My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1205
>
1600 - Food Program
>
PR0505470
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2021 11:29:43 AM
Creation date
8/19/2021 3:33:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0505470
PE
1623
FACILITY_ID
FA0006792
FACILITY_NAME
DOMINOS #7940
STREET_NUMBER
1205
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1205 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REVISIONS BY <br /> GENERAL LIGHTING NOTES TITLE 24 LIGHTING MANDATORY MEASURES LIGHTING KEYED NOTES <br /> 1. LIGHTING HAS BEEN DESIGNED TO SUBSTANTIALLY COMPLY 1. LIGHTING SYSTEMS ARE REQUIRED TO HAVE THE FOLLOWING <br /> WITH STATE AND LOCAL CODES. CONTROLS O CONNECT TO CIRCUIT#A-20 SHOWN ON PG. E-1. u,40 co <br /> 2. "N/L" DENOTES NIGHT-LIGHTING FIXTURE OF SAME TYPE AS A. INDIVIDUAL ROOM SWITCHING MANUALLY OR USING AN '19 <br /> SIMILAR SYMBOLS WITHOUT"N/L" NOTATION, U.O.N. 24HR 7 DAY ASTRONOMICAL TIME CLOCK TO BE INSTALLED TO c E <br /> OCCUPANCY SENSOR. CONTROL LIGHTING CIRCUITS SO THAT LIGHTING CIRCUIT i <br /> o <br /> 3. ALL LOBBY, CORRIDOR AND RESTROOM AREA LIGHTING SHALL B. SWITCHES SHALL BE LOCATED SO THAT THE LIGHTED AREA IS ENERGIZED ONLY DURING HOURS WHEN RESTAURANT Q � c <br /> BE CONTROLLED BY THE TIMECLOCK SYSTEM, U.O.N. CAN BE SEEN OR SWITCHES SHALL BE ANNUNCIATED. IS OPERATIONAL. 2HR TWIST TIMER BY-PASS TO BE INSTALLED = x '� <br /> 4. PROVIDE FIRE-RATED GYP. BOARD ENCLOSURES AROUND ALLADJACENT TO TIME CLOCK LOCATION OR AS DIRECTED BY ii <br /> C. IN PUBLIC AREAS, SWITCHES SHALL BE MADE ACCESSIBLE OWNER. INTERMATIC#ET8015C OR EQUAL. Zw c <br /> FIXTURES WHICH PENETRATE FIRE-RATED AREAS. ONLY BY BUILDING PERSONNEL. - Z o N m <br /> 5. ALL RECESSED INCANDESCENT DOWNLIGHTS SHALL BE D. BI-LEVEL SWITCHING TO REDUCE THE CONNECTED LIGHTING J N <br /> EQUIPPED WITH THERMAL CUT-OUTS WHERE REQUIRED BY LOAD BY AT LEAST 50%. (n x '7 m <br /> CODE. E. DAYLIGHT AREAS IN ENCLOSED AREAS GREATER THAN 250 a W m° - @) <br /> 6. ALL DOUBLE-SWITCHED THREE-LAMP FLUORESCENT SQ. FEET SHALL BE CONTROLLED SEPARATELY FROM NON- � a w E <br /> FIXTURES SHALL BE SWITCHED SO THAT THE INNER LAMP DAYLIGHT AREAS. <br /> OPERATES INDEPENDENT OF THE TWO OUTER LAMPS. THREE F. DISPLAY LIGHTING SHALL BE SEPARATELY SWITCHED ON <br /> LAMP FLUORESCENT FIXTURES SHALL BE TANDEM WIRED. CIRCUITS THAT ARE 20 AMPS OR LESS. <br /> THIS APPLIES TO RECESSED AND SURFACE MOUNTED G. CEC-CERTIFIED AUTOMATIC SHUT-OFF CONTROLS SHALL BE <br /> FIXTURES WITH 10 FT. OF EACH OTHER AND TO PENDANT USED FOR THE FOLLOWING: SUBJECT OR BUILDING. <br /> MOUNTED FIXTURES WITHIN 1 FT. OF EACH OTHER. ODD 2. EXTERIOR LIGHTS SHALL BE CONTROLLED AUTOMATICALLY, <br /> FIXTURE QUANTITIES SHALL RESULT IN ONE FIXTURE WITH SERVED FROM A LIGHTING PANEL WITHIN THE BUILDING, USING <br /> (1) 2-LAMP BALLAST AND (1) 1-LAMP BALLAST. ONE OF THE FOLLOWING: PANEL WITHIN THE BUILDING, <br /> 7. ALL DOUBLE-SWITCHED FOUR LAMP FLUORESCENT FIXTURES DIRECTIONAL PHOTOCELL, ASTRONOMICAL TIME SWITCH, OFESS/O� <br /> SHALL BE SWITHCED SO THAT THE INNER TWO LAMPS ENERBY MANAGEMENT SYSTEM. �,�/ �1 <br /> OPERATE INDEPENDENT OF THE TWO GUTTER LAMPS. 3. TANDEM WIRING IS REQUIRED FOR THE FOLLOWING: ONLY FOR ��'J.S. GUMBAN <br /> 8. ALL FIXTURE TRIMS SHALL BE OF THE APPROPRIATE TYPE 1-LAMP OR 3-LAMP FLUORESCENT FIXTURES; LUMINARIES ON J No. 71 z <br /> FOR THE CEILING IN WHICH THE FIXTURE IS TO BE INSTALLED. THE SAME SWITCH; LUMINARIES LESS THAN 10' APART; XPIRES m <br /> 9. PROVIDE THREE CONDUCTORS (#12 AWG) THROUGH FLEXIBLE CONTINUOUS SURFACE MOUNTED OR PENDANT FIXTURES. 09-30-22 <br /> CONDUIT FROM J-BOX TO ALL DOUBLE-SWITCHED LIGHTING 4. AUTOMATIC LIGHTING CONTROL DEVICES SHALL BE CERTIFIED DRY <br /> CTIF, <br /> FIXTURES. BY THE MANUFACTURED TO THE COMMISSION. <br /> 10. ALL FIXTURES LOCATED IN MECHANICAL EQUIPMENT ROOMS 5. AUTOMATIC TIME SWITCHES SHALL HAVE THE CAPABILITY FOR 1 STORAGE FOFCAVSF <br /> SHALL BE MOUNTED TO CLEAR ALL MECHANICAL EQUIPMENT. THE FOLLOWING: '?' <br /> 11 ALL FLUORESCENT LAMPS AND BALLASTS SHALL BE CERTIFIED SEPARATED WEEKDAY/WEEKEND SCHEDULES; HOLIDAY <br /> TO BE MANUFACTURED TO COMPLY WITH THE APPLIANCE SHUT-OFF; 10 HOUR BACKUP POWER SUPPLY. <br /> STANDARDS FOR FLUORESCENT BALLASTS. 6. AUTOMATIC DAYLIGHTING CONTROLS SHALL HAVE THE <br /> 12. ALL FIXTURES IN CONDITIONED SPACES SHALL BE EQUIPPED CAPABILITY FOR; °SA-1 <br /> WITH STATE LISTED ENERGY SAVING BALLASTS. REDUCING LIGHTING LEVEL UNIFORMLY BY 50% FLICKER-FREE <br /> 13. LIGHTING FIXTURES SHALL BE SUPPORTED BY A MIN. OF DIMMING CONTROL; 3 MINUTE DELAY BETWEEN STEPS FOR WALK-IN <br /> NO. 12 GA. HANGERS ATTACHED TO THE GRID MEMBERS STEPPED CONTROLS; NEW DEAD BAND FOR STEPPED CONTROL; <br /> WITHIN 3" OF EACH CORNER OF EACH FIXTURE. ALSO A MIN. NEW DIVICE FAILURE ALARM FEATURE. COOLER o <br /> OF 2 WIRES ATTACHED TO THE LIGHT FIXTURES. SUPPORT 7. FLUORESCENT BALLAST AND LUMINAIRIES SHALL BE CERTIFIED 8'x16' <br /> WIRES SHALL BE ATTACHED TO STRUCTURE ABOVE. AND LISTED IN THE DIRECTORY. <br /> (REFER TO DETAIL ON REFLECTED CEILING PLAN) <br /> NOTE: CERTIFICATE OF ACCEPTANCE (LTG-1-A)AND ALL RELATED / PRE:'. <br /> ACCEPTANCE DOCUMENTS SHALL BE SUBMITTED TO THE FIELD INSPECTOR J <br /> ELECTRICAL SYMBOLS DURING CONSTRUCTION (3-COPIES). CERTIFICATE OF OCCUPANCY MAY NOT <br /> SINGLE-POLE SWITCH BE ISSUED UNTIL THESE FORMS ARE REVIEWED AND APPROVED. - <br /> SINGLE-POLE SWITCH (WITH PILOT LIGHT) <br /> 46"A.F.F.UNLESS NOTED PL 46"A.F.F.UNLESS NOTED <br /> 3-WAY SWITCH EXIT LIGHT MANDATORY LIGHTING CONTROLS <br /> 346"A.F.F.UNLESS NOTED EXIT WITH BATTERY BACK-UP 1. LIGHT SWITCHES (OR OTHER CONTROL) IN EACH ROOM §131(A). i I <br /> MT. AT 