PROJECT CODE NOTES: CONTRACTOR LIABILITY: SHEET INDEX: <br />ALL CONSTRUCTION SHALL COMPLY WTIH THE CONVENTIONAL <br />2016 CBC UNKESS OTHER WISE NOTED <br />TI -1 COVER SHEET <br />CONTRACTOR TO VERIFY SITE CONDITIONS AS THEY CONSTRUCTION LIABILITY TI -3 FLOOR PLAN <br />0000� TI -3.1 DOOR SCHEDULE <br />RELATE TO THE APPROVED SET OF PLANS, ALL CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH TI -5 FINISH FLOOR PLAN <br />DIMENSIONS MUST BE VERIFIED PRIOR TO TI -6 EQUIPMENT PLAN <br />CONSTRUCTION GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION D-1 DETAILS <br />CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE D-2 DETAILS <br />METAL STUDS SHALL BE 25 GAGE UP TO 10' AND 20 UP TO 20' RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF E-1 ELECTRCIAL POWER PLAN <br />CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS P-1 PLUMBING WASTE/VENT/GAS/WATER <br />AND PROPERTY;THAT THIS REQUIREMENT SHALL BE MADE TO APPLY PD1 PLUMBING DETAILS <br />ALL CONSTRUCTION SHALL COMPLY WITH THE CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, M-1 MECHANICAL PLAN <br />2015 IBC CODES AND COMPLY WITH ALL STATE AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, <br />AMMENDMENTS 2016 INDEMNIFY, AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY <br />1 -ALL METAL STUDS TO BE MIN 25 GAGE UON AND ALL LIABILITY, REAL, OR ALLEGED, IN CONNECTION WITH THE <br />2 -ALL WOOD SHALL BE # 2 OR BETTER PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY <br />3 -ALL STRAPS SHAL BE SIMPSON ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL. <br />4 -ALL CONCRETE SHALL MEET A MIMIMUM OF 3000 PSI <br />5 -ALL REINFORCING BARS ARE TO BE GRADE 40 <br />6 -ALL GLASS TO BE TEMPERED AS REQUIRED BY SECTION 2406 CBC NOTE <br />7 -PROVIDE GFI PROTECTION EXTERIOR OUTLETS & RESTROOM, <br />AND AT ALL SINK WITH WEALTHER PROOF THIS DESIGN IS FOR THE AREA OF ADDITION ONLY. NO <br />8 -INSTALL SMOKE DETECTORS IN THE SUPPLY SIDE OF AC UNITS 2000 WARRANTY (AND UP -GRADE) AS TO THE QUALITY OR STRUCTURAL <br />CFM AND ABOVE INTEGRITY OF THE EXISTING BUILDING OR PORTION THEREOF IS <br />9 -HEATING SYSTEMS IN THE ATTIC SHALL COMPLY WITH EITHER INFERRED OR IMPLIED BEYOND WHAT IS EXPRESSLY WRITTEN <br />THE 2013 UMC OR SHOWN ON PLANS OR CALCULATIONS. o <br />1 0 -WATER HEATERS ARE TO BE STRAFED WITH A PAN IF IN THE ATTIC <br />P,T, TO THE EXTERIOR <br />1 1 -PROVIDE PROPER COMBUSTION AIR FOR BOTH WATER <br />HEATER AND FAU s <br />12 -ALL DUCTING