E <br /> 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE W Z <br /> .01 <br /> Z `4 <br /> N <br /> E3 0 <br /> NONRESIDENTIAL MANDATORY MEASURES ' SHEET 2 _ - rl 2�nca;tt! <br /> Ln .21J <br /> INSPECTOR INSPECTOR INSPECTOR INSPECTORr <br /> SIGNOFF 5.410.2.1 Owner's or Owner Representative's Project Requirements(OPR).[N] The expectations and SIGNOFF SECTION 5.504 POLLUTANT CONTROL SIGNOFF TABLE 5.504.4.3 - VOC CONTENT LIMITS FOR ARCHITECTURAL SIGNOFF 5.504.4.6 Resilient flooring systems. For 80 percent of floor area receiving resilient flooring, installed a - <br /> requirements of the building appropriate to its phase shall be documented before the design phase of the project 5.504.1.3 Temporary ventilation. The permanent HVAC system shall only be used during construction if C OATI N GS2,3 resilient flooring shall meet at least one of the following: E <br /> begins.This documentation shall include the following: MANDATORY necessary to condition the building or areas of addition or alteration within the required temperature range for 1. Certified under the Resilient Floor Covering Institute(RFCI)FloorScore program; <br /> 2 4) <br /> 1. Environmental and sustainability goals. material and equipment installation. If the HVAC system is used during construction, use return air filters with a GRAMS OF VOC PER LITER OF COATING, LESS WATER & LESS EXEMPT COMPOUNDS 2. Compliant with the VOC-emission limits and testing requirements specified in the California .. <br /> 2. Energy efficiency goals[refer to 2016 California Energy Code,Section 120.8(b)]. Minimum Efficiency Reporting Value(MERV)of 8,based on ASHRAE 52.2-1999,or an average efficiency of 30% COATING CATEGORY CURRENT VOC LIMIT Department of Public Health's 2010 Standard Method for the Testing and Evaluation Chambers,Version N <br /> 3. Indoor environmental quality requirements. based on ASHRAE 52.1-1992 Replace all filters immediately prior to occupancy,or,if the building is occupied 1.1, February 2010; 14 J <br /> 4. Project program,including facility functions and hours of operation,and need for after hours operation. during alteration,at the conclusion of construction. FLAT COATINGS 50 3. Compliant with the California Collaborative for High Performance Schools(CA-CHPS)Criteria <br /> 5. Equipment and systems expectations. Interpretation for EQ 2.2 dated July 2012 and listed in the CHPS High Performance Product Database;or W <br /> 6. Building occupant and operation and maintenance(O&M)personnel expectations. 5.504.3 Covering of duct openings and protection of mechanical equipment during construction. At the time of NONFLAT COATINGS 100 4. Compliant with CDPH criteria as certified under the Greenguard Children's&Schools Program. <br /> MANDATORY rough installation,or during storage on the construction site and until final startup of the heating,cooling and MANDATORY .. <br /> 5.410.2.2 Basis of Design(BOD).[A] A written explanation of how the design of the building systems meets the ventilating equipment,all duct and other related air distribution component openings shall be covered with tape, NONFLAT HIGH GLOSS COATINGS 150 5.504.4.6.1 Verification of compliance. Documentation shall be provided verifying that resilient flooring - IS c <br /> OPR shall be completed at the design phase of the building project.The Basis of Design document shall cover the plastic,sheet metal or other methods acceptable to the enforcing agency to reduce the amount of dust,water and materials meet the pollutant emission limits. rn <br /> SPECIALTY COATINGS 1..1 U) N <br /> E9 <br /> following systems: debris which may collect in the system. <br /> 1. Heating,ventilation,air conditioning(HVAC)systems and controls[refer to 2016 California Energy Code, ALUMINUM ROOF COATINGS 400 5.504.5.3 Filters. In mechanically ventilated buildings,provide regularly occupied areas of the building with air - T E <br /> Section 120.8(c)]. 