My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
1810
>
1600 - Food Program
>
PR0547120
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/12/2021 4:35:14 PM
Creation date
10/1/2021 1:39:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0547120
PE
1624
FACILITY_ID
FA0026728
FACILITY_NAME
STARBUCKS COFFEE #5470
STREET_NUMBER
1810
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
1810 PACIFIC AVE
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PVC EXHAUST HEADER <br /> PVC SCH 40 TEE OR EL (TYPICAL) 1. FINISH GRADE OF MULCH LAYER 'r' <br /> > 7M-11 <br /> 7 2. MULCH TOP DRESSING PER <br /> PLANTING PLAN - - 1 <br /> �_ _ _ 1. FINISH GRADE <br /> FP _ _ _ _ _ 3. POLY TUBING PER IRRIGATION 2. 7" ROUND PLASTIC =III=III- 3" I=I I=III=III= <br /> I :III=III=III-_-III-II III= 1 �III=III= _�_ 1 LEGEND _ _ -_ -_ -_ 2 <br /> BARB X MALE FITTING: 3"-4" -III-III-III-_-III-I I III= III=III=III= - 4. FINISH GRADE VALVE BOX WITH =III-III-I I _ <br /> :1 I 1=III=III=III=-I I -I I = 2 _ _ _-� 2 5. STEEL TUBING-SOIL STAPLE SNAP-ON LID (RAIN =III=III =III=III=III= <br /> RAIN BIRD XFF-MA FITTING (TYPICAL) _ ! _ =I I I=III-III- BIRD vB_7RNpBK <br /> 2 - FLUSH POINT (TYPICAL) III-III -1 I E (NETAFIM TLS6 OR APPROVED EQUAL) =III-III-I I _ _ <br /> SEE RAIN BIR DETAIL "XFS FLUSH POINT" OR "XFS FLUSH 3 J 3 I= - - 6. NATIVE SOIL OR APPROVED -III-III III=III=III= <br /> POINT WITH BALL VALVE" _ _ 7. DEPTH OF MULCH PER PLANTING EQUAL)HEAT =III-III-I - 4 ©2017 STARBUCKS COFFEE COMPANY <br /> -III-I I I-I I I I I-III-_-I -I I I-I I- I I-III- BRAND"FV"ON LID =III=III III=III=III= <br /> PERIMETER OF AREA 4 4 PLAN OR SPECIFICATIONS <br /> =III-III-III-I I III-III=- I -III III III-I I IN 2" HIGH BLOCK + <br /> PERIMETER DRIPLINE PIPE TO BE INSTALLED 2"-4" FROM -III-III-III 1=III=III=1 -III-I I- I=III= LETTERS =III-III- -III 5 STARBUCKS COFFEE <br /> PERIMETER OF AREA I�-I I I-I I I-I I _ 5 _I-III III _ 5 NOTES: 3. FLUSH VALVE =III III=III= <br /> SUB-SURFACE DRIPLINE: -III-III-III I I-III= 1= 6 -I I I-I I- I I-III= 6 LOCATE STAPLES ALONG TUBING AT (NETAFIM =III=I 6 COMPANY <br /> RAIN BIRD XF SERIES DRIPLINE (TYPICAL) I-I I I-I I I-I I III-III= I-I I I I I I I - ABOUT 5' O.C.AND AT ALL FITTINGS -I 114 III=III= 2401 UTAH AVENUE SOUTH <br /> POTABLE: XFS DRIPLINE TEES, ELLS, ETC.) CHANGES IN TL050MFV-1 OR _ <br /> I -III-I I I-I I I I I-I I I-III- -1 I I-I I- I I-III- ( APPROVED EQUAL) =III=I - - 7 SEATTLE, WASHINGTON 98134 <br /> NON-POTABLE: XFSP DRIPLINE _ _ _ _ -I _ _ DIRECTION OF TUBING. BURY TUBING <br /> I I-III-I I I-I I III-III- I-III III III-III' 4. 