116
>
2300 - Underground Storage Tank Program
>
PR0523684
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2023 2:59:02 PM
Creation date
9/10/2021 4:32:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0523684
PE
2351
FACILITY_ID
FA0015977
FACILITY_NAME
Fast Lane Central Valley
STREET_NUMBER
116
STREET_NAME
ROTH
STREET_TYPE
Rd
City
Lathrop
Zip
95330
APN
196-02-020
CURRENT_STATUS
01
SITE_LOCATION
116 Roth Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
418
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www,sigov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />1 <br />Date: <br />Fast Lane Central Valley <br />116 Roth Rd Lathrop <br />June 30 2015 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />207 <br />CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br />1. The designated operator failed to check and note the correct test dates for the Monitoring System Certification and <br />spill containment structure (Bucket) on the August 2014, October 2014 and January 2015 designated operator <br />monthly inspection report. During the monthly inspection, the designated operator shall check that all required <br />testing and maintenance for the UST system have been completed and document the dates they were done. Ensure <br />that designated operators performing monthly inspections at this facility are including all of the required information on <br />the reports. <br />2. The designated operator failed to document all the alarms from the attached alarm history on the Auto side: <br />November 2014, December 2014 and the Truck side: January 2015, April 2015 designated operator monthly inspection <br />report and failed to check that they were responded to appropriately. The missing alarms include: Auto: L-28 <br />November 1, 2014 (2 alarms), S-6, S-7 December 7, 2014, Truck: L-22 Alarms December 18, 23 and 25, 2014, and <br />April 5, 2015 . During the monthly inspection, the designated operator shall review the alarm history for the previous <br />month, check that each alarm was documented and responded to appropriately, and attach a copy of the alarm <br />history with documentation taken in response to any alarms to the monthly report. Ensure that designated operators <br />performing monthly inspections at this facility are including all of the required information on the reports. <br />3. The designated operator failed to attach a complete alarm history to the following DO reports: Auto & Truck <br />11/2014, 12/2014. During the monthly <br />inspection, the designated operator shall review the alarm history for the previous month, check that each alarm was <br />documented and responded to appropriately, and attach a copy of the alarm history with documentation taken in <br />response to any alarms to the monthly report. Ensure that designated operators performing monthly inspections at <br />this facility are including all of the required information on the reports. <br />This is a Class II violation. <br />209 <br />CCR 2715(f) Designated operator employee training not performed or log not kept. <br />At time of inspection the diesel fill bucket (auto side) had approximately 1/2g of diesel in it. The diesel bucket was <br />noted as having fuel in it during the 5/20/2015 DO visit. Although the training is current for employees it appears <br />employees need to have refresher training on roles with regard to spills and overfills as specified in the facility <br />response plan. The designated operator shall train facility employees for which he or she is responsible in the proper <br />operation and maintenance of the UST system once every 12 months. The training shall include, but is not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br />the training records to the EHD. <br />This is a Class II violation. <br />Received by <br />Inspector: <br />Phone <br />Date: <br />(initial): 'j <br />MICHELLE HENRY, Lead Senior RE S <br />(209).468-34 54 <br />06/30/2015 <br />Page 6 t8"-/ <br />
The URL can be used to link to this page
Your browser does not support the video tag.