5.504.4 Finish material pollutant control. Finish materials shall comply with Sections 5.504.4.1 through 5.504.4.4. filtration media for outside and return air that provides at least a Minimum Efficiency Reporting Value(MERV)of 8. O 0 <br /> 2. Indoor lighting system and controls refer to 2016 California Ener Code,Section 120.8 c MANDATORY BASEMENT SPECIALTY COATINGS 400 MANDATORY MERV 8 filters shall be installed prior to occupancy,and recommendations for maintenance with filters of the � Q O a <br /> 9 9 Y [ 9Y ( )l� p <br /> 3. Water heating system[refer to 2016 California Energy Code,Section 120.8(c)]. 5.504.4.1 Adhesives,sealants and caulks. Adhesives,sealants,and caulks used on the project shall meet same value shall be included in the operation and maintenance manual. 0 <br /> 4. Renewable energy systems. the requirements of the following standards: BITUMINOUS ROOF COATINGS 50 Exceptions: O <br /> 5. Landscape irrigation systems. 1. Adhesives,adhesive bonding primers adhesive primers,sealants,sealant primers and caulks shall 1. An ASHRAE 10%to 15%efficiency filter shall be permitted for an HVAC unit meeting the 2016 N <br /> BITUMINOUS ROOF PRIMERS 350 E <br /> 6. Water reuse systems. comply with local or regional air pollution control or air quality management district rules where California Energy Code having 60,000 Btu/h or less capacity per fan coil, if the energy use of the air <br /> applicable,or SCAQMD Rule 1168 VOC limits,as shown in Tables 5.504.4.1 and 5.504.4.2.Such BOND BREAKERS 350 delivery system is 0.4 W/cfm or less at design air flow. <br /> 5.410.2.3 Commissioning plan.[N] Prior to permit issuance a commissioning plan shall be completed to products also shall comply with the Rule 1168 prohibition on the use of certain toxic compounds 2. Existing mechanical equipment. LL <br /> document how the project will be commissioned.The commissioning plan shall include the following: (chloroform,ethylene dichloride,methylene chloride,perchloroethylene and trichloroethylene),except for CONCRETE CURING COMPOUNDS 350 . ._ <br /> 1. General project information. aerosol products as specified in subsection 2,below. 5.504.7 ENVIRONMENTAL TOBACCO SMOKE(ETS)CONTROL. Where outdoor areas are provided for smoking, <br /> 2. Commissioning goals. CONCRETE/MASONRY SEALERS 100 prohibit smoking within 25 feet of building entries,outdoor air intakes and operable windows and within the <br /> 3. Systems to be commissioned. Plans to test systems and components shall include: 2. Aerosol adhesives,and smaller unit sizes of adhesives,and sealant or caulking compounds(in building as already prohibited by other laws or regulations;or as enforced by ordinances,regulations or policies of t <br /> DRIVEWAY SEALERS 50 <br /> a Anexplanation f the original design intent. units of product,less packaging,which do not weigh more than one pound and do not consist of more an city,county,city and county,California Community College,campus of the California State University,or <br /> d � <br /> b. Equipment and systems to be tested, including the extent of tests. than 16 fluid ounces)shall comply with statewide VOC standards and other requirements,including DRY FOG COATINGS 150 campus of the University of California,whichever are more stringent.When ordinances, regulations or policies are W <br /> c. Functions to be tested. prohibitions on use of certain toxic compounds,of California Code of Regulations,Title 17,commencing not in place,post signage to inform building occupants of the prohibitions. <br /> d. Conditions under which the test shall be performed. with Section 94507. FAUX FINISHING COATINGS 350 <br /> e. Measurable criteria for acceptable performance. SECTION 5.505 INDOOR MOISTURE CONTROL <br /> 4. Commissioning team information. FIRE RESISTIVE COATINGS 350 5.505.1 INDOOR MOISTURE CONTROL. Buildings shall meet or exceed the provisions of California Building Code, <br /> 5. Commissioning process activities,schedules and responsibilities.Plans for the completion of TABLE 5.504.4.1 - ADHESIVE VOC LIMITI,2 CCR,Title 24,Part 2,Sections 1203(Ventilation)and Chapter 14(Exterior Walls). For additional measures not BUILDING DEPARTMENT <br /> commissioning shall be included. FLOOR COATINGS 100 applicable to low-rise residential occupancies,see Section 5.407.2 of this code. <br /> Z <br /> Less Water and Less Exempt Compounds in Grams per Liter FORM-RELEASE COMPOUNDS 250 O NAME: <br /> 5.410.2.4 Functional performance testing.[A] Functional performance tests shall demonstrate the correct ARCHITECTURAL APPLICATIONS CURRENT VOC LIMIT SECTION 5.506 INDOOR AIR QUALITY <br /> installation and operation of each component,system and system-to-system interface in accordance with the GRAPHIC ARTS COATINGS (SIGN PAINTS) 500 5.506.1 OUTSIDE AIR DELIVERY. For mechanically or naturally ventilated spaces in buildings, meet the minimum � CITY OF STOCKTON <br /> approved plans and specifications. Functional performance testing reports shall contain information addressing INDOOR CARPET ADHESIVES 50 requirements of Section 121 (Requirements For Ventilation)of the 2010 California Energy Code,or the applicable U <br /> each of the buildingcomponents tested,the testingmethods utilized,and include an readings and adjustments HIGH-TEMPERATURE COATINGS 420 <br /> p y g i CARPET PAD ADHESIVES 50 local code,whichever is more stringent,and Division 1, Chapter 4 of CCR, Title 8. 0 ADDRESS: <br /> made. INDUSTRIAL MAINTENANCE COATINGS 250 <br /> 5.410.2.5 Documentation and training.[N] A Systems Manual and Systems Operations Training are required, OUTDOOR CARPET ADHESIVES 150 5.506.2 CARBON DIOXIDE(CO2)MONITORING. For buildings or additions equipped with demand control W 425 N. ELDORADO ST. <br /> includingOccupational Safety and Health Act OSHA requirements in California Code of Regulations(CCR),Title LOW SOLIDS COATINGSI 120 ventilation,CO2 sensors and ventilation controls shall be specified and installed in accordance with the <br /> p Y . ) q g ( ) WOOD FLOORING ADHESIVES 100 requirements of the 2016 California Energy Code,Section 120(c)(4). STOCKTON, CA 95202 <br /> 8,Section 5142,and other related regulations. MAGNESITE CEMENT COATINGS 450 � <br /> RUBBER FLOOR ADHESIVES 60 MASTIC TEXTURE COATINGS 100 SECTION 5.507 ENVIRONMENTAL COMFORT PHONE: <br /> 5.410.2.5.1 Systems manual.[N] Documentation of the operational aspects of the building shall be <br /> completed within the systems manual and delivered to the building owner or representative.The systems manual SUBFLOOR ADHESIVES 50 5.507.4 ACOUSTICAL CONTROL. Employ building assemblies and components with Sound Transmission Class 209-937-8561 <br /> shall include the following: METALLIC PIGMENTED COATINGS 500 (STC)values determined in accordance with ASTM E 90 and ASTM E 413,or Outdoor-Indoor Sound <br /> CERAMIC TILE ADHESIVES 65 Transmission Class(OITC)determined in accordance with ASTM E 1332,using either the prescriptive or <br /> 1. Site information, including facility description, history and current requirements. MULTICOLOR COATINGS 250 <br /> 2. Site contact information. VCT & ASPHALT TILE ADHESIVES 50 performance method in Section 5.507.4.1 or 5.507.4.2. BUILDING OWNER 3. Basic operations and maintenance, including general site operating procedures, basic PRETREATMENT WASH PRIMERS 420DRYWALL & PANEL ADHESIVES 50 Exception: Buildings with few or no occupants or where occupants are not likely to be affected by exterior noise, <br /> troubleshooting, recommended maintenance requirements,site events log. PRIMERS, SEALERS, & UNDERCOATERS 100 as determined by the enforcement authority,such as factories,stadiums,storage,enclosed parking structures and NAME: <br /> 4. Major systems. COVE BASE ADHESIVES 50 utility buildings. BECK PROPERTIES <br /> 5. Site equipment inventory and maintenance notes. REACTIVE PENETRATING SEALERS 350 w <br /> 6. A copy of verifications required by the enforcing agency or this code. MULTIPURPOSE CONSTRUCTION ADHESIVES 70 RECYCLED COATINGS 250 Exception:[DSA-SS] For public schools and community colleges,the requirements of this section and all <br /> 7. Other resources and documentation,if applicable. STRUCTURAL GLAZING ADHESIVES 100 ROOF COATINGS 50 subsections apply only to new construction. Z ADDRESS: <br /> 3114 W. HAMMER LN. <br /> 5.410.2.5.2 Systems operations training.[N]A program for training of the appropriate maintenance staff for SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 5.507.4.1 Exterior noise transmission,prescriptive method. Wall and roof-ceiling assemblies exposed to the O <br /> each equipment type and/or system shall be developed and documented in the commissioning report and shall RUST PREVENTATIVE COATINGS 250 noise source making up the building or addition envelope or altered envelope shall meet a composite STC rating STOCKTON, CA 95209 <br /> include the following: OTHER ADHESIVES NOT SPECIFICALLY 50 of at least 50 or a composite OITC rating of no less than 40,with exterior windows of a minimum STC of 40 or <br /> LISTED SHELLACS: OITC of 30 in the following locations: <br /> 1. System/equipment overview(what it is,what it does and with what other systems and/or equipment PHONE: <br /> it interfaces). SPECIALTY APPLICATIONS CLEAR 730 1. Within the 65 CNEL noise contour of an airport. <br /> 2. Review and demonstration of servicing/preventive maintenance. L (209) 957-0331 <br /> 3. Review of the information in the Systems Manual. PVC WELDING 510 OPAQUE 550 Exceptions: <br /> 1. Ldn or CNEL for military airports shall be determined by the facility Air Installation Compatible <br /> 4. Review of the record drawings on the system/equipment. CPVC WELDING 490 SPECIALTY PRIMERS, SEALERS & UNDERCOATERS 100 Land Use Zone(AICUZ)plan. TENANT <br /> 5.410.2.6 Commissioningort. Are ort of commissioningprocess activities undertaken through the design, ABS WELDING 325 2. Lan or CNEL for other airports and heliports for which a land use plan has not been developed <br /> report. p g g STAINS 250 shall be determined by the local general plan noise element. NAME: <br /> construction phases of the building project shall be completed and provided to the owner or representative. PLASTIC CEMENT WELDING 250 <br /> STONE CONSOLIDANTS 450 2. Within the 65 CNEL or Ldn noise contour of a freeway or expressway,railroad,industrial source or YUMMY DONUTS <br /> Note: Guidance on implementation and enforcement of commissioning requirements, including sample ADHESIVE PRIMER FOR PLASTIC 550 fixed-guideway source as determined by the Noise Element of the General Plan. Z <br /> compliance forms and templates, may be found in Appendix A6, Division A6.1,of this code. SWIMMING POOL COATINGS 340 Q <br /> CONTACT ADHESIVE 80 5.507.4.2 Performance Method. For buildings located as defined in Section 5.507.4.1 or 5.507.4.1.1,wall and ADDRESS: <br /> TRAFFIC MARKING COATINGS 100 Z <br /> 5.410.4 TESTING AND ADJUSTING. Testing and adjusting of systems shall be required for buildings less than roof-ceiling assemblies exposed to the noise source making up the building or addition envelope or altered <br /> SPECIAL PURPOSE CONTACT ADHESIVE 250 envelope shall be constructed to provide an interior noise environment attributable to exterior sources that does W 3221 W. HAMMER LN. <br /> 10,000 square feet or new systems to serve an addition or alteration subject to Section 303.1. TUB & TILE REFINISH COATINGS 420 not exceed an hour) equivalent noise level(Leq-1 Hr of 50 BBA in occupied areas Burin an hour of operation.STRUCTURAL WOOD MEMBER ADHESIVE 140 Y q ( q- ) p g Y p STOCKTON, CA 95209 <br /> 5.410.4.2 Systems. Develop a written plan of procedures for testing and adjusting systems.Systems to be WATERPROOFING MEMBRANES 250 <br /> TOP & TRIM ADHESIVE 250 5.507.4.2.1 Site Features. Exterior features such as sound walls or earth berms may be utilized as <br /> included for testing and adjusting shall include at a minimum,as applicable to the project: WOOD COATINGS 275 appropriate to the building,addition or alteration project to mitigate sound migration to the interior. PHONE: <br /> 1. HVAC systems and controls. SUBSTRATE SPECIFIC APPLICATIONS <br /> 2. Indoor and outdoor lighting and controls. WOOD PRESERVATIVES 350 5.507.4.2.2 Documentation of Compliance. An acoustical analysis documenting complying interior sound Ll (209) 636-8909 <br /> 3. Water heating systems. METAL TO METAL 30 levels shall be prepared by personnel approved by the architect or engineer of record. <br /> PLASTIC FOAMS 50 <br /> 4. Renewable energy systems. ZINC-RICH PRIMERS 340 <br /> 5. Landscape irrigation systems. 1. GRAMS OF VOC PER LITER OF COATING, INCLUDING WATER & EXEMPT COMPOUNDS 5.507.4.3 Interior sound. Wall and floor-ceiling assemblies separating tenant spaces and tenant spaces and LIC. <br /> 6. Water reuse systems. POROUS MATERIAL (EXCEPT WOOD) 50 public places shall have an STC of at least 40. <br /> COLUMNS IN THE TABLE. O NAME: <br /> 2. THE SPECIFIED LIMITS REMAIN IN EFFECT UNLESS REVISED LIMITS ARE LISTED IN SUBSEQUENT Note: Examples of assemblies and their various STC ratings may be found at the California Office of Noise <br /> 5.410.4.3 Procedures. Perform testing and adjusting procedures in accordance with manufacturer's WOOD 30 Control: www.tooIbase.org/PDF/CaseStudies/stc-icc-ratings.pdf. ~ T.B.D. <br /> specifications and applicable standards on each system. 3. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR U <br /> FIBERGLASS 80 RESOURCES BOARD, ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE, FEB. 1, 2008. <br /> MORE INFORMATION IS AVAILABLE FROM THE AIR RESOURCES BOARD. CHAPTER 7 Q ADDRESS:shall 5.410.4.3.1 HVAC balancing. In addition to testing and adjusting, before a new space-conditioning system MANDATORY 5.504.4.3.2 Verification.Verification of compliance with this section all be provided at the request of <br /> serving a building or space is operated for normal use,the system shall be balanced in accordance with the 1. IF AN ADHESIVE IS USED TO BOND DISSIMILAR SUBSTRATES the enforcing agency.Documentation may include, but is not limited to,sh the following: INSTALLER & SPECIAL INSPECTOR QUALIFICATIONS <br /> procedures defined the Testing Adjusting and Balancing Bureau National Standards;the National TOGETHER, THE ADHESIVE WITH THE HIGHEST VOC CONTENT SHALL 1. Manufacturer's product specification 702 QUALIFICATIONS Z <br /> Environmental Balancing <br /> ng Bureau Procedural Standards;Associated Air Balance Council National Standards or as BE ALLOWED. 2. Field verification of on-site product containers O <br /> approved by the enforcing agency. 702.1 INSTALLER TRAINING. HVAC system installers shall be trained and certified in the proper <br /> EXISTING 2. FOR ADDITIONAL INFORMATION REGARDING METHODS TO 5.504.4.4 Carpet Systems.All carpet installed in the building interior shall meet at least one of the testing and installation of HVAC systems including ducts and equipment by a nationally or regionally recognized U PHONE: <br /> 5.410.4.4 Reporting. After completion of testing,adjusting and balancing,provide a final report of testing MEASURE THE VOC CONTENT SPECIFIED IN THIS TABLE, SEE SOUTH product requirements: training or certification program. Uncertified persons may perform HVAC installations when under the <br /> N/A signed by the individual responsible for performing these services. COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168, 1. Carpet and Rug Institute's Green Label Plus Program. direct supervision and responsibility of a person trained and certified to install HVAC systems or <br /> www.arb.ca.gov/DRDB/SC/CURHTML/Rl 168.PDF N/A 2. Compliant with the VOC-emission limits and testing requirements specified in the California contractor licensed to install HVAC systems. Examples of acceptable HVAC training and certification <br /> 5.410.4.5 Operation and maintenance(O&M)manual. Provide the building owner or representative with - Department of Public Health Standard Method for the Testing and Evaluation of Volatile Organic programs include but are not limited to the following: FESS <br /> detailed operating and maintenance instructions and copies of guaranties/warranties for each system.0&M TABLE 5.504.4.2 SEALANT VOC LIMIT Chemical Emissions from Indoor Sources Using Environmental Chambers,Version 1.1, February 2010 1. State certified apprenticeship programs. QRS //ON� <br /> instructions shall be consistent with OSHA requirements in CCR,Title 8,Section 5142,and other related (also known as CDPH Standard Method V1.1 or Specification 01350). 2. Public utility training programs. �� w A <br /> Less Water and Less Exempt Compounds in Grams per Liter 3. NSF/ANSI 140 at the Gold level or higher; 3. Training programs sponsored b trade,labor or statewide energy consulting or verification <br /> regulations. g 9 P g p Y gY g � �� <br /> 4. Scientific Certifications Systems Sustainable Choice; or organizations. ,` <br /> c.� <br /> SEALANTS CURRENT VOC LIMIT p y <br /> 5. Compliant with the California Collaborative for High Performance Schools(CA-CHPS)Criteria 4. Programs sponsored by manufacturing organizations. LU � <br /> by5. the enforcing <br /> Inspections and reports. Include a copy of all inspection verifications and reports required ARCHITECTURAL 250 Interpretation for EQ 2.2 dated July 2012 and listed in the CHPS High Performance Product Database. 5. Other programs acceptable to the enforcing agency. L]i <br /> by the enforcing agency. No. C74034 z' <br /> DIVISION 5.5 ENVIRONMENTAL QUALITY MARINE DECK 760 5.504.4.4.1 Carpet cushion.All carpet cushion installed in the building interior shall meet the 702.2 SPECIAL INSPECTION [HCD]. When required by the enforcing agency,the owner or Z EXP. <br /> requirements of the Carpet and Rug Institute Green Label program. the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide <br /> NONMEMBRANE ROOF 300 UI s \Q <br /> SECTION 5.501 GENERAL inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall lq CIV1L <br /> 5.501.1 SCOPE. The provisions of this chapter shall outline means of reducing the quantity of air contaminants that 5.504.4.4.2 Carpet adhesive.All carpet adhesive shall meet the requirements of Table 5.504.4.1. demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection Z Til 0 <br /> are odorous, irritating,and/or harmful to the comfort and well-being of a building's installers,occupants and ROADWAY 250 or task to be performed. In addition to other certifications or qualifications acceptable to the enforcing OF CA��F <br /> 9 9' P P q P 9 LLI <br /> neighbors. SINGLE-PLY ROOF MEMBRANE 450 5.504.4.5 Composite wood products. Hardwood plywood,particleboard and medium density fiberboard agency,the following certifications or education may be considered by the enforcing agency when <br /> composite wood products used on the interior or exterior of the buildings shall meet the requirements for evaluating the qualifications of a special inspector: PHONE: <br /> SECTION 5.502 DEFINITIONS OTHER 420 formaldehyde as specified in ARB's Air Toxics Control Measure for Composite Wood(17 CCR 93120 et seq.). <br /> 5.502.1 DEFINITIONS. The following terms are defined in Chapter 2 (and are included here for reference) Those materials not exempted under the ATCM must meet the specified emission limits,as shown in Table 1. Certification by a national or regional green building program or standard publisher. Ll 209-263-1382 <br /> SEALANT PRIMERS 5.504.4.5. 2. Certification by a statewide energy consulting or verification organization,such as HERS raters, <br /> COMMUNITY NOISE EQUIVALENT LEVEL(CNEL). A metric similar to the day-night average sound level(Ldn), ARCHITECTURAL building performance contractors,and home energy auditors. <br /> except that a 5 decibel adjustment is added to the equivalent continuous sound exposure level for evening hours(7pm 5.504.4.5.3 Documentation. Verification of compliance with this section shall be provided as requested 3. Successful completion of a third party apprentice training program in the appropriate trade. (n CONSTRUCTION SITE <br /> to 10pm)in addition to the 10 dB nighttime adjustment used in the Ldn. NONPOROUS 250 MANDATORY by the enforcing agency. Documentation shall include at least one of the following: 4. Other programs acceptable to the enforcing agency. 0 <br /> 1. Product certifications and specifications. ()� SITE ADDRESS: <br /> COMPOSITE WOOD PRODUCTS. Composite wood products include hardwood plywood, particleboard and medium POROUS 775 2. Chain of custody certifications. Notes: <br /> density fiberboard."Composite wood products"does not include hardboard,structural plywood,structural panels, 500 3. Product labeled and invoiced as meeting the Composite Wood Products regulation(see 1. Special inspectors shall be independent entities with no financial interest in the materials or the Q 3221 W. HAMMER LN. STE.A&B <br /> MODIFIED BITUMINOUS D <br /> structural composite lumber,oriented strand board,glued laminated timber,timber,prefabricated wood I-joists or CCR,Title 17, Section 93120,et seq.). project they are inspecting for compliance with this code. <br /> finger-jointed lumber,all as specified in California Code of Regulations(CCR),Title 17,Section 93120.1(a). MARINE DECK 760 4. Exterior grade products marked as meeting the PS-1 or PS-2 standards of the Engineered 2. HERS raters are special inspectors certified by the California Energy Commission(CEC)to rate Z STOCKTON, CA 95209 <br /> Wood Association,the Australian AS/NZS 2269 or European 636 3S standards. homes in California according to the Home Energy Rating System(HERS). Q <br /> Note: See CCR,Title 17,Section 93120.1. OTHER 7505. Other methods acceptable to the enforcing agency. SITE APN: <br /> [BSC] When required by the enforcing agency,the owner or the responsible entity acting as the owner's U) <br /> MERV. Filter minimum efficiency reporting value,based on ASHRAE 52.2-1999. NOTE: FOR ADDITIONAL INFORMATION REGARDING METHODS TO TABLE 5.504.4.5 - FORMALDEHYDE LI M ITS1 agent shall employ one or more special inspectors to provide inspection or other duties necessary toUr 82-220-03 <br /> MEASURE THE VOC CONTENT SPECIFIED IN THESE TABLES, SEE substantiate compliance with this code. Special inspectors shall demonstrate competence to the <br /> REACTIVE ORGANIC COMPOUND(ROC). Any compound that has the potential,once emitted,to contribute to SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168. MAXIMUM FORMALDEHYDE EMISSIONS IN PARTS PER MILLION satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In Z DRAWING INFORMATION <br /> ozone formation in the troposphere. addition,the special inspector shall have a certification from a recognized state, national or international 0 <br /> PRODUCT CURRENT LIMIT association,as determined b the local agency. The area of certification shall be close) related to the <br /> 5.504.4.3 Paints and coatings. Architectural paints and coatings shall comply with VOC limits in Table 1 of Y 9 Y• Y J REVISION DATE <br /> VOC. A volatile organic compound broadly defined as a chemical compound based on carbon chains or rings with the ARB Architectural Coatings Suggested Control Measure,as shown in Table 5.504.4.3,unless more HARDWOOD PLYWOOD VENEER CORE 0.05 primary job function,as determined by the local agency. <br /> vapor pressures greater than 0.1 millimeters of mercury at room temperature.These compounds typically contain stringent local limits apply.The VOC content limit for coatings that do not meet the definitions for the specialty 4-25-19 <br /> hydrogen and may contain oxygen,nitrogen and other elements.See CCR Title 17,Section 94508(a). coatings categories listed in Table 5.504.4.3 shall be determined by classifying the coating as a Flat,Nonflat HARDWOOD PLYWOOD COMPOSITE CORE 0.05 Note: Special inspectors shall be independent entities with no financial interest in the materials or C0 <br /> Note: Where specific regulations are cited from different agencies such as SCAQMD,ARB,etc.,the VOC or Nonflat-High Gloss coating, based on its gloss,as defined in Subsections 4.21,4.36 and 4.37 of the 2007 the project they are inspecting for compliance with this code. Z FILE NAME: <br /> definition included in that specific regulation is the one that prevails for the specific measure in question. California Air Resources Board Suggested Control Measure,and the corresponding Flat, Nonflat or PARTICLE BOARD 0.09 LLI 19-0,311 -YUMMY-DONUTS <br /> SECTION 5.503 FIREPLACES Nonflat-High Gloss VOC limit in Table 5.504.4.3 shall apply. MEDIUM DENSITY FIBERBOARD 0.11 703 VERIFICATIONS W <br /> 5.503.1 GENERAL. Install only a direct-vent sealed-combustion gas or sealed wood-burning fireplace,or a sealed 703.1 DOCUMENTATION. Documentation used to show compliance with this code shall include <br /> 5.504.4.3.1 Aerosol Paints and coatings. Aerosol paints and coatings shall meet the PWMIR Limits for THIN MEDIUM DENSITY FIBERBOARD2 0.13 DRAWING SCALE: <br /> woodstove or pellet stove,and refer to residential requirements in the California Energy Code,Title 24, Part 6, but is not limited to,construction documents, plans,specifications, builder or installer certification, (� <br /> N/A ROC in Section 94522(a)(3)and other requirements, including prohibitions on use of certain toxic compounds <br /> Subchapter 7,Section 150.Woodstoves,pellet stoves and fireplaces shall comply with applicable local 1. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR inspection reports,or other methods acceptable to the enforcing agency which demonstrate substantial N/A <br /> ordinances. and ozone depleting substances,in Sections 94522(c)(2)and(d)(2)of California Code of Regulations,Title RESOURCES BOARD, AIR TOXICS CONTROL MEASURE FOR COMPOSITE WOOD AS TESTED IN conformance. When specific documentation or special inspection is necessary to verify compliance,that <br /> 17,commencing with Section 94520;and in areas under the jurisdiction of the Bay Area Air Quality ACCORDANCE WITH ASTM E 1333. FOR ADDITIONAL INFORMATION, SEE CALIFORNIA CODE OF method of compliance will be specified in the appropriate section or identified applicable checklist. <br /> 5.503.1.1 Woodstoves. Woodstoves and pellet stoves shall comply with U.S. EPA Phase II emission limits Management District additionally comply with the percent VOC by weight of product limits of Regulation 8 REGULATIONS, TITLE 17, SECTIONS 93120 THROUGH 93120.12. <br /> where applicable. Rule 49. 2 8 O r r 2 <br /> 2. THIN MEDIUM DENSITY FIBERBOARD HAS A MAXIMUM THICKNESS OF 5/16 INCHES (8 MM). <br />