IS TO COMPLY WITH CHAPTER 10 UMC BE CLASS I DUCTING CODES: PROJECT DATA: <br />13 -ALL WASTE AND VENT ARE TO BE CAST IRON <br />1 4 -ALL WOOD EXSPOSED TO WEALTHER ARE TO BE PRIMED OR PRESSURE TREATED <br />1 5 -ALL GAS PIPING TO BE 6" ABOVE GRADE <br />16 -ALL HOSE BIBBS TO HAVE BACK FLOW DEVISESALL WORK SHALL COMPLY WITH: <br />1 7 -ALL EXTERIOR DOORS TO BE WEALTHER STRIPPED ZONE <br />18 -CONNECTIONS SHALL COMPLY WITH TABLE 2016 CBC APN <br />19 -PROVIDE GREEN BOARD AT TOILET ROOMS MIN 2'-0" IN FRONT 7 <br />20 -ALL TOILTS TO BE 1.28 GAL MAX 2016 CPC OCCUPANCY TYPE B <br />21 -ALL EXTERIOR PLYWOOD TO BE CDX 2016 CMC CONSTRUCTION TYPE V—B o <br />22 -MAIN DOOR TO HAVE A SIGN OVER IT " DOOR TO REMAIN UNLOCKED DURING - <br />BUSINESS HOURS. <br />2016 CEC STORIES 3 o o <br />23 -ALL DOORS WILL BE PROVIDED WITH 10" KICK PLATEA AS REQUIRED SPRINKLERS YES CRAWL SPACE g <br />24 -ALL INTERIOR FINISHES SHALL COMPLY WITH CHAPTER 8 CBC FOR MAX 2016 CGBC Q <br />FLAME SPREAD AND SMOKE DENSITY 2016 ENERGY REGS <br />25 -ALL EXIT SIGNS SHALL BE U.L. LISTED AND APPROVED TENANT SPACE 1860.00 SF <br />26 -ALL INTERIOR COUNTERS TO HAVE A MAX FINISH HEIGHT OF 34 A.F.F. <br />27 -ALL SWITCHES & T -STATS TO BE MAX 48" A.F.F TO THE TOP OF THE BOX CONSULTANTS.- <br />28 -ALL ELECTRICAL RECEPT TO BE MIN 15" A.F.F TO THE BOTTOM OF THE BOX SCOPE OF WORK: m Z m m m <br />29 -MAX HEIGH OF ALL DOOR THRESHOLDS 112'' m W w <br />Y Y <br />-ALL NEW DOORS TO HAVE LEVER TYPE HARDWARE HAMID POUYA PE REMODEL EXISTING: T <br />31 -PROVIDE TACTILE SIGNAGE AS REQUIRED PER CHAPTER 10 CBC. o g u o <br />5632 RAVENNA CT ADD A RESTAURANT WITH A DINING ROOM WITH FIXED SEATING <br />SAN JOSE, CA 95118 KITCHEN, PREP AREA. REMODEL THE RESTROOMS TO MEET ADA. g <br />IF BUILDING IS EQUIPT WITH AUTOMATIC FIRE SPRINKLERS OR HOOD & DUCT SYSTEM (408) 569-7486 <br />HPOUYA@STRUCTECH.NET <br />1. SPRINKLER CONTRACTOR TO SUBMIT 5 SET OF SPRINKLER PLANS TO THE <br />FIRE DEPT FOR APPROVAL PRIOR TO THE FIRE SPRINKLER INSTALLATION FRANK RAINONE DESIGNER Z <br />746 HEARTLAND DR F <br />MANTECA, CA 95337 <br />(209) 471-1 132 o N z iI <br />Z n p U <br />Z Q Q Q J <br />O Q Q <br />Z W U <br />O z <br />MAP LOCATION: CODE ANALYSIS: u <br />C <br />ABBREVIATIONS EGRESS ANALYSIS: <br />& AND EA EXISTING REINS REINFORCING INT. INTERIOR DINING ROOM: 40 FIXED SEATS =40 O.L. <br />FOOD PREP: 380/200 = 2 O.L. <br />L ANGLE EA EACH RHWS ROUND HEAD WOOD SCREW KEC KITCHEN EQUIP. CONTRACTOR <br />@ AT ELECT