1/2"SCH 40 PVC - (206)318-1575 <br /> RAIN BIRD XF SERIES BLANK TUBING -III-1 11-1 I I I I-I I1-I1 -1 I 1-I I- I I-I I FE PER THE IRRIGATION PLAN/NOTES. 04 - - - <br /> 7- THREADED 8 <br /> } BARB X BARB INSERT TEE OR CROSS: -I I I-I I I-I I III-III- 1�III III III-1 I COUPLER _ THESE DRAWINGS AND SPECIFICATIONS ARE <br /> 1'IIII=I I I I I-III- III I- I I-IIII SECTION 5. NATIVE SOIL - - Q CONFIDENTIAL AND SHALL REMAIN THE SOLE <br /> o RAIN BIRD XFF-TEE OR ELEVATION -III-I I-I 11- -1 I I-III-III- 6. COMMON BRICK =III-I _ <br /> -' PROPERTY OF STARBUCKS CORPORATION, <br /> RAIN BIRD XFD-CROSS (TYPICAL) SUPPORTS2 -III III=III= <br /> co ( _ _ _ 10 WHICH IS THE OWNER OF THE COPYRIGHT IN <br /> N AR I REQUIRED) =III-I THIS WORK. THEY SHALL NOT BE <br /> I %2" AIR RELIEF VALVE: RAIN BIRD MODEL: ARV050 7. 1/2"SCH 80 PVC -III III-III- REPRODUCED (IN WHOLE OR IN PART), SHARED <br /> (LENGTH AS III-I _ _ _ _ _ _ I I-III I WITH THIRD PARTIES OR USED IN ANY MANNER <br /> U I SEE RAIN BIRD XFS DETAILS FOR AIR RELIEF INSTALLATION REQUIRED) -III-III-III-III-III-III-III-III-III-III- ON OTHER PROJECTS OR EXTENSIONS TO THIS <br /> o I PVC SUPPLY HEADER 8. LATERAL LINE <br /> �I I PVC DRIP MANIFOLD FROM RAIN BIRD CONTROL ZONE VALVE I D ISI PLI N E TUBING PIPING PER =III=I I I=I I I=I I I=I I I=III=I I I=I I I=I I I=III=I PROJECT WITHOUT THE PRIOR WRITTEN <br /> CONSENT OF STARBUCKS CORPORATION. <br /> IRRIGATIONTHESE DRAWINGS AND SPECIFICATIONS ARE <br /> CU KIT (SIZED TO MEET LATERAL FLOW DEMAND) LEGEND (PLAN 12, INTENDED TO EXPRESS DESIGN INTENT FORA <br /> :> - - - - - PVC SCH 40 RISER PIPE PVC SCH 40 RISER PIPE SIZE) SECTION/ELEVATION PROTOTYPICAL STARBUCKS STORE (WHICH IS <br /> 06 9. SCH 40 PVC TEE <br /> •U INSET A SxSxT WITH 1/2"r � � � � � � � � � � � � � � � SUBJECT TO CHANGE AT ANYTIME)AND DO <br /> NOTES: NOT REFLECT ACTUAL SITE CONDITIONS. <br /> v I <br /> THREADED OUTLET---_- _--- I NEITHER PARTY SHALL HAVE ANY OBLIGATION <br /> co 1 . DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING __ __ 10. FILL BASE WITH 1 NOR LIABILITY TO THE OTHER(EXCEPT STATED <br /> �I TO BE BASED ON SOIL TYPE PLANT MATERIALS AND 1 i 1 CUBIC FOOT OF ABOVE) UNTIL A WRITTEN AGREEMENT IS <br /> CHANGES IN ELEVATION. SEE RAIN BIRD XFS DRIPLINE 1 4-6' 1 PEA GRAVEL FULLY EXECUTED BY BOTH PARTIES. <br /> ti 1 1 3" IN SHRUB AREAS <br /> LO INSTALLATION GUIDE FOR SUGGESTED SPACINGS. DRIP MANIFOLD 5 <br /> X 2. LENGTH OF LONGEST DRIPLINE LATERAL SHOULD NOT PVC DRIP MANIFOLD FROM RAIN BIRD 1 BURIAL DEPTH i ARCHITECT OF RECORD <br /> 0° EXCEED RAINBIRD'S RECOMMENDED MAXIMUM LENGTH. CONTROL ZONE VALVE KIT (SIZED TO _ _ _ _ ____ _ 1 mcg