Laserfiche WebLink
E <br /> DOOR NOTE: OCCUPANT LOAD W Z <br /> PANIC HARDWARE REQUIRED <br /> -OR- Z 1.1..1.1 v <br /> DOOR HARDWARE: ROOM OVERALL DEDUCTIONS REMAINING TOTAL <br /> _ _ _ _ _ _ _ _ SQ. FT. (CABS) SQ. FT. OCCUPANTS rn <br /> DOUBLE KEYED DEADBOLT MAY BE USED ON THE MAIN EXIT ONLY WHERE THE MAIN I— SIJ n 13 <br /> 21 <br /> EXIT CONSISTS OF A SINGLE DOOR OR A PAIR OF DOORS WHERE THERE IS A READILY I I I� I KITCHEN/PREP/SALES AREA 639 3 W <br /> VISIBLE, DURABLE SIGN ON OR ADJACENT TO THE DOOR STATING " THIS DOOR MUST 24 <br /> a <br /> REMAIN UNLOCKED DURING BUSINESS HOURS". i 1 U) 1 i DINNING 835 SEATS 0 <br /> TACTILE EXIT SIGN NOTE: I W I RESTROOM & HALL 345 - �? <br /> TACTILE EXIT SIGNS SHALL BE REQUIRED AT THE FOLLOWING LOCATIONS AND COMPLY (INCIDENTAL I (INCIDENTAL USE) Q .J <br /> WITH CBC SEC 1011.4 & 1 1 B 703 & 1 1 B 703.3 & 1113703.5 18" 1 CD 01 18" 1 <br /> W W W Q <br /> EACH GRADE-LEVEL EXTERIOR DOOR SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN 1 .- <br /> CWITH BC THE WORD "EXIT". BRAILLE SHALL BE CENTERED OR LEFT JUSTIFIED PER 2016 � X48" MIN. Z 1 SHUT-OFF <br /> CBC ° N <br /> I 1 C\I / I PRIVATE � ° I I I 0 � � <br /> PROVIDE TACTILE EXIT SIGNS AT ALL EXIT DOORS. MOUNT AT 5'-0" A.F.F. TO HIGHEST I 1 0 / I RES ��'RROOM x i TOTAL S.F. 1 ,819 — T E <br /> \ �' <br /> BRAILLE LINE. - w' �E DRAIN I I II TOTAL OCCUPANTS 27 Ln 0 j <br /> 1 12 1 ° .04. <br /> 1 — (E) DRAIN ® 1 _ E <br /> �I .. <br /> 1 1 FIRE I II II FIRE EXTINGUISHER REQUIREMENTS LL <br /> 1 U° x I 12440 I <br /> 1 R ® 1 I I PROVIDE A MIN OF 2 FIRE EXTINGUISHER WITH A 2A: 10-B:C "��� 0 <br /> 1 <br /> 1 K I II I <br /> MIN. RATING. LOCATION OF FIRE EXTINGUISHERS TO BE \--I �/ a w <br /> R I I I I I APPROVED BY FIRE MARSHAL <br /> 1 0 L - - F = EIRE EXTINGUISHER <br /> 1 <br /> 1 ® \ I � I Z BUILDING DEPARTMENT <br /> - - � - — NEW SUB \ J I I i FIRE EXTINGUISHER MOUNTING HEIGHT NAME: <br /> ll <br /> 48" 1IN I WORK ZI KITCHEN � CITY OF STOCKTON <br /> 1 0 i I SPACE �I 20 q IIS ADDRESS: <br /> L - - - 1- - - �_--IN (n EGRESS - - - - - - - - - - - - - - _ <br /> 425 N. ELDORADO ST. <br /> I 1 � <br /> L _ _ 2 18 c/)1 3o II ROOM ROOM CAPACITY STOCKTON, CA 95202 <br /> 1 - - - - - J U) II NUMBERS & EMERGENCY PHONE: <br /> �� 108" x 48" �; I/ EXIT SIGNS 209-937-8561 <br /> W 1 W 1 BUILDING OWNER <br /> p I X NAME: <br /> 10l <br /> Q BECK PROPERTIES <br /> W 1 1 INSTALL FIRE W <br /> >Z ADDRESS: <br /> 1 00 EXTINGUISHERS IN > 3114 W. HAMMER LN. <br /> ARCH 1 0 o ARCH ACCORDANCE WITH 0 STOCKTON, CA 95209 <br /> 1 0 1 THE 2016 C.F.C. <br /> 1 36" HEIGHT 1 SEC 906 PHONE: <br /> 48" MIN. (209) 957-0331 <br /> I 1 � / � I <br /> EMPLOYEES 0 EGRESS 1 <br /> FINISHED FLOOR TENANT <br /> NAME: <br /> L — — 112 18" — J z YUMMY DONUTS <br /> 1 8 FT. PASTRY DISPLAY 8 Fr. PASTRY DISPLAY POS FIRE EXTINGUISHER MOUNTING HEIGHT z ADDRESS: <br /> 1 33 1/2" HEIGHT 36 HEIGHT Z <br /> FIRE DEPT. NOTES: LU 3221 W. HAMMER LN. <br /> 1-- STOCKTON, CA 95209 <br /> 1. FIRE DEPT. FINAL INSPECTION REQUIRED. SCHEDULE INSPECTIONS 2 DAYS IN <br /> FIRE I ADVANCE. PHONE: <br /> 1 \ 209 <br /> C 2. LOCATIONS AND CLASSIFICATIONS OF FIRE EXTINGUISHERS SHALL BE IN ( ) 636-8909 <br /> c r 1 EGRESS ACCORDANCE WITH THE UNIFORM FIRE CODE STANDARD 10-1 AND PLACEMENT IS <br /> - - - - - , / SUBJECT TO THE APPROVAL OF THE FIRE INSPECTION. VERIFY QUANTITY AND EXACT LIC. j <br /> E 1 1 L LOCATION FROM FIRE DEPARTMENT PRIOR TO ORDERING. <br /> R I I 3. STORAGE, DISPENSING OR USE OF ANY FLAMMABLE AND COMBUSTIBLE LIQUIDS, O NAME: <br /> FLAMMABLE AND COMPRESSED GASES, AND OTHER HAZARDOUS MATERIALS SHALL F.