CODE REQUIREMENTS (CBC) ACCESSIBILITY NOTES ACCESSIBILITY NOTES (CONT.)
<br /> ACCESSIBLE ROUTES FLOOR OR GROUND SPACES (CONT.) DOORS AND DOORWAYS (CONT.)
<br /> 11B-206.2.1 SITE ARRIVAL POINTS. AT LEAST ONE ACCESSIBLE ROUTE SHALL BE 11B-306.2.2 MAXIMUM DEPTH. TOE CLEARANCE SHALL EXTEND 25 INCHES (635 MM) .�►
<br /> �O �O PROVIDED WITHIN THE SITE FROM ACCESSIBLE PARKING SPACES AND MAXIMUM UNDER AN ELEMENT. TYPE OF USE MINIMUM MANEUVERING CLEARANCE
<br /> �C �C ACCESSIBLE PASSENGER LOADING ZONES; PUBLIC STREETS AND SIDEWALKS;
<br /> J J AND PUBLIC TRANSPORTATION STOPS TO THE ACCESSIBLE BUILDING OR FACILITY 11B-306.2.3 MINIMUM REQUIRED DEPTH. WHERE TOE CLEARANCE IS REQUIRED AT PARALLEL TO
<br /> ENTRANCE THEY SERVE. WHERE MORE THAN ONE ROUTE IS PROVIDED, ALL AN ELEMENT AS PART OF A CLEAR FLOOR SPACE, THE TOE CLEARANCE SHALL APPROACH DOOR OR GATE SIDE DIRECTION PERPENDICULAR TO DOORWAY(BEYOND DOORWAY LATCH SIDE UNLESS
<br /> \AO ROUTES MUST BE ACCESSIBLE. EXTEND 17 INCHES (432 MM) MINIMUM UNDER THE ELEMENT. NOTED)
<br /> ��w 11B-206.2.2 WITHIN A SITE.AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT 11B-306.2.4 ADDITIONAL CLEARANCE. SPACE EXTENDING GREATER THAN 6 FROM FRONT PULL 60 INCHES (1524 MM) 1B INCHES(457 MM)
<br /> `O `O ACCESSIBLE BUILDINGS, ACCESSIBLE FACILITIES, ACCESSIBLE ELEMENTS, AND INCHES (152 MM) BEYOND THE AVAILABLE KNEE CLEARANCE AT 9 INCHES (229 MM) FROM FRONT PUSH 48 INCHES (1219 MM) ( �D INCHES 0 MN)l
<br /> ©2011 STARBUCKS COFFEE
<br /> ACCESSIBLE SPACES THAT ARE ON THE SAME SITE. ABOVE THE FINISH FLOOR OR GROUND SHALL NOT BE CONSIDERED TOE FROF:1 HINGE SIDE PULL 60 INCHES (1524 MIA) 36 INCHES(914 MM)M)CLEARANCE. 44 INCHES(1115
<br /> 11B-206.2.4 SPACES AND ELEMENTS.AT LEAST ONE ACCESSIBLE ROUTE SHALL FROVA HINGE SIDE PUSH 22 INCHES(559 NIM)o STARBUCKS COFFEE
<br /> P� CONNECT ACCESSIBLE BUILDING OR FACILITY ENTRANCES WITH ALL ACCESSIBLE 11B-306.2.5 WIDTH. TOE CLEARANCE SHALL BE 30 INCHES (762 MM)WIDE MINIMUM. AJNP
<br /> SPACES AND ELEMENTS WITHIN THE BUILDING OR FACILITY, INCLUDING FROM LATCH SIDE PULL 60 INCHES (1524 MM) 24 INCHES(610 MM) COMPANY
<br /> MEZZANINES, WHICH ARE OTHERWISE CONNECTED BY A CIRCULATION PATH 11B-306.3 KNEE CLEARANCE. FROM LATCH SIDE PUSH 44 INCHES(1115 24 INCHES(610 MM)
<br /> UNLESS EXEMPTED BY SECTION IIB-206.2.3 EXCEPTIONS 1 THROUGH 7. Af1h4" 2401 UTAH AVENUE SOUTH
<br /> 116-306.3.1 GENERAL. SPACE UNDER AN ELEMENT BETWEEN 9 INCHES (229 MM) ADD 12 INCHES(3c6 1-1,1) IF CLOSER AND LATCH ARE PROVIDED. SEATTLE, WASHINGTON 98134
<br /> 11B-206.2.5 RESTAURANTS, CAFETERIAS, BANQUET FACILITIES AND BARS. IN AND 27 INCHES (686 MM)ABOVE THE FINISH FLOOR OR GROUND SHALL BE ADD 4 INCHES(�02 h.; IF CLOSER AND LATCH ARE PROVIDED. 206 318-1575
<br /> RESTAURANTS, CAFETERIAS, BANQUET FACILITIES, BARS, AND SIMILAR CONSIDERED KNEE CLEARANCE AND SHALL COMPLY WITH SECTION IIB-306.3. BEYOND HINGE 51DE.
<br /> ADD 4!FICHES IF CLOSER IS PROVIDED.
<br /> ADD 61NCNES(152,
<br /> FACILITIES, AN ACCESSIBLE ROUTE SHALL BE PROVIDED TO ALL FUNCTIONAL (152 ifo)ATEJCTERIOF2 SIDE O✓=EXTERIOR DOOF25. THESE DRAWINGS AND SPECIFICATIONS ARE
<br /> '�.v^r�r,�
<br /> AREAS, INCLUDING RAISED OR SUNKEN AREAS, AND OUTDOOR AREAS. 11B-306.3.2 MAXIMUM DEPTH. KNEE CLEARANCE SHALL EXTEND 25 INCHES (635 CONFIDENTIAL AND SHALL REMAIN THE SOLE
<br /> MM) MAXIMUM UNDER AN ELEMENT AT 9 INCHES (229 MM)ABOVE THE FINISH PROPERTY OF STARBUCKS CORPORATION, WHICH IS
<br /> _ 11B-206.2.8 EMPLOYEE WORK AREAS. COMMON USE CIRCULATION PATHS WITHIN FLOOR OR GROUND. THE OWNER OF THE COPYRIGHT IN THIS WORK.
<br /> EMPLOYEE WORK AREAS SHALL COMPLY WITH SECTION IIB-402. 11B-404.2.4 MANEUVERING CLEARANCES. MINIMUM MANEUVERING CLEARANCES THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN
<br /> p UNDER
<br /> AN AT DOORS AND GATES SHALL COMPLY WITH SECTION IIB-404.2.4. MANEUVERING PART), SHARED WITH THIRD PARTIES OR USED IN AN MINIMUM REQUIRED DEPTH. WHERE KNEE CLEARANCE IS REQUIRED CLEARANCES SHALL EXTEND THE FULL WIDTH OF THE DOORWAY AND THE MANNER ON OTHER PROJECTS OR EXTENSIONS TO
<br /> 0 116-402.2 COMPONENTS. ACCESSIBLE ROUTES SHALL CONSIST OF ONE OR MORE UNDER AN ELEMENT AS PART OF A CLEAR FLOOR SPACE, THE KNEE CLEARANCE LATCH SIDE OR HINGE SIDE CLEARANCE. THIS PROJECT WITHOUT THE PRIOR WRITTEN
<br /> REQUIRED L
<br /> O OF THE FOLLOWING COMPONENTS: WALKING SURFACES WITH A RUNNING SLOPE SHALL BE 11 INCHES (279 MM) DEEP MINIMUM AT 9 INCHES (229 MM)ABOVE THE REQUIRED
<br /> L SWINGING DOORS AND GATES. SWINGING DOORS AND GATES CONSENT OF STARBUCKS CORPORATION. THESE
<br /> I NOT STEEPER THAN 1:20, DOORWAYS, RAMPS, CURB RAMPS EXCLUDING THE FINISH FLOOR OR GROUND, AND 8 INCHES (203 MM) DEEP MINIMUM AT 27 INCHES 11B-40EQ SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE 118-404.2.4.1. DRAWINGS AND SPECIFICATIONS ARE INTENDED TO
<br /> NOTE: FLARED SIDES, ELEVATORS, AND PLATFORM LIFTS. ALL COMPONENTS OF AN 686 MM .
<br /> Q EQ 9 : ( )ABOVE THE FINISH FLOOR OR GROUNDEXPRESS DESIGN INTENT FOR A PROTOTYPICAL
<br /> � ACCESSIBLE ROUTE SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE
<br /> DOOR-MOUNTED RESTROOM DIVISION 4. 116-306.3.4 CLEARANCE REDUCTION. BETWEEN 9 INCHES (229 MM)AND 27 INCHES 11B-404.2.7 DOOR AND GATE HARDWARE. HANDLES, PULLS, LATCHES, LOCKS, AT ANYTIME)AND DO NOT REFLECT ACTUAL SITE
<br /> SIGNAGE TO COMPLY WITH AND OTHER OPERABLE PARTS ON DOORS AND GATES SHALL COMPLY WITH
<br /> 06 (686 MM)ABOVE THE FINISH FLOOR OR GROUND, THE KNEE CLEARANCE SHALL BE
<br /> SECTION CONDITIONS. NEITHER PARTY SHALL HAVE ANY
<br /> ` 9.4. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34 INCHES L 18 REQUIREMENTS.
<br /> CALIFORNIA TITLE 24 A.D.A. PERMITTED TO REDUCE AT A RATE OF 1 INCH (25 MM) IN DEPTH FOR EACH 6 FLOOR OR GROUND SPACES INCHES (152 MM) IN HEIGHT. (864 MM) MINIMUM
<br /> OBLIGATION NOR LIABILITY TO THE OTHER(EXCEPT
<br /> UM AND 44 INCHES (1118 MM) MAXIMUM ABOVE THE FINISH FLOOR STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS
<br /> a -000 OR GROUND. WHERE SLIDING DOORS ARE IN THE FULLY OPEN POSITION, FULLY EXECUTED BY BOTH PARTIES.
<br /> GC TO VERIFY COMPLIANCE 116-302 FLOOR OR GROUND SURFACES 11B-306.3.5 WIDTH. KNEE CLEARANCE SHALL BE 30 INCHES (762 MM)WIDE OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES.
<br /> I Q
<br /> O cG AND PROVIDE ADDITIONAL 116-302.1 GENERAL. FLOOR AND GROUND SURFACES SHALL BE STABLE, FIRM, AND MINIMUM. 11B-404.2.10 DOOR AND GATE SURFACES. SWINGING DOOR AND GATE SURFACES
<br /> - `�v SIGNAGE AS NECESSARY. SLIP RESISTANT AND SHALL COMPLY WITH SECTION 11B-302. WITHIN 10 INCHES (254 MM) OF THE FINISH FLOOR OR GROUND MEASURED ARCHITECT OF RECORD
<br /> ' O� REACH RANGES VERTICALLY SHALL HAVE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING
<br /> m "N E 11B-303 CHANGES IN LEVEL THE FULL WIDTH OF THE DOOR OR GATE. PARTS CREATING HORIZONTAL OR o •
<br /> 11B-308 REACH RANGES VERTICAL JOINTS IN THESE SURFACES SHALL BE WITHIN 1/16 INCH (1.6 MM) OF
<br /> �I UNISEX SIGNAGE 11B-303.1 GENERAL.WHERE CHANGES IN LEVEL ARE PERMITTED IN FLOOR OR THE SAME PLANE AS THE OTHER AND BE FREE OF SHARP OR ABRASIVE EDGES. U
<br /> �P