architecture <br /> �I 3. AIR RELIEF VALVE TO BE INSTALLED AT HIGH POINT OF MEET LATERAL FLOW DEMAND) 1 INSET A 1 I-III-III-III-III -III-III III=III= G AUTOMATIC FLU5H VALVE o � <br /> M 1 =1 I I-III-III-III-I 111 III= I_- 2 1. FINISH GRADE OR FINISH01 <br /> AREA. 1 1 GRADE OF OF MULCH LAYER > o ` <br /> =III-III-III-III =III-16111-III= <br /> CID4. WHEN USING 17MM INSERT FITTINGS WITH DESIGN PVC SCH 40 TEE OR EL (TYPICAL) 1 1 111=111-111=III=1 1II=I1I= 1=III 3 IF PRESENT _ <br /> 'o PRESSURE OVER 50P51, IT IS RECOMMENDED THAT -1 I I=I I I=I I I-III =I I I=I I I I I I I= 2. NATIVE SOIL U) <br /> 04 4 3. POLY TUBING PER Sm <br /> 0o STAINLESS STEEL CLAMPS BE INSTALLED ON EACH FITTING. PVC SCH 40 RISER PIPE I I-1I I-I I1-I I I-1 11II=I I I I-1 IRRIGATION LEGEND 1. FINISH GRADE <br /> -lII-III-I 11-1 I I = I-I I I= 2. 7" ROUND PLASTIC 15635 Alton Parkway,Suite 100,Irvine,CA 92618 <br /> CV I I=I I I-I II-III- _ III- 4. OPERATION INDICATOR - - - - 1 P:949.553.1117 F:949.474.7056 <br /> _ (NETAFIM#10-F-01 OR VALVE BOX WITH _ _ _ _ _ _ <br /> L END FEED LAYOUT 11 I-I I I-I I I-I -1 I I- APPROVED EQUAL) SNAP-ON LID(RAIN -I I I-I I I- I=III=III=III= <br /> U -1I1-II1-I I I 1 111=1 I I--III- 5. 2"-3"ABOVE FINISH GRADE BIRD VB-7RNDBK OR III-III-I I 3, - - 2 LANDSCAPE <br /> c I I-I I I-I I I- F = I I-I I I-I I I- 6. DEPTH OF TUBING PER APPROVED EQUAL) =III=III =III=III=III= ARCHITECT STAMP �PNDSCgpF <br /> o PVC SUPPLY PIPE FROM RAIN BIRD CONTROL ZONE KIT (SIZED -III-III-III -III-III-III-I LEGEND AND/OR NOTES HEAT BRAND"AR"ON :III=III=I I 3 �0 5 w TRo q�� <br /> TO MEET LATERAL FLOW DEMAND) I I-I I I-I I I-I =III=I I I-I I I-I 11= LID IN 2" HIGH BLOCK _ _ <br /> N -II1=1I1=1II-I _ =III-III-1 LETTERS - =III-III III=III=III= No 2242 0 <br /> TOTAL LENGTH OF SELECTED DRIPLINE SHOULD NOT EXCEED i = _ _ NOTES: N =III-III-I 4 <br /> �-III-III-III -I - -I 1 I-I I 1 3. AIR RELEASE VALVE _ _ Ex,. 10/31/z0 m <br /> IL LENGTH SHOWN IN TABLE INSTALL ONE OPERATION -III-III III-III=III= <br /> p "1 1 I-III-III-1 III-III I-I I IE INDICATOR FOR EACH DRIP (NETAFIM TLAVRV OR + _ _ _ <br /> d PVC SCH 40 TEE OR EL (TYPICAL) -I I I-I I I-I I I -I I I-I I I I I I-I I APPROVED EQUAL -I I I-I I I= 5 <br /> SYSTEM ZONE. LOCATE ) <br /> BARB X MALE FITTI NG: 1=I I I-I I I-I I 1 I-I I I-I I I I= 4. 1/2"SCH 40 PVC -III III=III= 6 qTF <br /> U) RAIN BIRD XFF-MA FITTING (TYPICAL) I I -111-111 11-� OPERATION INDICATOR THREADED COUPLER :IIOP cA <br /> I=I _ <br /> TOWARDS FLUSH END OF _ <br /> C/) PERIMETER OF AREA =III-I I I-I 1 I I-I I I= -III= 5. NATIVE SOIL <br /> SYSTEM, BUT IN OF THE -III III=III= <br /> 70 =I 1 I=I I I -I I I= III=1 6. COMMON BRICK - - 7 <br /> � _� \ �- - - �- - - I - - - - DRIP ZONE VALVE LOCATION IF -III=I =- <br /> - - - - - - - - - - - - =III=1 11 - 1 I 1=I I POSSIBLE. SUPPORTS (2 - - _ <br /> I 1 =III-III _-III-III= REQUIRED) N $ CHARLES <br /> \ -III-�-III-1111-1 1 1=I 1 7. 1/2"SCH 80 PVC TROWBRIDGE <br /> L - J \ L - J I -1 j l SECTION/ELEVATION <br /> o INSET A I \ INSET A I I =1 II 1111;„III- NIPPLE(LENGTH AS - - 9 AND ASSOCIATES <br /> BARB X BARB INSERT TEE OR CROSS: REQUIRED) =III-I _ SANT ANA,CA.E AVENUE <br /> U I \ I I 05 <br /> 8. LATERAL LINE PIPING -III III=III= PHr(71)532-3663 27FAX(714)532-3667 <br /> ch I \ I I RAIN BI RD XFF-TEE OR -I I I-I 10 chas2.ctaC-gmaiLcom <br /> PER IRRIGATION <br /> _ LANDSCAPE ARCHITECTURELIC.#2242 <br /> RAIN BIRD XFD-CROSS (TYPICAL)\\ LEGEND (PLAN SIZE) -III III-III= <br /> 9. SCH 40 PVC TEE SxSxT <br /> a I \ I A 1 =III= _ _ _ _ _ _ II-III=1 <br /> N I \ %" AIR RELIEF VALVE: RAIN BIRD MODEL: ARV050 WITH 1/2"THREADED =111=1 I IEEE El I I-I I I-1. I I= w <br /> \ ► j 1 I j O P E I AT I O N INDICATOR 10. OUTLET LL BASE WITH 1 =III=III=III=III=III=III=III=III=III=III=I J � <br /> U) \ - PERIMETER DRIPLINE PIPE TO BE INSTALLED 12" O <br /> Z I I CUBIC FOOT OF PEA <br /> `- \ 2"-4" FROM PERIMETER OF AREA N <br /> U I \\ \ 3'RIN SHRUB AREAS PURPLE LADE NOTE: INSTALL AIR RELIEF L0I PVC SCH 40\ I SUB-SURFACE DRIPLINE: VALVES AT HIGHEST ELEVATIONS CQ W <br /> \ ( ) G / Q <br /> o � \ RISER PIPE RAIN BIRD XF SERIES DRIPLINETYPICAL <br /> \ I FLUSH POINT (TYPICAL) Q <br /> \\ I POTABLE: XFS DRIPLINE SEE RAI N BI RD DETAI L "XFS FLUSH POI NT" OR "XFS AIR RE LEASE VALVE 06 co CU U <br /> o I \ I NON-POTABLE: XFSP DRIPLINE FLUSH POINT WITH BALL VALVE'' H w LL Z <br /> �I I I \ I RAIN BIRD XF SERIES BLANK TUBING bi U 0Y <br /> a I AR I \ X21) 4" BARB X MALE FITTING: 0 O <br /> c0 I \ I RAIN BIRD XFF-MA FITTING (TYPICAL) z LL Q Q F_ <br /> 2 I I \ FLUSH POINT (TYPICAL) <br /> 06 i I \\ i SEE RAIN BIRD DETAIL "XFS FLUSH POINT" OR PVC SCH 40 TEE OR EL (TYPICAL) I NOTES: LU U Lu p O <br /> "XFS FLUSH POINT WITH BALL VALVE" 1 . DISTANCE BETWEEN LATERAL ROWS AND 0 Q 0 <br /> \ I PERIMETER OF AREA I I O O <br /> FP I \ FPI I EMITTER SPACING TO BE BASED ON SOIL TYPE, a a 0 <br /> \ PLANT MATERIALS AND CHANGES IN ELEVATION. <br /> I I _ _ _ _ _ _ I PERIMETER DRIPLINE PIPE TO BE INSTALLED <br /> o I SEE RAIN BIRD XFS DRIPLINE INSTALLATION <br /> JBARB X BARB INSERT TEE OR CROS PVC EXHAUST HEADER 2" - 4" FROM PERIMETER OF AREA GUIDE FOR SUGGESTED SPACINGS. STORE #: 5470 <br /> LO PVC EXHAUST HEADER RAIN BIRD XFF-TEE OR CONNECTION FROM SUPPLY MANIFOLD TO DRIPLINE <br /> X FLUSH POINT (TYPICAL) RAIN BIRD XFD-CROSS (TYPICAL) (TYPICAL)- SEE INSET A 1 I 2. LENGTH OF LONGEST DRIPLINE LATERAL PROJECT #: 03030-052 <br /> ca SHOULD NOT EXCEED RAINBIRD'S <br /> U) SEE RAIN BIRD DETAIL "XF FLUSH POINT" OR "XFS FLUSH PVC SUPPLY PIPE FROM RAIN BIRD ETCORE <br /> I I I RECOMMENDED MAXIMUM LENGTH. ISSUE ISSUE DATE: <br /> cHECKSET2-10-20 <br /> POINT WITH BALL VALVE CONTROL ZONE KIT <br /> ci I I 3. AIR RELIEF VALVE TO BE INSTALLED AT HIGH <br /> LO NOTES: (SIZED TO MEET LATERAL FLOW DEMAND) � , PROGRAM MANAGER: M.DREBIKA <br /> 00 PVC SUPPLY MANIFOLD I POINT OF AREA. STORE DESIGNER: M.DREBIKA <br /> 1 . DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING TO BE BASED ON SOIL TYPE, J I 4. WHEN USING 17MM INSERT FITTINGS WITH LEED®AP: N/A <br /> x PLANT MATERIALS AND CHANGES IN ELEVATION. SEE RAIN BIRD XFS DRIPLINE INSTALLATION INSET A I DESIGN PRESSURE OVER 501`51, IT IS CHECKED BY: A.FELDMAN <br /> m GUIDE FOR SUGGESTED SPACINGS. I RECOMMENDED THAT STAINLESS STEEL <br /> 07 2. LENGTH OF LONGEST DRIPLINE LATERAL SHOULD NOT EXCEED RAINBIRD'S RECOMMENDED MCG PROJECT#: 18531 <br /> ' SUB-SURFACE DRIPLINE: I I CLAMPS BE INSTALLED ON EACH FITTING. MCG PROD. MANAGER: C.LEE <br /> o MAXIMUM LENGTH. RAIN BIRD XF SERIES DRIPLINE (TYPICAL) <br /> 3. AIR RELIEF VALVE TO BE INSTALLED AT HIGH POINT OF AREA. POTABLE: XFS DRIPLINE I I MCG PROJ. SPECIALIST: SPARK <br /> 4. WHEN USING 17MM INSERT FITTINGS WITH DESIGN PRESSURE OVER 50P51, IT IS <br /> a <br /> RECOMMENDED THAT STAINLESS STEEL CLAMPS BE INSTALLED ON EACH FITTING. RAIN BIRD XF SERIES BLANK TUBING I Revision Schedule <br /> 00I I 1 1 Rev Date By Description <br /> PVC SCH 40 RISER PIPE 1/2 AIR RELIEF VALVE: RAIN BIRD <br /> 1 ___--_--- _ --- 1 MODEL ARV050 <br /> PVC DRIP MANIFOLD FROM RAIN BIRD CONTROL ZONE VALVE <br /> KIT (SIZED TO MEET LATERAL FLOW DEMAND) <br /> 4-011 BARB X FEMALE FITTING: 1 <br /> 1 1 PVC SUPPLY MANIFOLD <br /> DRIP MANIFOLD RAINBIRD XFD-TFA-075 FITTING 1 1 <br /> 1 1 <br /> 1 BURIAL DEPTH 1 3/4" PVC NIPPLE, LENGTH AS NECESSARY <br /> PERIMETER DRIPLINE PIPE TO BE INSTALLED <br /> Q 1 SHEET TITLE: <br /> LO 1 ' 2" - 4" FROM PERIMETER OF AREA PVC SCH 40 TEE OR EL (TYPICAL) 1 1 DRIP IRRIGATION DETAILS <br /> 1 1 <br /> PVC SCH 40 TEE OR EL (TYPICAL) 1 INSET A 1 PVC EXHAUST HEADER CONNECTION FROM SUPPLY MANIFOLD 1 <br /> 1 1 TO DRIPLINE (TYPICAL)- SEE INSET A <br /> � SCALE: AS SHOWN <br /> 1 <br /> C14 PVC SCH 40 RISER PIPE SHEET NUMBER: <br /> N <br /> M IRREGULAR SHAPED LAYOUT K CENTER FEED LAYOUT LI-3 <br /> co <br />
The URL can be used to link to this page