Laserfiche WebLink
SAN JOAQUIN PUBLIC HEALTH SERVICES ENVIRONMENTAL HEALTH SWIMMING POOL PROGRAM <br />1601 East Hazelton Ave., P.O. Box 2009, Stockton, CA 95201, 12091 468-'aAln <br />SWIMMING POOL PLAN CHECK SHEETS <br />A. Poot Construction (2-9011) <br />1. Plana for the pool shall be drawn to a scale of 1/4 in. to 1 ft. and for the pool <br />equipment rocs 1 in. to 1 ft. <br />2. Reinforced concrete or equivalent. <br />3. The finish color shalt be white. <br />4. Pool free from projections or recessed areas. <br />8. Geometry for pools without Diving Boards, Fig. 2-9013(a)(3). If diving boards are present, <br />see 2-9013 8 9017 <br />1. Max radius at shallow end is 1 ft. <br />2. Max. depth at shallow end is 3 1/2 ft. <br />3. Max. slope frw shallow end is 1:10. <br />4. Max. slope frac slope break to drain is 1:3. <br />S. Min. springline around pool is 2 1/2 ft. <br />6. Min, width at drain is 15 ft. <br />7. Min. length for pools less than 6 ft. deep is 15 ft. <br />8. Safety rope fasteners (flush mounted) required at 4 1/2 ft. when there is a break in slope. <br />9. Dimnsional construction tolerance is + 2 in. <br />10, oimensional tolerance on mradjustable perimeter overflow systems (gutters) is + 1/8 in. <br />11. Drainable through main drain at deepest point of pool. - <br />C. Inlets (2-9042) <br />1. Two inlets firpi 10,000 gals., ar4.3 for each 10,000 gals. thereafter. <br />Ho.required. No.provided. <br />l [,i Min. 18 in. below waterline, min. 10 ft. apart. <br />Protrude max. 1 1/4 in. into pool and be adjustable in direction and flow to cause a <br />circulatory movement to the water. _ <br />4.1� 'Dne floor inlet/10,000 gals. if pool wider than 40 ft. <br />id'ANO. floor inlets required . No. provided <br />0. Skimmers (2-9042)(pool area not over 5000 sq.ft.) <br />1. Approved type, property located with respeot to prevailing winds and circulatory water movement. <br />2. One skinnier for each 500 sq.ft. or fractional part. No. required ? - (max. of 10). <br />No, provided l <br />3. Min. 75X of required flow. <br />4. Gate valve. Accessible for operation and repair. Labelled. Not in deck. <br />5. Equalizer line with wall safety cover, float valve, check valve, rubber -a- rings, weir. <br />E. Recirculation (2-9031 and 9033) <br />1. Max. flow velocities on inlet piping: PVC - 10 ft./sec. and copper - 8 ft./sec. (preferably <br />7 ft./sec. for both), flexible PVC - 5 ft./see. Use Nillia,ns and Hazen Chart for L and 2. <br />Y Inlets TPR Pipe Size -Material Velocity ft./sec. Friction Loss -ft. <br />6 <br />5 <br />4 <br />3 ` <br />2 <br />1 <br />Heater copper <br />External bypass required if TPR exceeds heater rating.Size bypass_i n. Bypass valve_ <br />2. Max, flow velocities on suction piping: PVC and copper - a ft./sec. (preferably <br />7 ft./sec. for both), flex - 5 ft./sec. <br />d Skinners 75% TPR Pipe Size -Material Velocity ft./sec. Friction Loss -ft. <br />4 75v}p <br />3 <br />2 7'I <br />1 <br />100% TPR <br />Main drain <br />All items on page completed <br />