- T.B.D. <br /> COMPLY WITH UNIFORM FIRE CODE REGULATIONS. THE STORAGE AND USE OF () <br /> HAZARDOUS MATERIALS SHALL BE APPROVED BY THE FIRE AUTHORITY PRIOR TO ANY Q <br /> > I O O MATERIALS BEING STORED OR USED ON SITE. A SEPARATE PLAN SUBMITTAL IS � ADDRESS: <br /> REQUIRED PRIOR TO THE STORAGE AND USE OF HAZARDOUS MATERIALS. <br /> 4. BUILDING NOT APPROVED FOR HIGH-PILED STOCK (MATERIALS IN CLOSELY z <br /> PACKED PILES OR ON PALLETS, OR IN RACKS WHERE THE TOP OF THE STORAGE O <br /> EXCEEDS 12 FEET IN HEIGHT, AND 6 FEET FOR GROUP A PLASTICS AND CERTAIN () PHONE: <br /> OTHER HIGH-HAZARD COMMODITIES). HIGH-PILED STOCK SHALL BE APPROVED BY THE <br /> O O ! O O 1 O O FIRE AUTHORITY PRIOR TO MATERIALS BEING STORED ON SITE. A SEPARATE PLAN <br /> SUBMITTAL IS REQUIRED FOR HIGH-PILED STORAGE IN ACCORDANCE WITH THE UNIFORM <br /> 1 1 FIRE CODE, ARTICLE 81. QROFES$/�N� <br /> 1 DINNING AREA 1 5. FIRE SPRINKLER SYSTEM(S) PER UBC STD. 38-1 AND NFPA STD. 13 SHALL BE ��� �tW A. <br /> 00 00 <br /> 1 24 SEATS 1 PROVIDED TO PROTECT ENTIRE BUILDING INCLUDING PROJECTIONS OVER 4 FEET AND <br /> z 1 1 z SPRAY BOOTH. W C �Q y <br /> nel O O O O 6. FIRE SPRINKLERS SYSTEM(S) AND ALL CONTROL VALVES, INCLUDING EXTERIOR W No. C74034T T SHALL BE SUPERVISED BY A U.L. LISTED CENTRAL ALARM STATION OR PER UFC, ART. zW 1 0 74.U)1 u)1 7. PLANS OF NEW OR MODIFICATIONS TO EXISTING FIRE PROTECTION, DETECTION, z OFF1 1 ALARM OR MONITORING SYSTEMWS) SHALL BE APPROVED BY THE FIRE AUTHORITY TO 9TW W 0�1 \ O 0�1 O O INSTALLATION. A SEPARATE PLAN FOR SUBMITTAL AND APPROVAL IS REQUIRED PRIOR <br /> TO THE COMMENCEMENT OF ANY WORK. PHONE: <br /> W W 1 1 <br /> 8. ACCESS GATES SHALL BE IN COMPLIANCE WITH UNIFORM FIRE CODE, SECTION 209-263-1382 <br /> 902 AND FIRE DEPARTMENT GUIDELINES. A SEPARATE PLAN SUBMITTAL AND APPROVAL <br /> �.— �, — — �,I — — IS REQUIRED. CONSTRUCTION SITE <br /> z 60 MIN. 60 MIN. z <br /> I 1 I I 1 I 9. A LETTER OF INTENDED USE MAY BE REQUIRED BY THE FIRE INSPECTOR. Z SITE ADDRESS: <br /> 1 _ I Q <br /> 100 I I 1 00 I 10. AN AUTOMATIC EXTINGUISHING SYSTEM HAS BEEN INTIGRATED INTO THE 3221 W. HAMMER LN. STE.A&B <br /> 1 I TRASH (N) +48 TRASH 1 I COMMERCIAL HOOD TO BE PROVIDED BY "CAPTIVE AIRE." IN ACCORDANCE WITH UFC STOCKTON, CA 95209 <br /> "t2 <br /> 18 ARTICLE 10, NFPA 17A AND 96. SEE MECHANICAL DRAWINGS. <br /> - - - -r - w <br /> SITE APN: <br /> LL 82-220-03 <br /> ILL i <br /> \\ I I m o \ I U) DRAWING INFORMATION <br /> I � I 0 I <br /> W REVISION DATE <br /> z NIW ,09 I I z NIW ,09 I J 4-25-19 <br /> LLI FILE NAME: <br /> cl� 19-0311 —YUMMY—DONUTS <br /> LL. DRAWING SCALE: <br /> FIRE LIFE SAFETY <br /> 1/4" = 1 ' <br /> SCALE: 1/4" = 1 ' A Q0 <br />