Laserfiche WebLink
SYSTEM SET-UP REPORT (Page 2) <br /> T 4:LUB-30 30 OILT' r:LUB-32 H'lDRAULIC 0 2:1 .5 DIESEL <br /> T 3:WO-7 USED OIL PRODUCT CODE 4 PRODUCT 0S 1) <br /> 6 <br /> PRODUCT CODE 3 THERMAL COEFF :.000470 THERMAL COEFF :.000470 TYP:2,0,'3,01N FIBERGLASS <br /> THERMAL COEFF :.000440 TANK DIAMETER 89.00 TANK DIAMETER 89.00 2,0IN DIA LEN: 60 FEET <br /> TANK. DIAMETER 72.00 TANK PROFILE LINEAR TANK. PROFILE : LINEAR 3.0IN DIA LENT: uFEET <br /> TANK PROFILE 4 PTS FULL VOL 2435 FULL VOL : 2435 SHUTDOWN RATE: 3.0 GPfi <br /> FULL VOL 2319 LOW PRESSURE SHUTOFF:NO <br /> 54.0 INCH VOL 1965 LOW PRESSURE 0 PSI <br /> 36.0 INCH VOL 1229 FLOAT SIZE: 3.0 IN. FLOAT SIZE: 3.0 IN. <br /> 18.0 INCH VOL 467 TANK: NONE <br /> WATER WARNING 1 .0 WATER WARNING 1.0 SENSOR: NON-VENTED <br /> FLOAT SIZE: 4.0 1N. HIGH WATER LIMIT: 2.0 HIGH WATER LIMIT: 2.0 PRESSURE OFFSET: O.OPSI <br /> MAX OR LABEL VOL: 2435 MAX OR LABEL VOL: 2435 <br /> MAX OR LABEL VOL: 2319 OVERFILL LIMIT 90% OVERFILL LIMIT 90%« <br /> OVERFILL LIMIT 90 2151 2191 <br /> 2087 HIGH PRODUCT 95% HIGH PRODUCT 90% <br /> HIGH PRODUCT 95% 2313 2191 <br /> 2203 DELIVERY LIMIT 10% DELIVERY LIMIT 10% <br /> DELIVERY LIMIT 1% 243 243 <br /> 23 <br /> LOW PRODUCT 500 LOW PRODUCT 500 <br /> LOW PRODUCT 0 LEAK ALARM LIMIT: 99 LEAK ALARM LIMIT: 99 <br /> LEAK ALARM LIMIT: 10 SUDDEN! Lt1s2 LIMIT: 99 SUDDEN LOSS LIMIT: 99 <br /> SUDDEN LOSS 1.I11IT: 20 TANK TILT 0.00 TANK TILT 0.00 G 3'UNLEADED <br /> TANK TILT 0.00 <br /> MANIFOLDED TANKS MANIFOLDED TANKS TYP:2,0;3.0IN FIBERGLASS <br /> MANIFOLDED TANKS T#: NONE TO: NONE 2,OIN DIA LEN: 60 FEET <br /> T#: NONE :3,0IN DIA LEN: 0 FEET <br /> DELIVERY DELAY 1 1°1I N! DELIVERY DELAY 1 MIN SHUTDOWN RATE: 3.0 GFH <br /> STICK OFFSET 0.00 STICK OFFSET 0.00 LOW PRESSURE SHUTOFF:NO <br /> LEAK MIN PER1d,IDI0: 0% LOW PRESSURE 0 PSI <br /> 0 <br /> TANK: NONE <br /> LEAK HIN ANNUAL : 0.`•« SENSOR: NON-VENTED <br /> 0 PRESSURE OFFSET: O.OPSI <br /> PERIODIC TEST TYPE <br /> STANDARD <br /> ANNUAL TEST FAIL <br /> ALARM DISABLED T 5:LUB-31 15-40 OIL <br /> PRODUCT CODE 5 LEAK TEST METHOD <br /> PERIODIC TEST FAIL THERMAL COEFF : .000470 - - - - - - - - - - - - <br /> ALARM DISABLED TANK DIAMETER 89.00 TEST ON DATE : ALL TANK <br /> TANK PROFILE LINEAR JAN I. 1996 <br /> GROSS TEST FAIL FULL VOL 2435 START TIME : DISABLED <br /> ALARM DISABLED TEST RATE :0.20 GAL/HR <br /> DURATION HOURS LINE LEAK LOCKOUT SETUP <br /> ANN TEST AVERAGING: OFF FLOAT SIZE: 3.0 IN, TST EARLY STOP;DISABLED - _ - _ - - - _. <br /> PER TEST AVERAGING: OFF LOCKOUT SCHEDULE <br /> WATER WARNING 1 .0 LEAK TEST REPORT FORMAT DAILY <br /> TANK TEST NOTIFY: OFF HIGH WATER LIMIT: 2.0 NORMAL START TIME: DISABLED <br /> TNK TST SIPHON BREAKOFF MAX OR LABEL 'VOL, 2435 STOP TIME DISABLED <br /> OVERFILL LIMIT 90% <br /> DELIVERY DELAY 1 MIN 2191 <br /> STICK OFFSET 0.00 HIGH PRODUCT 95% <br /> 2313 <br /> DELIVERY LIMIT 10% <br /> 243 <br /> LOW PRODUCT 500 <br /> LEAK ALARM LIMIT; 99 <br /> SUDDEN LOSS LIMIT: 93 PRESSURE LINE LEAK SETUP <br /> TANK TILT 0.00 - - - - - - - - - - - - <br /> MANIFOLDED TANKS <br /> T#: NONE 0 1 :5 HP DIESEL <br /> DELIVERY DELAY 1 MIN TYP:2.0,-3.0IN FIBERGLASS <br /> STICK OFFSET 0.00 2.0IN DIA LEN: 0 FEET <br /> 3,0IN DIA LEN: 90 FEET <br /> SHUTDOWN RATE: 3.0 GPH <br /> LOW PRESSURE SHUTOFF:NO <br /> LOW PRESSURE 0 PSI <br /> • TANK: NONE <br /> SENSOR: NON-VENTED <br /> PRESSURE OFFSET: O.OPSI <br /> ©2018 Walton Engineering,Inc. <br />