Laserfiche WebLink
1 1 <br />N UIN <br />SAN .JOA U IN Environmental Health Department <br />COUNTY Jasjit Kang, REHS, Director <br />°grFoa��P Greatness grows here. Muniappa Naidu, REHS, Assistant Director <br />PROGRAM COORDINATORS <br />Robert McClellon, REHS <br />Jeff Carruesco, REHS, RDI <br />Willy Ng, REHS <br />Michael Kith, REHS <br />Melissa Nissim, REHS <br />September 16, 2021 <br />TENENTE MICHAEL PRESTON <br />10051 ESCALON BELLOTA RD <br />ESCALON, CA 95320 <br />RE: Water Well Pump Inspection <br />Well Location: 10049 S. Escalon Bellota Road Permit #: WP0042442 Inspection Date: 09/09/2021 <br />The Environmental Health Department conducted a water well pump inspection at the above address and <br />found the following issues at the time of the inspection. In order to protect the ground water supply and your <br />water source from potential degradation, please take the associated corrective actions. <br />❑x Inadequate surface seal around wellhead: cement surface seal should drain water away from the <br />well. <br />(SJC Water Well Standards, Section 4.10. — Surface Seal) <br />Corrective Action: Repair existing or install a new concrete platform around the wellhead that <br />extends two feet in all directions from the well casing and that will drain water <br />away from the well head. <br />❑x Inadequate sanitary seal at wellhead: chlorination cap not sealed. <br />(SJC Ord. Code, Title 9, Section 9-1115.5. —Well Regulations) <br />Corrective Action: Seal all gaps and openings in the sanitary seal and around the well casing. <br />❑x Lack of or Inadequate Sampling Tap. <br />(SJC Water well Standards, Section 4.13. — Sampling Tap) <br />Corrective Action: Install a non -threaded sampling tap between the wellhead and the check valve <br />or within three (3) feet of the well head. <br />❑ Lack of or inadequate backflow prevention. <br />(SJC Water Well Standards, Section 4.14. — Backflow Prevention) <br />Corrective Action: Install an approved protective device to prevent backflow and/or back siphon <br />into a well. <br />❑ Sounding tube or air vent not sealed. <br />(SJC Water Well Standards, Section 4.13. — Sounding Tube/Air Vent Pipe) <br />Corrective Action: Sounding Tube or Fill Pipe -Install a watertight, threaded cap at the upper end <br />of the pipe. Air Vent -extend pipe 12 inches above with end inverted in a <br />downward direction and covered with 16 -mesh screening. <br />Please contact Aaron Gooderham, REHS, <br />have an questions. <br />Steven Shih, REHS <br />Program Coordinator <br />(209) 616-3062, when corrections have been made, and if you <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/ehd <br />