ITEMS TO PRESERVE KEYED NOTES GENERAL NOTES
<br /> TWO (2) MERCH BAY UNITS AND ASSOCIATED SIDE 1. INDICATED EXISTING WALLS AND DOORS TO REMAIN. A. IF DURING DEMOLITION CONDITIONS ARE REVEALED
<br /> PANELS. GC TO PATCH, REPAIR, AND PREP AS REQUIRED. THAT MAY JEOPARDIZE INTEGRITY OF STRUCTURE OR
<br /> PRECLUDE FOLLOWING DESIGN INTENT, GENERAL
<br /> ❑B THREE (3) UNDERCOUNTER COOLING FRIDGES 2. INDICATED EQUIPMENT AND CASEWORK TO REMAIN. CONTRACTOR TO IMMEDIATELY NOTIFY ARCHITECT OF
<br /> PROTECT DURING DEMOLITION AND NEW WORK. RECORD AND STARBUCKS PROJECT DEVELOPMENT
<br /> ONE DIGITAL SCALE MANAGER.
<br /> 3. REMOVE EXISTING PARTITION WALLS AS INDICATED.
<br /> FD ONE DUAL BREWER B. GENERAL CONTRACTOR IS RESPONSIBLE FOR SITE
<br /> 4. REMOVE EXISTING DOORS AS INDICATED. PREPARE INVESTIGATION PRIOR TO DEMOLITION TO REVEAL FULL
<br /> FEFOUR (4) BREW SERVER OPENING FOR INSTALLATION OF NEW DOOR SHOWN IN SCOPE OF WORK. NOTIFY ARCHITECT OF RECORD IF
<br /> NEW WORK. EXISTING CONDITIONS DEVIATE FROM CONSTRUCTION ©2011 STARBUCKS COFFEE
<br /> i I TWO (2)WARMING STANDS REMAIN. PATCH AND REPAIR DOCUMENTS.
<br /> I G' TWO (2) "MASTRENA II" ESPRESSO MACHINES 5 ASINEIE ED FOR NEW NG WALL TILE OAND RELOCATED EQUIPMENT. C. REMOVE WALL COVERINGS ON EXISTING WALLS TO STARBUCKS COFFEE
<br /> MATCH EXISTING TILE AND GROUT- DID 14390 WITH REMAIN THAT FACE AREAS OF DEMOLITION. REMOVAL COMPANY
<br /> FCUP LABELER GROUT GR0008 (MAPEI 10 BLACK). LATICRETE 45 SHALL INCLUDE ANY RESIDUAL MATERIAL AFTER
<br /> RAVEN. DEMOLITION, I.E. PIECES OF WALL COVERING OR 2401 UTAH AVENUE SOUTH
<br /> NITROGEN GENERATOR (UNDER COUNTER) BACKING. REMOVAL OF ALL COVERINGS IS TO BE DONE SEATTLE, WASHINGTON 98134
<br /> 6. REMOVE EXISTING CASEWORK, HANGING DEVICES, W/O DAMAGING THE EXISTING WALL SURFACE TO 206 318-1575
<br /> AND FASTENERS AS INDICATED. REMOVE ASSOCIATED REMAIN. ALSO REMOVE WALL DEVICES AND ITEMS
<br /> ELECTRICAL AND DATA LINES NOT BEING RE-USED. MOUNTED TO WALLS.
<br /> THESE DRAWINGS AND SPECIFICATIONS ARE
<br /> 7. REMOVE EXISTING PLUMBING FIXTURES AS INDICATED. D. REMOVE ALL FLOOR MATERIALS INCLUSIVE OF SETTING CONFIDENTIAL AND SHALL REMAIN THE SOLE
<br /> CAP LINES AS NECESSARY FOR THOSE NOT BEING BEDS, SUBFLOOR MATERIAL ETC. REMOVE MASTIC TO PROPERTY OF STARBUCKS CORPORATION, WHICH IS
<br /> RE-USED. PROVIDE A CLEAN FLOOR THAT IS ACCEPTABLE TO THE THE OWNER OF THE COPYRIGHT IN THIS WORK.
<br /> SUBCONTRACTOR INSTALLING NEW FINISH MATERIAL. THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN
<br /> 8. EXISTING FIXTURES, FURNITURE, AND EQUIPMENT TO PART), SHARED WITH THIRD PARTIES OR USED IN AN
<br /> BE RELOCATED AND REUSED IN NEW WORK. PROTECT E. DEMOLITION PLANS REPRESENT APPROXIMATE MANNER ON OTHER PROJECTS OR EXTENSIONS TO
<br /> THIS PROJECT WITHOUT THE PRIOR WRITTEN
<br /> DURING DEMOLITION. LOCATION OF EXISTING WALLS TO BE DEMOLISHED. CONSENT OF STARBUCKS CORPORATION. THESE
<br /> FIELD VERIFY TYPE OF CONSTRUCTION AND HEIGHT OF DRAWINGS AND SPECIFICATIONS ARE INTENDED TO
<br /> 9. REMOVE EXISTING FIXTURES, FURNITURE, AND WALLS. PLANS DO NOT NECESSARILY INDICATE ALL EXPRESS DESIGN INTENT FOR A PROTOTYPICAL
<br /> EQUIPMENT AS INDICATED. DEMO WALLS, COUNTERS, HANDRAILS, WALL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE
<br /> PROTECTION, CLOSETS, SINKS, ETC. PRIOR TO AT ANYTIME)AND DO NOT REFLECT ACTUAL SITE
<br /> 10. REMOVE ZEPHYR EQUIPMENT AND ASSOCIATED DEMOLITION, FIELD VERIFY THAT WALLS TO BE CONDITIONS. NEITHER PARTY SHALL HAVE ANY
<br /> CONCRETE CURB. PATCH FLOOR SLAB AND TILE. REMOVED DO NOT PROVIDE SUPPORT FOR EXISTING OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT
<br /> BUILDING ELEMENTS AND EXISTING CONSTRUCTION TO STATED ABOVE)UNTIL A WRITTEN AGREEMENT IS
<br /> 11. REMOVE POS STATION AT FRONTBAR. REMAIN. NOTIFY ARCHITECT OF RECORD IF FULLY EXECUTED BY BOTH PARTIES.
<br /> DEMOLITION WALLS SUPPORT EXISTING BUILDING
<br /> 12. REMOVE METRO ESPRESSO STATIONS. ELEMENTS.
<br /> ARCHITECT OF RECORD
<br /> 13. REMOVE HANDOFF PLANE. F. DEMOLISH AND REMOVE DOORS, VINYL BASE, CONDUIT, o —
<br /> WIRING, DUPLEXES, DATA OUTLETS, CABLES, SHELVING, Ez
<br /> 14. REMOVE WARMING STATION. METAL STUD AND GYPSUM BOARD WALLS, CLOSETS, _ > o —
<br /> CABINETS, FILES, COUNTERS, WOOD MOLDING, U
<br /> 15. REMOVE BREW STATION. SHELVES AND ENCLOSURES WHERE APPLICABLE. N
<br /> L
<br /> L
<br /> 16. REMOVE CONDIMENT CART. G. VERIFY ACCESS TO THE DEMOLITION AREA, INGRESS
<br /> p AND EGRESS ROUTES FOR MATERIAL AND EQUIPMENT mcg arch i t e c u r e
<br /> U WITH LICENSEE.
<br /> 15635 Alton Parkway, Suite 100, Irvine, CA 92618
<br /> 06
<br /> H. PROTECT EXISTING FLOORS, WALLS AND CORNERS TO H. 949.553.1117 F: 949.474.7056
<br /> REMAIN ALONG WORK ACCESS ROUTES.
<br /> ~I I. CONTAIN DUST AND DEBRIS WITHIN THE DEMOLITION ARCHITECT STAMP
<br /> SED ARC
<br /> 00 AREA.AREA. G��AGE Wr
<br /> o0 J. GENERAL CONTRACTOR SHALL PERFORM WORK IN A 0
<br /> X MANNER THAT DOES NOT DAMAGE THE EXISTING
<br /> STRUCTURE. DEMOLITION SHALL NOT COMPROMISE - 1839
<br /> THE STRUCTURAL INTEGRITY OF ANY WALLS, FLOORS, 1
<br /> NCEILINGS, SUPPORTS, STRUCTURE, ETC. TO REMAIN.
<br /> N K. ALL DEMOLITION MATERIALS AND DEBRIS SHALL BE F CALIF-()
<br /> DISPOSED OF ACCORDING TO FEDERAL, STATE AND
<br /> LOCAL REGULATIONS.
<br /> IL
<br /> L. AT LOCATIONS WHERE EXISTING WALLS ARE TO BE
<br /> > REMOVED NEAR EXISTING WALLS TO REMAIN,
<br /> 9 9 PERFORM DEMOLITION WITHOUT DISTURBING EXISTING
<br /> 1 g ELEMENTS TO REMAIN. WALLS TO REMAIN SHALL BE
<br /> p INTACT AND HAVE A NEAT SURFACE.
<br /> c'� 0 M. REFER TO "ITEMS TO BE PRESERVED" LIST FOR ITEMS
<br /> THAT SHALL BE SALVAGED FOR RELOCATION. VERIFY
<br /> oil I F C> �1 2 WITH LICENSEE FOR ON SITE STORAGE LOCATION OF
<br /> N 13 �I � II �I SALVAGED ITEMS.
<br /> O C:
<br /> _ I LJ _ ____�_� N. DAMAGED FIREPROOFING SHALL BE REPAIRED/ �
<br /> 0 7 �— /� V REPLACED TO MATCH EXISTING ORAS PER CODE.
<br /> 75 J -�4 0
<br /> `" � IIS _ � I --� g 2 O. THE GENERAL CONTRACTOR SHALL DEMOLISH ANY W O
<br /> / EXISTING ABANDONED VOICE/DATA CABLING AND DEAD
<br /> I _7U 7 r 7 7 I // 2 OR NON-USE ELECTRICAL LINES BACK TO PANEL. ALL O v� 0 co~
<br /> >� (2) G 8 III 8 B RECEPTACLES NOT RE-USED ARE TO BE REMOVED, U)
<br /> 6 PATCHED, AND PAINTED. W NN
<br /> " U
<br /> W Ld_ Ln
<br /> � 17)
<br /> 0 0III IIi
<br /> I 12 11 9 O P. REMOVAL OF LOW VOLTAGE EQUIPMENT PERTAINING Q Q� p (p Q 0
<br /> �1 III �� 8 B TO DATA/COMMUNICATIONS AND TELEPHONE SHALL BE Z Q O U O
<br /> > Ill VERIFIED BY THE LICENSEE AND/OR ARCHITECT OF _ >
<br /> U 7 Ni \J 6 RECORD PRIOR TO REMOVAL. W (� � (� U
<br /> 11 9 _ I I � J Q. LABEL ALL EXISTING ITEMS THAT ARE TO BE PRESERVED O � O Ca
<br /> /// l� 1 C� L 0
<br /> 3 g 9 10 _ --- III \ /� J (ABOVE) AND PROPERLY STORED FOR RE-INSTALLATION. a a U
<br /> 11* 1
<br /> 7, _4 AIV , � L___ C�7// STORE #: 8981
<br /> 0 16 6 1 --- T--7- 6 9 7 ' �/° 0 1 PROJECT #: 23870-070
<br /> — —
<br /> m 8 A B 8 1 �/ 5 15 I \�// /
<br /> CASEWORK CONCEPT:
<br /> \ / I/ _ 111
<br /> �I �� �� , 11 — 1 11 4 6 /9 7 8 /�I L ISSUE DATE: 02-23-2021
<br /> 00 ri fel 1 \ / 1 \ / 1 1 1 11 3 �—� / 1 1 __ — 2 (ABOVE) PROGRAM MANAGER: <DESIGN MANAGER>
<br /> —V —V— �'' 1 1 1 II \ 14 9 I / STORE DESIGNER: JESSICA RAMOS
<br /> C\ILE}�__ � 111 11 \\ 1 _1 __�_- - ,�o LEGEND
<br /> T4LEED(j)AP: N/A
<br /> _ A° ---_ ---= CHECKED BY: <CHECKED BY>
<br /> o IIII —�� MATERIAL TO BE DEMOLISHED
<br /> lll�_J IIS __ MCG PROJECT#:
<br /> 11 % —� —JC C ® — MATERIAL TO BE PRESERVED FOR MCG PROJ. MANAGER:
<br /> FUTUREREUSE
<br /> - MCG PROJ. SPECIALIST:
<br /> 2
<br /> 0 1 ILL 2 H E (2) EXISTING WALL TO REMAIN
<br /> �
<br /> 2 (ABOVE) (2)
<br /> Revision Schedule 1 F
<br /> 0 1 Rev Date B Description
<br /> EXISTING COLUMN TO REMAIN Y p
<br /> N
<br /> Z
<br /> iio:
<br /> 0
<br /> 75 SHEET TITLE:
<br /> W
<br /> DEMOLITION FLOOR
<br /> N
<br /> N
<br /> PLAN
<br /> SCALE:AS SHOWN
<br /> DEMOLITION PLANO N� SHEET NUMBER:
<br /> co
<br />
|