ENTRANCE -FRONT APPROACHVESTIBULEREQUIRED LEVEL& CLEAR SPACE48" MIN.5'-0"5'-0"4'-0"32" CLR. 1'-0"2'-0" MIN. EXTERIOR1'-6" MIN. INTERIOR32" MIN. 1'-6"54" MIN.REQUIRED LEVEL& CLEAR SPACELEVER* MOUNT HARDWARE 2'-10" TO 3'-8" A.F.F.PUSH -PULL**NOTE:PUSH-PULL HANDLES AND CLOSERS TO BE SINGLE-ACTION ACTIVATED WITH 5 LBS PRESSURE MAXIMUM.FIRE-RATED DOORS EXCLUDED.FLUSH ACTIVATOR ON WIDE SIDE36" MIN. GRAB BAR60" x 60" LEVEL AND CLEAR LANDING30"x48" CLEAR SPACE60" MIN. DIAMETER CLEAR42" MIN. GRAB BARW.C.W.C.W.C.W.C.LAV.LAV.LAV.CLR.34" MIN.CLR.48" MIN.MIN.1'-0"CLR.32" MIN.17"-18"MOUNTED WATER CLOSET59" MIN. @ FLOORMOUNTED WATER CLOSET56" MIN. @ WALL60" MIN.MANEUVERING SPACE60" MIN. @ SIDE DOOR35"-37"MIN.5'-0"42" MIN. GRAB BARCLR.32" MIN.SIDE ELEVATIONPLANFRONT ELEVATIONCONT. 5" HIGH (MIN.) SMOOTH, HARD, NON-ABSORBENT BASEMIN. 48" HIGH WAINSCOT OF A SMOOTH, HARD, & NON-ABSORBENT SURFACE1-1/2" DIA X 36" GRAB BAR - 1-1/2" CLR. TO WALL17"-19" TO TOP OF SEAT (2" MAX. HGT.)TPHMIN. 48" HIGH WAINSCOT1 1/2" DIA X 36" GRABBAR - 1 1/2" CLR. TO WALL1 1/2" DIA X 42" GRAB BAR - 1 1/2" CLR. TO WALLFLUSH ACTIVATORON WIDE SIDEW.C.FLUSH VALVECONTROL ON WIDESIDE OF TOILETAREA - MAX. FORCETO ACTIVATE TO BELESS THAN 5 lbf.MIN2'-0"17"-19"MIN1'-0"1-1/2" DIA X 36" GRAB BAR -1-1/2" CLR. TO WALL19".33"-36"9" MAX.7" MIN.TOP OF GRIPPING SURFACEMAX1'-0".MIN2'-0"54" MINPLANELEVATIONFLUSH VALVE CONTROL MOUNTED AT +44" MAX.- MAX. FORCE TO ACTIVATE SHALL BE LESS THAN 5 LBS.48" HIGH (MIN.) WAINSCOTCLEAR FLOOR SPACEURINALFACE OF ADJACENT WALL9"MIN.4'-0"MIN.2'-6"MAX.1'-5"MIN. MAX.14" - 17"KNEE CLEARANCE BOUNDARYPLANSECTIONFLR.TRAP ENCLOSUREEDGE OF COUNTERCLEAR FLOOR SPACEFAUCET CONTROLS SHALL BE OF A LEVER TYPE AND THE MAX. FORCE TO ACTIVATE CONTROLS SHALL BE LESS THAN 5 LBS.NOTE:ALL PIPING UNDERNEATH LAVATORIES SHALL BE INSULATED OR COVEREDLAV.MIN.9"MIN.2'-3"MIN.2'-5"MAX.2'-10"MAX.6"MIN.8"17" MIN.FACE OF ADJACENT WALLMIN.2'-6"MAX.6"MIN.4'-0"MAX.1'-6"MIN1'-6"FINISHED SURFACETPHSND SCDSDWRPTDMAXIMUM HEIGHT TO HIGHEST OPERABLE PART OR OPNG. SLOTS OF ALL DISPENSERSHDBCSPT/WRMIRROR48" HIGH (MIN.) WAINSCOT -WHERE OCCURSTO BOTTOM OFREFLECTIVESURFACEMAX.3'-4"A.F.F.1/4" = 1'-0"G2.01WHEEL CHAIR ACCESS1/4" = 1'-0"G2.02DOOR HARDWARE1/4" = 1'-0"G2.018MULTIPLE ACCOMODATION TOILET1/4" = 1'-0"G2.010WATER CLOSET1/4" = 1'-0"G2.05URINAL1/4" = 1'-0"G2.015LAVATORY COUNTER1/4" = 1'-0"G2.013ELEVATION OF TOILET ACCESSORIESChecked By:Drawn By:Project No.:NJ ASSOCIATES22769 N BENDER ROADACAMPO CA 95220209.727.2040www.njaarchitecture.comCLIENTPROJECTARCHITECT10-31-2019REVISIONSARCHITECTS STAMPPhoenix Tea and Wine Inc5546 Vintage CirStockton, CA4/25/2018 10:49:32 AMACCESSIBILITY DETAILS +STANDARDSG2.0EMJV18012PERMIT4/25/18PHOENIX TEA AND WINE INC.TENANT IMPROVEMENTSSAM SHI40 DOWNTOWN MALLLODI CA1. ALL ENTRANCES AND EXTERIOR GROUND-FLOOR EXIT DOORS TO BUILDINGS AND FACILITIES SHALL BE MADE ACCESSIBLE TO PERSONS WITH DISABILITIES. DOORWAYS SHALL HAVE A MINIMUM CLEAR OPENING OF 32 INCHES WITH THE DOOR OPEN 90 DEGREES, MEASURED BETWEEN THE FACE OF THE DOOR AND THE OPPOSITE STOP (SECTIONS 1008.1.1, 11B-404.2 AND 11B-404.2.3). 2. HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 34 INCHES AND 44 INCHES ABOVE THE FLOOR. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER-TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY OT GRASP THE OPENING HARDWARE. LOCKED EXIT DOORS SHALL OPERATE AS ABOVE IN EGRESS DIRECTION (SECTIONS 1008.1.9 AND 11B-404.2.7). 3. PANIC HARDWARE: WHERE INSTALLED, SHALL COMPLY WITH THE REQUIREMENTS OF CBC 1008.1.10.1. THE ACTIVATING MEMBER SHALL BE MOUNTED AT A HEIGHT OF NOT LESS THAN 34 INCHES OR MORE THAN 44 INCHES ABOVE THE FLOOR. THE UNLATCHING FORCE SHALL NOT EXCEED 15 POUNDS WHEN APPLIED IN THE DIRECTION OF TRAVEL. (SECTION 1008.1.10, 1008.1.10.1, AND 11B-404.2.9). 4. WIDTH AND HEIGHT: EVERY REQUIRED EXIT DOORWAY SHALL BE OF A SIZE AS TO PERMIT THE INSTALLATION OF A DOOR NOT LESS THAN 3 FEET IN WIDTH AND NOT LESS THAN 6 FEET, 8 INCHES IN HEIGHT WHEN INSTALLED IN EXIT DOORWAYS. EXIT DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES AND SHALL BE SO MOUNTED THAT THE CLEAR WIDTH OF THE EXIT WAY IS NOT LESS THAN 32 INCHES (SECTIONS 1008.1.1 AND 11B-404.2.). 5. HINGED DOORS: THE OPENING WIDTH SHALL BE MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. WHERE A PAIR OF DOORS IS UTILIZED, AT LEAST ONE OF THE DOORS SHALL MEET THIS OPENING REQUEMENT. REVOLVING DOORS SHALL NOT BE USED AS A REQUIRED ENTRANCE FOR PERSONS WITH DISABILITIES (SECTIONS 11B-404.2.1, 11B-404.2.2 AND 11B-404.2.3). 6. THE MAXIMUM WIDTH OF A SWINGING DOOR LEAF SHALL NOT EXCEED 48 INCHES (SECTION 1008.1.1). 7. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS, SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. WHEN FIRE DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED NOT TO EXCEED 15 POUNDS (SECTIONS 1008.1.3, 1008.1.3.1 AND 11B-404.2.9). 