Laserfiche WebLink
SAN J 0 A Q I I I Irl Environmental Health Department <br /> CCUN r <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Verizon Business: KINGCA 13850 N DE VRIES RD, LODI August 17, 2021 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 302 CCR 66262.34(d)(2) Failed to have all communication or alarm systems, spill control, or decontamination <br /> equipment. <br /> OBSERVATION: The facility is not equipped with the following equipment:spill control. <br /> REGULATION GUIDANCE: <br /> All facilities shall be equipped with the following, unless it can be demonstrated to the Department that none of the <br /> hazards posed by waste handled at the facility could require a particular kind of equipment specified below: <br /> (a)an internal communications or alarm system capable of providing immediate emergency instruction (voice or <br /> signal)to facility personnel; <br /> (b)a device, such as a telephone(immediately available at the scene of operations)or a hand-held two-way radio, <br /> capable of summoning emergency assistance from local police departments,fire departments, or State or local <br /> emergency response teams; <br /> (c)portable fire extinguishers,fire control equipment(including special extinguishing equipment, such as that using <br /> foam, inert gas, or dry chemicals), spill control equipment, and decontamination equipment; and <br /> (d)water at adequate volume and pressure to supply water hose streams, or foam producing equipment, or <br /> automatic sprinklers, or water spray systems . <br /> CORRECTIVE ACTION: Immediately install the following equipment: spill control. Provide a corrective action <br /> statement and supporting documentation to the San Joaquin County Environmental Health Department within 30 <br /> days. <br /> This is a Class II violation. <br /> 303 CCR 66262.34(d)(2) Failed to maintain all communication or alarm systems, spill control, or decontamination <br /> equipment. <br /> OBSERVATION:An eye wash bottle with an expiration date of 10/2016 was observed in the equipment room. <br /> REGULATION GUIDANCE:All facility communications or alarm systems,fire protection equipment, spill control <br /> equipment, and decontamination equipment,where required, shall be tested and maintained as necessary to assure <br /> its proper operation in time of emergency. <br /> CORRECTIVE ACTION: This violation was corrected on site. The expired eye wash bottle was replaced with a new <br /> bottle with an expiration date of 06/2023. <br /> This is a repeat violation, Class Il. <br /> FA0003848 PR0530695 SCO01 08/17/2021 <br /> EHD 22-01 Rev.9/16/2020 Page 4 of 5 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />