Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Fast Lane Central Valley <br />Facility Address: <br />1 116 Roth Rd Lathrop <br />Date: <br />June 16 2016 <br />UST System Observations <br />326 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V ❑ R ❑ COS <br />327 <br />HSC 25298(b) <br />Failed to comply with temporary closure requirements <br />❑ V ❑ R ❑ COS <br />328 <br />HSC 25298(c) <br />Failed to comply with permanent closure requirements <br />❑ V ❑ R ❑ COS <br />329 <br />CCR 2636(f)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />❑ V ❑ R ❑ COS <br />Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V ❑ R ❑ COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />❑ V ❑ R ❑ COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V ❑ R ❑ COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />❑ V ❑ R ❑ COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />❑ V ❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />103 <br />HSC 25292.2 Current financial responsibility documents not submitted. <br />Financial responsibility documents submitted to CERS and the San Joaquin County Environmental Health Department <br />(EHD) are not correct. Remove 500,000 dollars per occurrence and add either 1 million dollars annual aggregate or 2 <br />million dollars annual aggregate. Note: the current Certification of Financial Responsibility terminates on 6/30/ 2016. <br />Current financial responsibility documents are required to be submitted annually. Immediately log into the California <br />Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/, and upload the required documents. <br />This is a minor violation. <br />104 <br />CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current. <br />UST Facility Operating Permit is not current in CERS. The Board of Equalization number is not valid. Any change of <br />information must be updated in CERS within 30 days of the changes. Immediately log into CERS, update the required <br />information, and submit for review by the EHD. <br />UST Tank Information forms for the underground storage tanks (UST) T1, T2, T3, T4, and T5 are not current in CERS. <br />There is no Corrosion Protection identified in CERS; T3 -beneath Vent, Vapor Recovery (VR) and Riser/Fill Pipe <br />Piping Construction, remove "Fiberglass" from the Vapor Recovery Primary and Secondary Containment since there is <br />no vapor recovery for the diesel product. For T1 and T2, beneath Vent, Vapor Recovery (VR) and Riser/Fill Pipe Piping <br />Construction, change Riser Pipe Primary Containment from Fiberglass to Steel. Any change of information must be <br />updated in CERS within 30 days of the changes. Immediately log into CERS, update the required information, and <br />submit for review by the EHD. <br />This is a repeat violation, Class II. <br />Page 3 of 4 <br />