Laserfiche WebLink
9 ARcy��Fc' <br /> GYP.BD.EACH SIDE OVER ROBERT J. <br /> FRAMING-SEE FLOOR ACCIARRI <br /> PLAN FOR WALL TYPE * No. C-32106 <br /> CONDITION <br /> August 31, 2021 <br /> TRACK GAUGE TO 0.145"x 1 1/4"MIN.HILTI AL DATE <br /> MATCH VERTICAL FASTENERS AT 16"O.C. <br /> STUDS U.N.O.W/ MAX. <br /> MIN.(2)#8 SCREWS HOLD GYPSUM BOARD <br /> EACH STUD 1/4"MAX.A.F.F. INFILL <br /> W/FLEXIBLE SEALANT <br /> (E)CONC.FLOOR ' <br /> — v o� <br /> Z <br /> o� <br /> 0 <br /> U) �N U <br /> O co c/> <br /> �U U <br /> E STUD WALL CONNECTION TO FLOOR 7 (� J <br /> L <br /> SCALE: 3" = 1'-0" W (,M <br /> =3L co <br /> QLO 3: <br /> METAL STUD oCO <br /> PER WALL TYPE = r , a)N <br /> 1 2 3 4 5 6 7 8 9 10 11 12 13 1a is TRADE READY SPAllER — o <br /> 0 9200 SPACING BAR ti <br /> W <br /> � o <br /> LU <br /> U) Q <br /> I QU_ <br /> (aj oNOTE: <br /> b U �0 INT.WALLS ARE COMPOSITE <br /> o � a WALLS W/SHEATHING ON BOTH <br /> U', o U_ SIDES.TYPICAL CONDITION <br /> INVOLVES A DUSTCAP FOR TOP <br /> OF WALL© I I ® I <br /> THIS DETAIL CING.ONLY E <br /> F A CONDITION <br /> OCCURS WHERE SHEATHING IS <br /> NOT USED OR TOP OF WALL IS <br /> NOT BRACED BY A DUSTCAP OR <br /> STRUCTURE. <br /> o <br /> L0 <br /> D TYPICAL BRACING DETAIL <br /> SOLAR READY AREA <br /> 6,600 SF — — — - SCALE: 3" = 1'-0" ^ z0 z <br /> DUST CAP: UO <br /> 18 GA 6"METAL JOIST @ 16"O.C.W/5/8"PLYWOOD ON 0 Z <br /> INTERIOR SIDE TOP SIDE. U) U Z <br /> OF WALL PROVIDE(2)DOUBLE JOISTS AND DOUBLE WALL STUDS Z O <br /> EA.END UNDER EQUIPMENT OVER 250 LBS. Q <br /> Uj U-1 <br /> _ LU <br /> � Q <br /> Q v, <br /> - � QZ <br /> CEILING MAY OCCUR.SEE O <br /> REFLECTED CLG PLAN AND WALL ASSEMBLY- ll�-- <br /> FINISH SCHEDULE FOR MORE SEE PLANS FOR >_H LIJ <br /> INFORMATION. WALL TYPE Q m <br /> — SCHEDULE AND w O <br /> LOCATIONS. O C)� <br /> I I I WALL ASSEMBLY- <br /> SEE PLANS FOR INTERIOR ROOM. <br /> Z W <br /> WALL TYPE SEE PLANS. O_ LU <br /> SCHEDULE AND a <br /> — D3 LOCATIONS. w <br /> O C/) <br /> C DUST CAP SECTION z <br /> 00 <br /> U O <br /> " SCALE: 3/8" = 1'-0" U) � <br /> = w <br /> zLU w <br /> B.O.DECKING OR Q) <br /> Z:) � <br /> �c STRUCTURE %Zft- U LL <br /> O O <br /> o w <br /> SLIP TRACK BY = Uj <br /> 'FIRE TRAK'OR EQUAL LU N <br /> TOP TRACK Q O <br /> 5/8"'FIRE RATED' <br /> GYR BOARD <br /> ul Q <br /> B � � <br /> METAL STUD,CUT 1.5" DRYWALL SCREWS <br /> SHORT OF I DECK,SEE WALL I I I I I I I I I I I I I I <br /> TYPES FOR STUD SIZE 2 <br /> g FIRE-RATED SLIP TRACK DETAIL <br /> SCALE: 3" = 1'-0" <br /> Z <br /> ROOF PLAN01 <br /> "' w SLIPTRACK RUNNER <br /> � J <br /> SCALE: 1/16"=1'-O" B.O.DECKING OR Uj <br /> STRUCTURE #8 WAFERHEAD <br /> 10 FRAMING SCREW <br /> TOP TRACKl< <br /> (TYP.) <br /> LEGEND DRYWALL SCREWS REVISIONS <br /> 5/8"GYP.BOARD <br /> METAL STUD CUT SHORT <br /> 4'-0"x 4'-0" ROOFTOP OF DECK,SEE WALL <br /> SKYLIGHTS UNIT TYPES FOR STUD SIZE <br /> q SLIP TRACK DETAIL <br /> SCALE: 3" = 1'-0" <br /> N <br /> 0 H H <br /> m W W <br /> 0 <br /> W W O OU <br /> cn H H <br /> � U U <br /> 3 A B C C.1 D D.3 E F F.1 G H J <br /> T.O.SIGN WALL W N o N <br /> ELEV.:21'-2"+/- Q `r o 0 <br /> 0 <br /> • MC10X15.3 W/1/2"x 61. <br /> )A307 GRADE ELEV: 14'-114tN M "d- ti <br /> SPECIAL INSPECTIONS(CBC TABLE 1705.3) THREADED RODS( T.O.ROOF BO DECK — LO (D 00 m <br /> " <br /> 1'0" @ 16"O.C.AND(2)AT EA.END- ELEV: 19'-5"+/- BO BEAM BO PURLIN TO COOLER/FREEZER 10'-0 3/8" <br /> REQUIRED SPECIAL INSPECTIONS AND TESTS c� EPDXY RODS IN PLACE(4"MIN. B/PURLINS ELEV: 11'-11" ELEV: 14'-2" BO PURLIN <br /> OF CONCRETE CONSTRUCTION \ EMBED),W/SIMPSON,"SET XP" ELEV: 18'-5" BO BEAM ±3'6" ±2'-2° ELEV: 13'5" <br /> aEPDXY,PER MANUF. ICC-ES ELEV: 12'5" CLR.@ PURLINS CLR.@ BEAM BO BEAM BUILDING CROSS <br /> Of <br /> TYPE: CONTINUOUS AND PERIODIC U_ z EVALUATION REPORT,ESR-2508 ELEV: 12'-1" <br /> _j w <br /> 4. INSPECT AND TEST ANCHORS O o X BO PURLIN <br /> SECTIONS & DOCK <br /> POST INSTALLED IN HARDENED CONCRETE o GRIND OUT EXPOSED SALES ELEV: 10'-2" DETAILS <br /> MEMBERS. 0 REBAR.SACK AND <br /> C? PATCH FOR CLEAN COOLER <br /> INSPECTIONS TO BE PROVIDED PER ACI 318: FINISHED SURFACE <br /> 17.8.2.4 FREEZER FOR PERMIT DATE: 11/06/2020 <br /> (E)FINISHED FLOOR FINISHED FLOORL - <br /> ELEV.:0'-0" JOB NO. 20263 <br /> 10'-0" CORRIDOR J RESTROOM <br /> K'F'*#N WALL OPENING DETAIL BUILDING SECTION A� 501 <br /> SCALE: 3/32" = 1'-0" <br /> SHEET NO. <br />