My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0084095_SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HUTCHINSON
>
9839
>
2600 - Land Use Program
>
SR0084095_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/7/2021 10:46:48 AM
Creation date
9/7/2021 10:40:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0084095
PE
2602
STREET_NUMBER
9839
Direction
E
STREET_NAME
HUTCHINSON
STREET_TYPE
RD
City
MANTECA
Zip
95337
APN
25724067
ENTERED_DATE
8/18/2021 12:00:00 AM
SITE_LOCATION
9839 E HUTCHINSON RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Cr �VLalues and Assumptions <br /> 900 gpd X=258d/ (From water Provision Declaration)=232,200 gals=total W W/yr=31,043 cu ft = 0.307in/yr <br /> 27.9 Ac x 43,560 sq ft/Ac x(1 ft/12 in.) <br /> Nw =62 mg N/L <br /> d = Assume 20% due to the fine-grained soil at the soil-effluent interface. <br /> R = 3.6 in/yr. <br /> Nb= Assumed to be 0.1 ppm NO,-N <br /> 0.307 in/yr(62 mg N/L) 0 - 0.20)+(3.6 in/yr x 0.1 my,/L) <br /> Nr = (0.307 in/yr+3.6 in/yr) <br /> Nr = 4.0 ppm as nitrate-nitrogen (NO3 N)or 17.8 ppm as nitrate(NO3) <br /> The calculated nitrate loading concentration in the recharge effluent from all nitrogen sources <br /> within the subject APN will to be 60%under the Maximum Contaminant Level limit for nitrate in <br /> drinking water, and is 2.5 ppm under the existing nitrate concentration in the on-site well water. <br /> IV. WASTEWATER DISPOSAL SYSTEM: <br /> OPERATIONAL PARAMETERS <br /> Septic Tank Sizing <br /> Influent from the proposed four Unisex Restrooms will gravity flow into a 2,000 gallon septic tank. <br /> The tank should be pumped on a prescribed interval basis depending on direct observations; e.g., <br /> every six months to every three years, depending on sludge/scum accumulation to be determined <br /> by a septic system contractor. <br /> Septic Tank Hydraulic Detention Time for the Septic Tank <br /> Detention Time=2 000ag 1 septic tank capacity x 0.70(30%volume lost to sludge/scum accumulation) <br /> 1.5 (Peaking Factor)x 900 gals/day ADF <br /> Detention Time = 1.0 days. The typically acceptable detention time is 1.0 days. <br /> Therefore, a 2,000 gallon septic tank is appropriate. <br /> Primary and 100% Replacement Filter Bed Areas for the proposed Four Unisex Restrooms: <br /> The filter bed area is calculated by the procedure described in EHD Document 42-01-004 <br /> Calculation Requirements for Commercial Septic Systems: <br /> Base Tank Capacity (BTC) = 1,200 gals <br /> Lineal Feet of Leachline (LFLL) = 1,200 BTC + 900 ADF from six Unisex Restrooms x 0.200 Soil <br /> Factor based on a sandy loam soil = 420 LFLL <br /> Filter Bed Area=420 LFLL x 3 (Sandy Loam Soil Factor)= 1,260 square ft, or 36 ft square. <br /> Sheet 2 of 26 from JToste Engineering illustrates the orientation of the proposed OWTS. <br /> However, the following changes are noted: <br /> 7 <br /> Chesney Consulting <br />
The URL can be used to link to this page
Your browser does not support the video tag.