ELECTRICAL RHR RIGHT HAND REVERSE L LENGTH STORAGE: 91/300 = 1 O.L. <br />DIAMETER EQ EQUAL RM ROOM LAV LAVATORY Z <br />DEGREE EXT EXTERIOR RO ROUGH OPENING LF LINEAL FOOT TOTAL 43 O.L. <br /># POUND OR NUMBER FE FIRE EXTINGUISHER RWL RAINWATER LEADER LH LEFT HAND < <br />11]w <br />SQUARE FOOT FEC FIRE EXTINGUISHER CABINET SCD SEE CIVIL DRAWINGS LHR LEFT HAND REVERSED <br />Lu <br />AB ANCHOR BOLT FHWS FLAT HEAD WOOD SCREW SCH SECTION MAX MAXIMUM ONE EXITS REQUIRED x J v = <br />ACOUS ACOUSTIC FIN FINISH SED SEE ELECTRICAL DRAWINGS MB MACHINE BOLT <br />ACT <br />Z <br />ACOUSTIC CEILING TILE FLR FLOOR SIM SIMILAR MECH MECHANICAL Zo <br />ACH ABOVE COUNTER HEIGHT FOC FURNISHED BY OWNER SMD w p SEE MECHANICAL DRAWINGS MFR MANUFACTURER E MINER AVE ST WOL � � Q <br />AFF ABOVE FINISHED FLOOR INSTALLED BY CONTRACTOR SMS SHEET METAL SCREW MIN MINIMUM <br />ALUM ALUMINUM FOS FACE OF STUD SPD SEE PLUMBING DRAWINGS MISC. MISCELLANEOUS <br />ARCH ARCHITECTURAL, ARCHITECT FOSTL FACE OF STEEL SPEC SPECIFICATIONS MIW MAL IRON WASHER N � <br />BID BOARD FRP FIBERGLASS REINFORCED PANEL S/S STAINLESS STEEL MOD MODULAR p � p <br />BLDG BUILDING FT FOOT FEET STD STANDARD MTD MOUNTED N <br />BLKG BLOCKING FTG FOOTING NG STL STEEL R — ? <br />MTL METAL H REQUIRED PLUMBING FIXTURE COUNT PER SECTION 422 CPC <br />v7 J <br />BM BEAM GA GAUGE STS SELF TAPPING SCREW (N) NEW O Z TOTAL OCCUPANT LOAD IS AS FOLLOWS <br />LLJ <br />BOT BOTTOM GALV GALVANIZED T&G TONGUE & GROVE NIC NOT IN CONTRACT <br />BUR BUILT-UP ROOFING GSM GALVANIZED SHEET METAL TOP TOP OF PAVEMENT NOM NOMINAL <br />CENTER LINE GWB GYPSUM WALLBOARD TOF TOP OF FLOOR NTS NOT TO SCALE ® Q 1860/60= 31 TOTAL O.L. LESS AND 50 ONLY ONE RESTROOM REQUIRED BY SECTION 422.1 & 422.2 CPC. <br />CLG CEILING GYP GYPSUMTOS TOP OF SLAB/STEEL OC ON CENTER w = <br />COL COLUMN H OR HGT HEIGHT TOW TOP OF WALL OD OUTSIDE DIAMETER z 125 BRIDGE PL. w sE <br />COMP COMPOSITE HB HOSE BIB TS TUBE STEEL PDP POWDER DRIVEN PIN <br />CONT CONTINUOUS HHS HEX HEAD SCREW TYP TYPICAL PH PANIC HARDWARE <br />CPT CARPET HM HOLLOW METAL UNO UNLESS NOTED OTHERWISE SHOWN <br />DBLL PLATE <br />D wxe NO. <br />DOUBLE HORIZ HORIZONTAL VCT VINYL PLF PER LINAL FOOT <br />DET DETAIL HVAC HEATING -VENTILATION- VERT VERTICAL PLAM PLASTIC LAMINATE n -I <br />DIM DIMENSION AIR CONDITIONING W WIDTH PLYWD PLYWOOD <br />DSA DIVISION OF STATE ARCHITECT ID INSIDE DIAMETER W/ WITH PR PAIR <br />DWG DRAWING WD WOOD PSF POUNDS PER SQUARE FOOT <br />OF <br />