZONE INFORMATION TABLE <br /> Mainline shown within paving for clarity only, actual mainline location to be a <br /> Critical Analysis minimum of 18" off adjacent hardscape and other obstacles typ. <br /> HYDROZONE* ZONE OR IRRIGATION AREA (Sq. Ft) % OF LANDSCAPE AREA <br /> Generated: 2020-08-07 VALVE METHOD <br /> DSC <br /> P.O.C. NUMBER: 01 All lateral lines with greater than five feet of elevation change shall have the king LW 1 D 805 14.65% -9ti"09SCAP# 11�'c, <br /> Water Source Information: 46 psi bros. mod. no. ksc-(xxx)-s (appropriate line size) swing check valve installed at �� s2 <br /> LW 2 B 25 0.45% �I <br /> every five (5) feet of elevation change minimum. Contractor shall verify all vt _ <br /> City of Manteca-Fire Department swing check valve locations with owner's authorized representative prior to LW 3 D 2,356 42.88% � I <br /> Jesse Jimenez <br /> (209)-456-8340 . LW 4 D 509 9.26% 9. .20 <br /> e <br /> commencing work <br /> 1 2.3131. <br /> Fbnewal Dae <br /> Note: LW 5 D 1 ,290 23.48% s? 8.7. ° �Q <br /> Contractor to verify static PSI in-field prior to beginning construction. If Irrigation sleeves shown for major street, driveway and hardscape crossings for LW 6 B 25 0.45% �OF Ca0V-0 <br /> pressure varies from that listed, notify landscape architect immediately clarity only. Contractor shall install sleeving below all paving, hardscape, etc. <br /> FLOW AVAILABLE and as directed by owner's authorized representative. LW 7 D 60 1 .09% <br /> Water Meter Size: 1" LW 8 D 415 7.55% <br /> Flow Available: 29.14 gpm LW 9 B 1 0 0.1 8% <br /> All piping, mainline and lateral, and wire shall be sleeved under paving. All Type: First Submittal <br /> PRESSURE AVAILABLE sleeves to be minimum 2x diameter of irrigation pipe sleeves. All mainline shall <br /> Static Pressure at POC: 46.00 psi be accompanied with a minimum 2-inch diameter wire sleeve. Sleeving to <br /> Elevation Change: 0 ft extend minimum 12 inches beyond paving. * Hydrozone Irrigation Method <br /> Service Line Size: 4" <br /> Length of Service Line: 20.00 ft HW = High Water Use Plants MS = Micro Spray <br /> Pressure Available: 40.22 psi Bubblers and lateral lines are shown within paving and buildings for clarity only, MW = Medium Water Use Plants S = Spray Initial Setup Date: <br /> DESIGN ANALYSIS actual location to be within planter. Bubblers shall be aligned with trees and as LW = Low Water Use Plants R = Rotor January 20, 2020 <br /> Maximum Station Flow: 7.28 gpm directed by owner's authorized representative. Confirm all layout in field with B = Bubbler <br /> Flow Available at POC: 40.22 qpm owner's authorized representative prior to commencing work. <br /> Residual Flow Available: 32.94 gpm D = Drip <br /> Critical Station: 3 0 = Other <br /> Drawn By: <br /> Design Pressure: 20.00 psi # NAME DATE <br /> Friction Loss: 0.71 psi <br /> P. Luhn 08/2020 <br /> Fittings Loss: 0.10 psi <br /> Elevation Loss: 0.00 psi <br /> Loss through Valve: 2.17 psi <br /> Pressure Req. at Critical Station: 22.98 psi <br /> Loss for Fittings: 0.00 psi ©2018 Kissel Landscape Architecture Inc:The design ideas <br /> Loss for Main Line: 3.14 psi and plans represented by these documents are the property <br /> of Kiesel Design.Use or copy is permitted by contract only. <br /> Loss for POC to Valve Elevation: 0.00 psi The use or revisions of these ideas or plans is prohibited <br /> Loss for Backflow: 1.90 psi without the written permission of Kiesel Design. <br /> Loss for Master Valve: 1.90 psi <br /> Loss for Water Meter: 5.00 psi I HAVE COMPLIED WITH THE CRITERIA OF THE ORDINANCE AND <br /> Critical Station Pressure at POC: 34.92 psi APPLIED THEM FOR THE EFFICIENT USE OF WATER IN THE <br /> Pressure Available: 40.22 psi LANDSCAPE. MWELO 492.6 <br /> Residual Pressure Available: 5.30 psi ( )' Title: <br /> R ;{111 8.7.20 <br /> JACK KIESEL, LANDSCAPE ARCHITECT#5206. DATE Irrigation <br /> Notes <br /> Sheet Number: <br /> L2m2 <br />