12" BELOW CEILING 2. MULTI-LEVEL CONTROL FOR LIGHTING SYSTEMS > 0.8 W/FT2§131(6). ti <br /> EMERGENCY LIGHT 3. DAYLIGHTING CONTROLS §131(C). --- co <br /> DOUBLE POLE SWITCH WITH BATTERY BACK-UP A. SEPARATE SWITCHES WHEN SKYLIT OR PRIMARY SIDELIT co <br /> DP 46"A.F.F.UNLESS NOTED MT. AT 12" BELOW CEILING ZONE > 250 FT 2. <br /> B. AUTOMATIC MULTI-LEVEL DAYLIGHTING CONTROLS WHEN SKYLIT OR Q <br /> SINGLE-POLE SWITCH EMERGENCY LIGHT 2 <br /> W/OCCUPANCY SENSOR /EXIT COMBO @ 12" BELOW PRIMARY SIDELIT ZONE > 2,500 FT . A-3,5 ■ - 0 <br /> EXIT C. CONTROLS CALIBRATED SO THAT SPACE ALWAYS MEETS OR EXCEEDS <br /> OS 46"A.F.F.UNLESS NOTED WITH BATTERY BACK-UP DESIGN FOOTCANDLES AND ELECTRIC LIGHTING IS FULLY DIMMED U <br /> WHEN DAYLIGHT IS 150 PERCENT OF DESIGN ILLUMINANCE. J TC J it W <br /> PROVIDE AS MANY 4. AUTOMATIC SHUT-OFF CONTROLS-A TIME SWEEP WITH AN OVERRIDE <br /> PER CONTACTORS AS NEEDED SWITCH OR OCCUPANCY SENSOR TO ASSURE LIGHTS ARE OFF AFTER zQ <br /> PLAN BUSINESS HOURS.§131(D). <br /> LIGHTING INTERMATIC TIME 5. DISPLAY LIGHTING IS SEPARATELY SWITCHED. §131(E) <br /> CIRCUITS CLOCK 120V 6. WHEN THE TAILORED LIGHTING METHOD IS USED TO SHOW COMPLIANCE, <br /> lE <br /> L1 L2 L3 GENERAL LIGHTING MUST BE ON A SEPARATE SHUT-OFF CONTROL FROM (n <br /> 3P LIGHTING X TIMED DISPLAY LIGHTING §131(F). KITCHEN <br /> CONTACTOR N SWITCH § ( )� Z_ <br /> 120V COIL T1 T2 T3 NL1�T1 0 o Q <br /> L -1 VOID J J U) <br /> BY-PASS TO SWITCHES <br /> �I I I I cv <br /> TWIST PER PLAN )PER PLAN LED DIMMERS <br /> TIMER <br /> LIGHTING CONTROL DETAIL L , N <br /> RED FOCAL SOFFIT <br /> O O O O O ORDER O 4' <br /> FIXTURE SCHEDULE - ---- PICK-UP <br /> REF # <br /> J (N) 2'X4' LED TROFFER <br /> A � LIGHTING 39W LAY-IN PRISMATIC <br /> Lu 2GTL4LP835 39W LITHONIA OR EQUAL <br /> J (N) & (E) 12" x 48" LED SURFACE MOUNT <br /> B VP W/PRISMATIC LENSE EX / <br /> w 2TL4 30L LP380 39W LITHONIA OR EQUAL ENTRANCE <br /> ENTRANCE <br /> zQ (N) & (E) 6" RECESSED CAN LIGHT O O O O O <br /> SIZE. 6 TRIM COLOR: WHITE <br /> C O SPECIFICATIONS: - 2800K- 1200 LUMEN - CRI 80 12W 0BB <br /> LU TYPE G MANUFACTURER: ANY VENDOR (takle outonly) / <br /> Q (N) 120 CFM EXHAUST FAN n <br /> ® TOILETROOMS IN COMMERCIAL BUILDINGS SHALL HAVE V <br /> LU 77 CFM AIR CHANGES PER HOUR. MIN. z <br /> z I- <br /> z <br /> E� PS (N) DAYLIGHT SENSOR <br /> w <br /> 0- EXIT (N) COMBINATION EXIT SIGN/EGRESS LIGHT <br /> w WITH BATTERY BACK-UP TO A MINIMUM OF 90 MINUTES <br /> z DRAWN <br /> (N) EGRESS LIGHT WITH BATTERY BACK-UP N <br /> TO A MINIMUM OF 90 MINUTES <br /> w <br /> � <br /> WALL LEGEND DATE <br /> 10 - 12 -20 <br /> (E) WALLS SCALE <br /> (N) INTERIOR PARTITION 1/4" = ONE FOOT <br /> (NON-BEARING) SHEET <br /> (N) WALK-IN WALL vvwwwvvwwvvvvvvv <br /> (MANUFACTURED) E 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.