8. DOOR AND GATE SURFACES: SWINGING DOOR AND GATE SURFACES WITHIN 10 INCHES OF THE FINISH FLOOR OR GROUND MEASURED VERTICALLY SHALL HAVE A SMOOTH SURFACES ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE. PARTS CREATING HORIZONTAL OR VERTICAL JOINTS IN THESE SURFACES SHALL BE WITHIN 1/16" INCH OF THE SAME PLANE AS THE OTHER AND BE FREE OF SHARP OR ABRASIVE EDGES. CAVITIES CREATED BY ADDED KICK PLATES SHALL BE CAPPED (SECTIONS 11B-404.2.10). 9. THRESHOLDS SHALL NOT EXCEED 1/2 INCHES IN HEIGHT, WITH A MAXIMUM 1/4-INCH VERTICAL AND CHANGES IN LEVEL BETWEEN 1/4 INCH AND 1/2 INCH SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2 (50% SLOPE) (SECTION 11B-404.2.5). 10. EXIT DOORS FROM GROUP 'A' OCCUPANCY SHALL NOT BE PROVIDED WITH A LATCH OR LOCK UNLESS IT IS PANIC HARDWARE (SECTION 1008.1.10). 11. RECESSED DOORMATS SHALL BE ADEQUATELY ANCHORED TO PREVENT INTERFERENCE WITH WHEELCHAIR TRAFFIC (SECTION 11B-302.1 AND 11B-302.2). 12. ALL GATES, INCLUDING TICKET GATES, SHALL MEET ALL APPLICABLE SPECIFICATIONS FOR DOORS (SECTION 11B-404.1 AND 11B-404.2). 13. DOOR CLOSING SPEED: DOOR AND GATE CLOSING SPEED SHALL COMPLY WITH SECTION 11B-404.2.8. DOOR CLOSERS AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGRESS, THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 DEGREES FROM THE LATCH IS 5 SECONDS MINIMUM. DOOR AND GATE SPRING HINGES SHALL BE ADJUSTED SO THAT FROM THE OPEN POSITION OF 70 DEGREES, THE DOOR OR GATE SHALL MOVE TO THE CLOSED POSITION IN 1.5 SECONDS MINIMUM. (SECTIONS 11B-404.2.8.1 AND 11B-404.2.8.2). 14. THE WATER CLOSET COMPARTMENT SHALL BE EQUIPPED WITH A DOOR THAT HAS AN AUTOMATIC-CLOSING DEVICE, AND SHALL HAVE A CLEAR, UNOBSTRUCTED OPENING WIDTH OF 34 INCHES. 15. THE INSIDE AND OUTSIDE OF THE COMPARTMENT DOOR SHALL BE EQUIPPED WITH A LOOP OR U-SHAPED HANDLE IMMEDIATELY BELOW THE LATCH. THE LATCH SHALL BE FLIP-OVER STYLE, SLIDING OR OTHER HARDWARE NOT REQUIRING THE USER TO GRASP OR TWIST. 16. EXCEPTION: IN GROUPS A, DIVISION 3, B, F, M, AND S OCCUPANCIES AND IN ALL CHURCHES, KEY-LOCKING HARDWARE MAY BE USED ON THE MAIN EXIT WHEN THE MAIN EXIT CONSISTS OF A SINGLE DOOR OR PAIR OF DOORS IF THERE IS A READILY VISIBLE, DURABLE SIGN ON OR ADJACENT TO THE DOOR STATING "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS". THE SIGN SHALL BE IN LETTERS NOT LESS THAN 1 INCH ON A CONTRASTING BACKGROUND. WHEN UNLOCKED, THE SINGLE DOOR OR BOTH LEAVES OF A PAIR OF DOORS MUST BE FREE TO SWING WITHOUT OPERATION OF ANY LATCHING DEVICE. THE USE OF THIS EXCEPTION MAY BE REVOKED BY THE BUILDING OFFICIAL [FOR HCD 1&2] ENFORCING AGENCY FOR DUE CAUSE. 17. EXIT DOORS SHALL BE FURNISHED & INSTALLED WITH HARDWARE ALLOWING DOOR TO BE OPENED FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. PAIRS OF EXIT DOORS SHALL BE FURNISHED & INSTALLED WITH APPROVED AUTOMIAC FLUSH BOLTS ON ONE OF THE DOOR LEAVES AND NO SURFACE MOUNTED HARDWARE INSTALLED ON SAME LEAF. THE UNLATCHING OF BOTH DOOR LEAVES SHALL NOT REQUIRE MORE THAN ONE OPERATION. 1. ANY PATH OF TRAVEL SHALL BE CONSIDERED A RAMP IF ITS SLOPE IS GREATER THAN 1 FOOT OF VERTICAL RISE IN 20 FEET OF HORIZONTAL RUN (5% GRADIENT). THE LEAST POSSIBLE SLOPE SHALL BE USED FOR ANY RAMP (SECTION 11B-405.2). 2. WIDTH: PRIMARY ENTRANCE AND SPECIAL OCCUPANCY, PEDESTRIAN RAMPS SERVING PRIMARY ENTRANCES TO BUILDINGS HAVING AN OCCUPANT LOAD OF 300 OR MORE SHALL HAVE A MINIMUM CLEAR IN WIDTH OF 60 INCHES. RAMPS SERVING GROUP R OCCUPANCIES MAY BE 36 INCHES CLEAR WIDTH WHEN THE OCCUPANT LOAD IS 50 OR LESS. ALL OTHER PEDESTRIAN RAMPS SHALL HAVE A MINIMUM WIDTH OF 48 INCHES (SECTION 11B-405.5). 3. SLOPE: THE MAXIMUM SLOPE OF A RAMP THAT SERVES ANY EXIT WAY THAT PROVIDES ACCESS FOR PERSONS WITH PHYSICAL DISABILITIES OR IS IN THE PATH OF TRAVEL SHALL BE 1 FOOT OF VERTICAL RISE IN 12 FEET OF HORIZONTAL RUN (8.3% MAX. GRADIENT) (SECTION 11B-405.2). THE CROSS SLOPE OF RAMP SURFACES SHALL BE NO GREATER THAN 1 UNIT VERTICAL IN 48 UNITS HORIZONTAL (SECTION 11B-405.3). 4. A CURB, 2 INCHES HIGH MINIMUM, OR BARRIER SHALL BE PROVIDED THAT PREVENTS THE PASSAGE OF A 4 INCH DIAMETER SPHERE, WHERE ANY PORTION OF THE SPHERE IS WITHIN 4 INCHES OF THE FINISH FLOOR OR GROUND SURFACE. TO PREVENT WHEEL ENTRAPMENT, THE CURB OR BARRIER SHALL PROVIDE A CONTINUOUS AND UNINTERRUPED BARRIER ALONG THE LENGTH OF THE RAMP. DOORS & HARDWARERAMPSSANITARY FACILITIES IDENTIFICATION1. PASSAGEWAYS LEADING TO SANITARY FACILITIES SHALL HAVE A CLEAR ACCESS AS SPECIFIED IN SECTION 11B-402. ALL DOORWAYS LEADING TO SUCH SANITARY FACILITIES SHALL HAVE: A. AN UNOBSTRUCTED CLEAR OPENING WIDTH OF 32 INCHES (813 MM). B. A LEVEL AND CLEAR AREA NOT LESS THAN REQUIRED (TABLE AND FIGURE 11B-404.2.4.1) 1. BATHING FACILITIES ( NOT APPLICABLE).2. TOILET FACILITIES ( SECTION 11B-603). A. MULTIPLE-ACCOMMODATION TOILET FACILITITIES SHALL HAVE THE FOLLOWING: a. CLEAR SPACE: A WATER CLOSET FIXTURE LOCATED IN A COMPARTMENT SHALL PROVIDE A MINIMUM 17 INCHES AND 18 INCHES MAXIMUM FROM THE CENTERLINE OF THE WATER CLOSET TO THE WALL, EXCEPT THAT THE WATER CLOSET SHALL BE A MINIMUM 17 INCHES AND 19 INCHES MAXIMUM FROM THE CENTERLINE OF WATER CLOSET TO THE WALL IN AMBULATORY ACCESSIBLE TOILET COMPARTMENTS. A MINIMUM 48 INCHES LONG CLEAR SPACE SHALL BE PROVIDED IN FRONT OF THE WATER CLOSET IF THE COMPARTMENT HAS AN END-OPENING DOOR (FACING THE WATER CLOSET). A MINIMUM 60 INCH LONG CLEAR SPACE SHALL BE PROVIDED IN A COMPARTMENT WITH THE DOOR LOCATED AT THE SIDE AND OPENING OUT. GRAB BARS SHALL NOT PROJECT MORE THAN 3 INCHES IN THE CLEAR SPACES AS SPECIFIED ABOVE. b. COMPARTMENT DOORS: WATER CLOSET COMPARTMENT SHALL BE EQUIPPED WITHA DOOR THAT HAS AN AUTOMATIC-CLOSING DEVICE, AND SHALL HAVE A CLEAR, UNOBSTRUCTED OPENING WIDTH OF 32 INCHES WHEN LOCATED AT THE END AND 34 INCHES WHEN LOCATED AT THE SIDE WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION (SECTION 11B-604.8.1.2). 3 THE INSIDE AND OUTSIDE OF THE COMPARTMENT DOOR SHALL BE EQUIPPED WITH A LOOP OR U-SHAPED HANDLE IMMEDIATELY BELOW THE LATCH, MOUNTING HEIGHT OF 34 INCHES TO 44 INCHES A.F.F. THE LATCH SHALL BE FLIP-OVER STYLE, SLIDING, OR OTHER HARDWARE NOT REQUIRING THE USER TO GRASP OR TWIST. EXCEPT FOR DOOR-OPENING WIDTHS AND DOOR SWINGS, A CLEAR, UNOBSTRUCTED ACCESS OF NOT LESS THAN 44 INCHES SHALL BE PROVIDED TO WATER CLOSET COMPARTMENTS DESIGNED FOR USE BY PERSONS WITH DISABILITIES AND THE SPACE IMMEDIATELY IN FRONT OF A WATER CLOSET COMPARTMENT SHALL NOT BE LESS THAN 48 INCHES (1219 MM) AS MEASURED AT RIGHT ANGLES TO COMPARTMENT DOOR IN ITS CLOSED POSITION. 1. GRAB BARS A. LOCATION: GRAB BARS LOCATED ON EACH SIDE, OR ONE SIDE AND THE BACK OF THE ACCESSIBLE TOILET STALL OR COMPARTMENT, SHALL BE SECURELY ATTACHED 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE AND PARALLEL TO THE FLOOR. SIDE GRAB BARS SHALL BE 42 INCHES MINIMUM LOCATED 12 INCHES MAXIMUM FROM REAR WALL, EXTENDING 54 INCHES MINIMUM FROM THE REAR WALL WITH THE FRONT END POSITIONED 24 INCHES IN FRONT OF THE WATER CLOSET STOOL. REAR GRAB BARS SHALL BE 36 INCHES LONG MINIMUM AND EXTEND FROM THE CENTERLINE OF WATER CLOSET 12 INCHES MINIMUM ON ONE SIDE AND 24 INCHES MINIMUM ON THE OTHER SIDE(SECTIONS 11B 609.4., 11B-604.5.1 AND 11B-604.5.2). B. DIAMETER OR WIDTH: THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB BAR SHALL BE 1-1/4 INCHES TO 2 INCHES (32 MM TO 38 MM) OR THE SHAPE SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE. IF GRAB BARS ARE MOUNTED ADJACENT TO A WALL, THE SPACE BETWEEN THAT WALL AND GRAB BARS SHALL BE 1-1/2 INCHES (38 MM). SEE FIGURE 11B-609.2.2 (11B-609.2).C. STRUCTURAL STRENGTH: THE STRUCTURAL STRENGTH OF GRAB BARS, TUB AND SHOWER SEATS, FASTENERS, AND MOUNTING DEVICES SHALL MEET THE REQUREMENTS IN SECTIONS 11B-609.8. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. (SECTION 11B-609.6) D. SURFACE: A GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT TO IT SHALL BE FREE OF ANY SHARP OR ABRASIVE ELEMENTS. EDGES SHALL HAVE A MINIMUM RADIUS OF 1/8 INCH (3.2 MM). (SECTION 11B-609.5) 1. TOILET ROOM FIXTURES AND ACCESSORIES A. LAVATORY FIXTURES: A CLEAR FLOOR SPACE 30 INCHES BY 48 INCHES SHALL BE PROVIDED IN FRONT OF A LAVATORY TO ALLOW A FORWARD APPROACH. SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE AND SHALL EXTEND A MAXIMUM OF 19 INCHES INTO KNEE AND TOE SPACE UNDERNEATH THE LAVATORY. (SECTIONS 11B-305.3 AND 11B-306.2.2, EXCEPTION) B. MIRRORS SHALL BE MOUNTED WITH THE BOTTOM EDGE OF THE REFLECTIVE SURFACE NO HIGHER THAN 40 INCHES FROM THE FLOOR. MIRRORS NOT LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL BE MOUNTED WITH THE BOTTOM EDGE OF THE REFLECTIVE SURFACE NO HIGHER THAN 35 INCHES FROM THE FLOOR (SECTION 11B-603.3).C. WHERE TOWEL, SANITARY NAPKINS,, WASTE RECEPTACLE, AND OTHER SIMILAR DISPENSING AND DISPOSAL FIXTURES ARE PROVIDED, AT LEAST ONE OF EACH TYPE SHALL BE LOCATED WITH ALL OPERABLE PARTS, INCLUDING COIN SLOTS, WITHIN 40 INCHES FROM THE FINISHED FLOOR (SECTION 11B-603.5). D. TOILET TISSUE DISPENSERS SHALL BE LOCATED ON THE WALL WITHIN 7-9 INCHES OF THE FRONT EDGE OF THE TOILET SEAT, MOUNTED BELOW THE GRAB BAR, AT A MINIMUM HEIGHT OF 19 INCHES. DISPENSERS THAT CONTROL DELIVERY OR THAT DO NOT PERMIT CONTINUOUS PAPER FLOW SHALL NOT BE USED. LIMIT THE PROJECTION OF A SURFACE OR SEMI-RECESSED MOUNTED DISPENSER FROM ENCROACHING MORE THAN 3 INCHES FROM THE FACE OF THE WALL OR PARTITION, AND NO CLOSER THAN 1-1/2 INCHES TO THE TANGENT POINT OF THE GRAB BAR (SECTION 11B-604.7). E. WHERE URINALS ARE PROVIDED, AT LEAST ONE SHALL HAVE A CLEAR FLOOR SPACE 30 INCHES BY 48 INCHES IN FRONT OF THE URINAL TO ALLOW FORWARD APPROACH (SECTION 11B-605.3). 1. DOORWAYS LEADING TO MEN'S SANITARY FACILITIES SHALL BE INDENTIFIED BY AN EQUILATERAL TRIANGLE 1/4 INCH THICK WITH EDGES 12 INCHES LONG AND A VERTEX POINTING UPWARD. WOMEN'S SANITARY FACILITIES SHALL BE IDENTIFIED BY A CIRCLE, 1/4 INCH THICK AND 12 INCHES IN DIAMETER. UNISEX SANITARY FACILITIES SHALL BE IDENTIFIED BY A CIRCLE 1/4 INCH THICK, 12 INCHES IN DIAMETER WITH A 1/4 INCH THICK TRIANGLE SUPERIMPOSED ON THE CIRCLE AND WITHIN THE 12 INCH DIAMETER. THESE GEOMETRIC SYMBOLS SHALL BE CENTERED ON THE DOOR AT A HEIGHT OF 60 INCHES AND THEIR COLOR AND CONTRAST SHALL BE DISTINCTLY DIFFERENT FROM THE COLOR AND CONTRAST OF THE DOOR. 2. SEE ACCESSIBLITY SIGNAGE CRITERIA FOR ADDITIONAL REQUIREMENTS. BATHING AND TOILET FACILITIES 1. INTERNATIONAL SYMBOL OF ACCESSIBILITY: THE FOLLOWING ELEMENTS AND SPACES OF ACCESSIBLE FACILITIES SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY: A. ACCESSIBLE PARKING SPACES. B. ACCESSIBLE AREA OF REFUGE.C. ACCESSIBLE PASSENGER LOADING ZONES. D. ACCESSIBLE TOILET AND BATHING FACILITIES. E. ALL MAIN ENTRY DOORS. 1. OTHER SIGNS: INACCESSIBLE BUILDING ENTRANCES, INACCESSIBLE PUBLIC TOILETS AND BATHING FACILITIES, AND ELEVATORS NOT ON AN ACCESSIBLE ROUTE SHALL BE PROVIDED WITH DIRECTIONAL SIGNAGE INDICATING THE ROUTE TO THE NEARST SIMILAR ACCESSIBLE ELEMENT (SECTIONS 11B-216.3, 11B-216.6 AND 11B-216.9.2)) A. AT EXITS SERVING A REQUIRED ACCESSIBLE SPACE, BUT NOT PROVIDING AN APPROVED ACCESSIBLE MEANS OF EGRESS, SIGNS SHALL BE INSTALLED INDICATING THE LOCATION OF ACCESSIBLE MEANS OF EGRESS. (SECTION 11B-216.4.3) 1. DESIGN: THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARD USED TO INDENTIFY FACILITIES THAT ARE ACCESSIBLE TO AND USABLE BY PHYSICALLY DISABLED PERSONS AS SET FORTH IN THESE BUILDING STANDARDS AND AS SPECIFICALLY REQURED IN THESE NOTES (SECTION 11B-703.7.2.1). 2. COLOR OF SYMBOL: THE SYMBOL SPECIFIED ABOVE SHALL CONSIST OF A WHITE FIGURE ON A BLUE BACKGROUND. THE BLUE SHALL BE EQUAL TO COLOR NO. 15090 IN FEDERAL STANDARD 595B. (SECTION 11B-703.7.2.1) A. EXCEPTION: THE APPROPRIATE ENORCEMENT AGENCY MAY APPROVE SPECIAL SIGNS AND IDENTIFICATION NECESSARY TO COMPLEMENT DECOR OR UNIQUE DESIGN WHEN IT IS DETERMINED THAT SUCH SIGNS AND IDENTIFICATION PROVIDE ADEQUATE DIRECTION TO PERSONS WITH DISABILITIES.(SECTION 11B-703.7.2.1, EXCEPTION)3. CONTRAST AND FINISH: CHARACTER AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND. THE (FINISH OF) CHARACTERS AND BACKGROUND OF SIGNS SHALL BE EGGSHELL, MATTE, OR OTHER NON-GLARE FINISH (SECTION 11B-703.5.1 AND 11B-703.7.1). 4. PROPORTIONS: CHARACTERS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER "O" IS 60 PERCENT MINIMUM AND 110 PERCENT MAXIMUM OF THE HEIGHT OF THE UPPERCASE LETTER "I" (SECTION 11B-703.5.4). 5. CHARACTER HEIGHT: MINIMUM CHARACTER HEIGHT SHALL COMPLY WITH TABLE 11B-703.5.5. VIEWING DISTANCE SHALL BE MEASURED AS THE HORIZONTAL DISTANCE BETWEEN THE CHARACTER AND AN OBSTRUCTION PREVENTING FURTHER APPROACH TOWARDS THE SIGN. CHARACTER HEIGHT SHALL BE BASED ON THE UPPERCASE LETTER "I" (SECTION 11B-703.5.5). 6. WHERE PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES, RAISED LETTERS SHALL ALSO BE PROVIDED AND SHALL BE ACCOMPANIED BY BRAILLE (SECTION 11B-703.2). 7. RAISED CHARACTERS AND PICTORIAL SYMBOL SIGNS: WHEN RAISED CHARACTERS OR SYMBOLS ARE USED, THEY SHALL CONFORM TO THE FOLLOWING REQUIREMENTS (11B-703.2 AND 11B-703.4). A. CHARACTER TYPE: LETTERS AND NUMBERS ON SIGNS SHALL BE RAISED 1/32 INCH MINIMUM AND SHALL BE SANS-SERIF UPPERCASE CHARACTERS ACCOMPANIED BY GRADE 2 BRAILLE. (SECTION 11B-703.2.1, 11B-703.2.3 AND 11B-703.3) B. CHARACTER SIZE: RAISED CHARACTERS OR SYMBOLS SHALL BE A MINIMUM OF 5/8 INCH HIGH TO A MAXIMUM HEIGHT OF 2 INCHES. (SECTION 11B-703.2.5) C. PICTORIAL SYMBOL SIGNS (PICTOGRAMS NONGEOMETRIC): PICTORIAL SYMBOL SIGNS (PICTOGRAMS) SHALL BE ACCOMPANIED BY THE EQUIVALENT VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAM. THE BORDER DIMENSION OF THE PICTOGRAM SHALL BE A MINIMUM OF 6 INCHES IN HEIGHT. (SECTION 11B-703.6.1) D. CHARACTER PLACEMENT: CHARACTERS AND BRAILLE SHALL BE IN A HORIZONTAL FORMAT. BRAILLE SHALL BE PLACED A MINIMUM OF 3/8 INCH AND A MAXIMUM OF 1/2 INCH DIRECTLY BELOW THE TACTILE CHARACTERS (FLUSH LEFT OR CENTERED). WHEN TACTILE TEXT IS MULTILINED, ALL BRAILLE SHALL BE PLACED TOGETHER BELOW ALL LINES OF TACTILE TEXT. (SECTION 11B-703.3.2) 1. BRAILLE: CONTRACTED (GRADE 2) BRAILLE SHALL BE USED WHEREVER BRAILLE IS REQUIRED IN OTHER PORTIONS OF THESE STANDARDS. DOTS SHALL BE 1/10 INCH ON CENTER IN EACH CELL WITH 2/10 INCH SPACE BETWEEN CELLS DOTS SHALL BE RAISED A MINIMUM OF 1/40 INCH ABOVE THE BACKGROUND. BRAIL DOTS SHALL BE DOMED OR ROUNDED (TABLE 11B-703.3.1). 2. MOUNTING LOCATION AND HEIGHT: WHERE PERMANENT IDENTIFICATION SIGNS ARE PROVIDED FOR ROOMS AND SPACES, SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR ON THE APPROACH SIDE OF THE DOOR AS ONE ENTERS THE ROOM OR SPACE. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT. SIGNS CONTAINING TACTILE CHARACTERS SHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE OF 18 INCHES MINIMUM BY 18 INCHES MINIMUM, CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN POSITION. TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST BRAILLE CELLS AND 60 INCHES MAXIMUM ABOVE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE HIGHEST LINE OF RAISED CHARACTERS. (SECTION 11B-703.4.1 AND 11B-703.4.2). 3. ENTRANCE SIGNS: ALL BUILDING ENTRANCES THAT ARE ACCESSIBLE TO AND USABLE BY PERSONS WITH DISABILITIES SHALL BE INDENTIFIED WITH AT LEAST ONE INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN AND WITH ADDITIONAL DIRECTIONAL SIGNS (UTILIZING THE SYMBOL), AS REQUIRED AT JUNCTIONS WHERE THE ACCESSIBLE ROUTE OF TRAVEL DIVERGES FROM THE REGULAR CIRCULATION PATH, TO BE VISIBLE TO PERSONS ALONG APPROACHING CIRCULATION PATHS. (SECTION 11B-216.6) ACCESSIBILITY SIGNAGENo. Description Date By