Laserfiche WebLink
Time In: <br /> Time Out: <br /> opQ.�tN. San Joaquin County <br /> .X Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br /> • �... P Telephone: (209)468-3420 Fax:(209)464-0138 Web:www.sigov.org/ehd <br /> �<<FORtN <br /> Underground Storage Tank Program Service Request Inspection Report <br /> Name of Facility: 3443 E CHEROKEE RD Date: 06/27/2019 <br /> Address: 3443 E CHEROKEE RD , STOCKTON 95242 <br /> Requestor: LESLIE BURNSIDE, BARGHAUSEN CONSULTING ENGINEERS INC Telephone: (858)610-0153 <br /> Program Element: 2303-UST/PIPING INSTALLATION Request#: SR0078758 <br /> Inspection Type: 131 -UST INSTALLATION INSPECTION <br /> Onsite Service Technician: Donny Gilmer ICC Service Tech/Installer Exp. Date: 12/04/2019 <br /> Manufacturer training: CSI, 11/02/19 <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> NOTES <br /> On site for the installation of new USTs <br /> -25,000 gallon Containment Solutions double-walled fiberglass tank <br /> -12,000 gallon/ 10,000 gallon Containment Solutions double-walled fiberglass split tank <br /> -Verified UL labeling on all tanks. <br /> -Inspected tanks for brine leaks. No leaks observed. <br /> -Inside of tanks was inspected by the contractor on site and stated to be clean and brine-free. <br /> -Verified the use of the manufacturer installation checklist at the time of inspection. <br /> -Verified presence of deadmen and use of anchor straps. <br /> -Verified use proper pea gravel backfill. <br /> -Witnessed tank set. The split tank brine reservoir location does not match the tank chart provided. The tank chart shows the <br /> reservoir in the center of the tank;the tank used on site has a brine reservoir on the end of the 12,000 gallon side. Deadmen <br /> location adjustments were made by the contractor based on the layout of the tank being installed. <br /> -Verified the application of additional corrosion protection on all metal anchor components. <br /> -Witnessed backfilling of the tank pit and compaction of pea gravel. <br /> —Additional inspections are required. Refer to the approval letter dated January 23, 2019 for a list of inspections needed. <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code.If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: Donny Gilmer, Installer <br /> EH Specialist: STACY RIVERA Phone: (209)468-3440 <br /> SR0078758 SC131 06/27/2019 <br /> EHD 23-01 Rev.06/30/15 Page 1 of 1 Underground Storage Tank Program Service Request Inspection Report <br />