My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1015
>
1600 - Food Program
>
PR0162377
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/9/2021 10:05:42 AM
Creation date
9/8/2021 4:10:43 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0162377
PE
1618
FACILITY_ID
FA0022621
FACILITY_NAME
RESTAURANT DEPOT EXPRESS
STREET_NUMBER
1015
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
07523039
CURRENT_STATUS
01
SITE_LOCATION
1015 W HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
J <br /> EXTERIOR WALL COORDINATE OPENING SIZE W/ SE0 ARCy���� <br /> SET 2"LEG IN SEALANT 2" REFRIGERATION CONTRACTOR 2" <br /> &MECHANICALLY (OPENING TO OCCUR IN EXT WALL SYSTEM) �, ROBERT J. <br /> FASTEN TO STRUCTURE ACCIARRI <br /> UTILIZING TAP CONS LINE OF OPENING LINE OF OPENING * No. C-32106 <br /> OPENING FOR <br /> SLOPE TOP OF REFRIGERATION LINES August 31, 2021 <br /> TO BE DETERMINED. <br /> AL D <br /> GUARD AWAY FROM ATE <br /> 9 O�� <br /> STRUCTURE N VERIFY EXACT SIZE IN <br /> FIELD <br /> SET LEGS IN SEALANT& METAL RAIN GUARD <br /> RAIN GUARD MECHANICALLY FASTEN FABRICATED FROM 20 GA. <br /> BOTTOM OF OPENING TO STRUCTURE W/TAP GALVANIZED SHEET METAL <br /> @ 10'-6"A.F.F.-PIPE CONS PAINTED TO MATCH <br /> METAL SCREEN <br /> OPENING TO OCCUR 3A ADJACENT WALL . <br /> 1'-4" IN EXT WALL SYSTEM <br /> = U oN <br /> �00 <br /> I _ Z <br /> :I-NT <br /> _ �� <br /> r3A' RAIN GUARD SECTION DETAIL 3 RAIN GUARD PLAN DETAIL = <br /> I I _ .. 00 <br /> REFRIGERATION EQUIP.-SEE <br /> �// -N U <br /> SCALE: 1/2"=1'-0" - SCALE: 1/2"=1'-0" v/ o x cUii <br /> ao REFRIG.DWGS. FOR ADDITIONAL _ _ Y U_ <br /> M �v�j INFORMATION-COORDINATE <br /> CONDENSER UNIT TO BE ca <br /> SIZE W/SHOP DWGS. LOCATED OUTSIDE OF CANOPY J <br /> cz <br /> TO MAINTAIN AIR FLOW.VERIFY WNt <br /> �M� <br /> PARKING SPACE IDENTIFICATION SIGNS SHALL BE REFLECTORIZED WITH ALOCATION IN FIELD. Z3— m <br /> MINIMUM AREA OF 70 SQUARE INCHES(45,161 SQ.MM.)AND INCLUDE THE Q N <br /> INTERNATIONAL SIGN OF ACCESSIBILITY IN WHITE ON A BLUE BACKGROUND. EXISTING CANOPY EXISTING- _ = o <br /> ADDITIONAL LANGUAGE OR AN ADDITIONAL SIGN BELOW THE INTERNATIONAL 3x6 L 16 GA.ATTACHED COLUMN,TYP. CANOPY ABOVE L cfl <br /> SYMBOL OF ACCESSIBILITY SHALL STATE"MINIMUM FINE$250".SIGNS SHALL BE f� REFRIGERATION _ a)TO REFRIGERATION <br /> A MINIMUM OF 80 INCHES(2,032 MM)ABOVE THE FINISH FLOOR OR GROUND EQUIPMENT A ION#10 EQUIPMENT EXISTING 0 a� <br /> SURFACE MEASURED TO THE BOTTOM OF THE SIGN. SCREWS.ATTACHED CANOPY ABOVE ti <br /> +19-0 TO BEAM W/1/2"HILTI ATTACH BEAM TO CONC.W/3/8"HILTI KBTZ w/ z - <br /> 3'0" A325 BOLTS. 2 1/2"MIN.EMBEDMENT.LOCATE PER PLAN o o z N (D 0 <br /> EE <br /> VIEW BELOW. ICC ESR-1917-SET BEAM LEVEL Q w 3A <br /> ( 1 �` VAN ACCESSIBLE SPACE-SEE REQUIREMENTS W12 x 40 ON SHIMS AND GROUT FILL BETWEEN BEAM ¢ ao W <br /> FOR TYPICAL HC PARKING SIGNAGE.SIGN TO AND EXISTING SLAB C a > oz <br /> LU <br /> O° 0 1 E. 0 <br /> INCLUDE ADDITIONAL LANGUAGE WITH THE `' <br /> EMPLOYEE ENTRY ROUTE o +1 (E)CONC.SLAB GROUT SPECIFICATION: <br /> MS <br /> DESIGNATION"VAN ACCESSIBLE". "NONMETALLIC,SHRINKAGE RESISTANT <br /> Fl - LL CL n n GROUT:ASTM 1107,FACTORY-PACKAGED,NONMETA 0io <br /> I <br /> °MAIN ENTRY ROUTE <br /> AGGREGATE GROUT NONCORROSIVE AND <br /> REFRI ERATI N E IPMENT <br /> G 0 QU <br /> ooe000000�o�o�oloFoc�o�o�-.7-o <br /> N N TAININ MIXED WITH WATER T <br /> 0 S G 0 <br /> SUPPORT BEAM-SEE DETAIL 2. <br /> I <br /> CATION <br /> CONSISTENCY SUITABLE FOR APPLICATION � <br /> COOz. RDINATE LOCATION, <br /> 0 0 0 o SECTION AND A 30-MINUTE WORKING TIME." LENGTH,AND SPACING WITH <br /> O O O O O O O O O REFRIGERATION VENDOR. <br /> 1/4"BENT PL <br /> 6" EQ. EQ. 3" a <br /> I I <br /> o ----------------- rn <br /> 2i LU CD <br /> m o o o m Q 5'-5" 101-101, <br /> 10'-10" <br /> ui <br /> I I <br /> z0 0 <br /> 73- EQ. EQ. 6" Z�� Z <br /> pp pp 4 I � Y � <br /> PLAN LEND PL y0 o z 50 NO CURB.EXISTING <br /> 3"x3"x 1/4" <br /> p SIDEWALK MEETS H <br /> g0 9� <br /> 36"06"INTERNATIONAL GRADE AT PARKING LOT. REFRIGERATION EQUIPMENT U) Z O <br /> PAINT"NO PARKING"-12"H. HC SYMBOL,TYP. 2 STEEL SUPPORT � REFRIGERATION EQUIPMENT PLAN U) <br /> LETTERS,TYP.ALL ACCESS AISLES <br /> PROVIDE ADDITIONAL SIGN NOT LESS THAN 17 INCHES(432 MM)HIGH,CLEARLY _ - 0 cl <br /> STATING IN LETTERS WITH A MINIMUM HEIGHT OF 1"(25 MM)THE FOLLOWING: SCALE: 1"=V-0" SCALE: 1/4"=V-0" ui w <br /> "UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOTw <br /> DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR U Q <br /> PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT THE OWNER'S EXPENSE. <br /> 4 FRONT PARKING AREA TOWED VEHICLES MAY BE RECLAIMED AT: OR BY TELEPHONING: Q W <br /> ow <br /> Q J <br /> Z <br /> SCALE: 3/32" = V-0" EXISTING o Z:) <br /> Q PROPERTY LINE ~ 0 <br /> EXISTING < <br /> TRANSFORMER L!j O <br /> 256' O 0- <br /> - - T z c_n <br /> 0 Uj <br /> a >< <br /> M w <br /> oC/) <br /> U — <br /> Z W <br /> 16' Z <br /> z 0 <br /> 1 00 <br /> ADJACENT RD EXPRESS ENCLOSED BUILDING A-1.1 co o <br /> � w <br /> W <br /> ui <br /> ENCLOSED BUILDING 355612 SF EXISTING FENCE <br /> ENCLOSURE TO REMAIN 0 U_ <br /> 14'784 SF INCLUDING FUTURE EXPANSION 0 0 <br /> v <br /> 415345 SF = _I w <br /> NO WORK M l w ~ N <br /> Of <br /> I I J <br /> � � UU <br /> L" Q <br /> - ADJACENT FORMER <br /> 240' GARDEN CENTER <br /> EXISTING PARKING PALLET ENTRY EXIT 12,394 SF <br /> DOOR DOOR <br /> 202 SPACES (6 HC) <br /> RESTRI PE PARKING 7 — — — — ~EXISTING CANOPY <br /> STALLS AND FIRE oo � o 0 0 00 0 0000000 <br /> LANE MARKINGS <br /> o A-1.1 EXISTING FIRE 36"W.DETECTABLE PAVER EXISTING DOUBLE-SLIDING <br /> SURFACE-EXTEND 6"PAST ACCESS GATE TO REMAIN <br /> RISER <br /> EACH SIDE OF OPENING 4 REVISIONS <br /> DA 9 <br /> o <br /> Ln <br /> 0� LU <br /> O J <br /> EXISTING w <br /> LIGHT POLE w <br /> N M <br /> it 4t <br /> W H W <br /> Lu Lu Lu <br /> 0p Z Z Z <br /> 0 <br /> O <br /> 0 0 0 0 <br /> LU <br /> a <br /> w ON N N <br /> Q c <br /> 0 p O <br /> ` N7D <br /> HAMMER LANE M V U-) CO r-- co m O <br /> SITE PLAN & <br /> DETAILS <br /> FOR PERMIT DATE: 11/06/2020 <br /> JOB NO. 20263 <br /> SITE PLAN SHOWN FOR REFERENCE ONLY.NO WORK SITE PLANA� l <br /> ON BUILDING EXTERIOR/SITE EXCEPT AS NOTED. ■ <br /> 1 <br /> SCALE: 1"=30' <br /> SHEET N0. <br />
The URL can be used to link to this page
Your browser does not support the video tag.