Laserfiche WebLink
S A :J O Q V I � <br /> Ipl�r Environmental Health Department <br /> COUNT <br /> Swimming Pool Official Inspection Report <br /> Facility Name and Address: LINCOLN STREET APARTMENTS, 580 N LINCOLN AVE, MANTECA 95336 <br /> #9 Ladders and Handrails <br /> OBSERVATIONS:Single and double hand rails are loose. Secure handrails today. <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed.At least one handrail shall extend from the deck to not less than a point <br /> above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111 B)Pool <br /> operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #17 Cleanliness of Pool <br /> OBSERVATIONS: I observe dirt at the bottom of the pool and black precipitation at the wall of the pool. Clean wall and <br /> bottom of the pool today. <br /> CALCODE DESCRIPTION:Pool operator shall maintain clean pool water while the pool is in use and shall not allow debris to accumulate <br /> in the pool. Pool operator shall clean the bottom, sides,and other surfaces of the pool as often as necessary to keep pool surfaces clean <br /> and free of slime and algae. (CCR 65533) <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:Pool skimmer is lacking weir gate and float valve. Provide weir gate and float valve in 1 week. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications. (CBC 31368) <br /> #35 Flow Meters <br /> OBSERVATIONS:Flow meter is not available. Provide flow meter in 1 week. <br /> CALCODE DESCRIPTION:Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br /> manufacturer's specifications. (CBC 31258) <br /> #38 Filter Cleaning and Maintenance <br /> OBSERVATIONS:The difference between the Influent and Effluent readings exceed the 10 PSI. Back wash filter today. <br /> CALCODE DESCRIPTION:All filters shall be maintained in accordance with manufacturer's specifications. (CBC 31238)Pressure gauge <br /> located on the filter shall be marked with the clean startup reading. (CBC 3125B)Each filter vessel shall be provided with valves so that it <br /> can be isolated from the recirculation system for repairs and backwashing. (CBC 31288) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: gpm Chlorine: 0 ppm Temp: ° F <br /> Cyanuric acid: <30 ppm pH: >8 Combined chlorine: ppm <br /> NOTES <br /> FA0001316 PR0360070 SCO01 08/20/2021 <br /> EHD 36-01 Rev.09/16/2020 Page 2 of 3 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />