My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CLUFF
>
500
>
2800 - Aboveground Petroleum Storage Program
>
PR0516579
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/13/2021 10:41:32 AM
Creation date
9/13/2021 10:35:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0516579
PE
2832
FACILITY_ID
FA0009875
FACILITY_NAME
FORD CONST CO INC
STREET_NUMBER
500
Direction
N
STREET_NAME
CLUFF
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
04934013
CURRENT_STATUS
02
SITE_LOCATION
500 N CLUFF AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Aboveground Petroleum Storage Act Inspection Report <br />Date: <br />September 08, 2021 <br /> Facility Address: <br /> 500 N CLUFF AVE, LODI <br /> Facility Name: <br /> FORD CONST CO INC <br />SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br /> 721 □ V □ R □ COSFailed to provide corrosion protection for buried pipingCFR 112.8(d)(1) <br /> 722 □ V □ R □ COSFailed to cap/blank-flange connection at transfer point and mark its origin if not in serviceCFR 112.8(d)(2) <br /> 723 □ V □ R □ COSFailed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contractionCFR 112.8(d)(3) <br /> 724 □ V □ R □ COSFailed to regularly inspect aboveground valves, piping, and appurtenancesCFR 112.8(d)(4) <br /> 725 □ V □ R □ COSFailed to conduct integrity and leak testing on buried piping any time it is worked onCFR 112.8(d)(4) <br /> 726 □ V □ R □ COSFailed to adequately warn vehicles entering facility to protect piping and other transfer operationsCFR 112.8(d)(5) <br /> 727 □ V □ R □ COSPlan failed to adequately describe overfill prevention methods for each containerCFR 112.7(a)(1), <br />112.8(c)(8) <br />Other Violations <br /> 4010 □ V □ R □ COSUnlisted Administration/Documentation violation See below <br /> 4020 □ V □ R □ COSUnlisted Training violation See below <br /> 4030 □ V □ R □ COSUnlisted Operations/Maintenance violation See below <br /> 4040 □ V □ R □ COSUnlisted Release/Leaks/Spills violation See below <br /> 4050 □ V □ R □ COSUnlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation See below <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />Overall Inspection Comments: <br />Conducted an Aboveground Petroleum Storage Act (APSA) closure inspection. Matt smylie stated the facility <br />had relocated to another location and all aboveground storage tanks had been relocated to the new facility. <br />Facility was observed from the public sidewalk through the chain link fence. No aboveground storage tanks are <br />observed on-site. This facility APSA program will be inactive. <br />To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br />of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate <br />($152). To schedule an appointment, please call (209) 468-3420. <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br />THIS FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Inspector Phone: <br /> KRISTINA SAETERN, EHS Trainee <br /> Inspector:September 08, 2021 Date: <br />Printed Name and Title: <br />Email to Matt Smylie, Environmental Contact <br />(209) 616-3045 <br />FA0009875 PR0516579 SC001 09/08/2021 <br />EHD 28-01 Rev. 9/16/2020 Aboveground Petroleum Storage Act OIRPage 4 of 4 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.