<br /> SHOWN, GROUND SURFACES, THEY SHALL COMPLY WITH SECTION I IB-303. 11B-308.1.1 ELECTRICAL SWITCHES. CONTROLS AND SWITCHES INTENDED TO BE CAVITIES CREATED BY ADDED KICK PLATES SHALL BE CAPPED. N
<br /> 0U0 O DESIGNATED SIGNAGE USED BY THE OCCUPANT OF A ROOM OR AREA TO CONTROL LIGHTING AND
<br /> FOR MEN'S&WOMEN'S 11B-303.2 VERTICAL. CHANGES IN LEVEL OF % INCH (6.4 MM) HIGH MAXIMUM SHALL RECEPTACLE OUTLETS, APPLIANCES OR COOLING, HEATING AND VENTILATING
<br /> BE PERMITTED TO BE VERTICAL AND WITHOUT EDGE TREATMENT. EQUIPMENT, SHALL COMPLY WITH SECTION 11 B-308 EXCEPT THE LOW REACH RAMPS m c g a r c h i t e c u r e
<br /> N ��� - RESTROOMS USED
<br /> N `o WHEN SHALL BE MEASURED TO THE BOTTOM OF THE OUTLET BOX AND THE HIGH REACH 15635 Alton Parkway, Suite 100, Irvine, CA 92618 11B-303.3 BEVELED. CHANGES IN LEVEL BETWEEN 1/4 INCH (6.4 MM) HIGH MINIMUM SHALL BE MEASURED TO THE TOP OF THE OUTLET BOX. 11B-405.2 SLOPE. RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER P:949.553.1117 F:949.474.7056
<br /> N APPLICABLE. AND /2 INCH (12.7 MM) HIGH MAXIMUM SHALL BE BEVELED WITH A SLOPE NOT THAN 1:12.
<br /> STEEPER THAN 1:2. 11B-308.1.2 ELECTRICAL RECEPTACLE OUTLETS. ELECTRICAL RECEPTACLE
<br /> U� � OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS AND COMMUNICATION 11B-405.4 FLOOR OR GROUND SURFACES. FLOOR OR GROUND SURFACES OF ARCHITECT STAMP
<br /> 0 11B-304 TURNING SPACE SYSTEM RECEPTACLES SHALL COMPLY WITH SECTION 11B-308 EXCEPT THE LOW RAMP RUNS SHALL COMPLY WITH SECTION 11B-302. CHANGES IN LEVEL OTHER gEQ A c
<br /> o REACH SHALL BE MEASURED TO THE BOTTOM OF THE OUTLET BOX AND THE HIGH THAN THE RUNNING SLOPE AND CROSS SLOPE ARE NOT PERMITTED ON RAMP G�G�P�,EW1N 'S'i�
<br /> rn 11B-304.3 SIZE. TURNING SPACE SHALL COMPLY WITH SECTION 11B-304.3.1 OR REACH SHALL BE MEASURED TO THE TOP OF THE OUTLET BOX. RUNS. FA
<br /> N 11B-304.3.2. -�
<br /> 11B-308.2 FORWARD REACH. 11B-405.5 CLEAR WIDTH. THE CLEAR WIDTH OF A RAMP RUN SHALL BE 48 INCHES - 1839
<br /> RCULAR
<br /> E.THE
<br /> ILL
<br /> RR DOOR SIGNAGE INCHES (15241 MM) DIAMETER MINIMUM TURNING
<br /> SPACE SHALL BE PERMITTED TO 11B-308.2.1 UNOBSTRUCTED. WHERE A FORWARD REACH IS UNOBSTRUCTED, THE 11B-405.6)RISE. HE RISE FOR ANY RAMP RUN SHALL BE 30 INCHES (762 MM) 9/ 1 tiP
<br /> � 15 INCLUDE KNEE AND TOE CLEARANCE COMPLYING WITH SECTION IIB-306. HIGH FORWARD REACH SHALL BE 48 INCHES (1219 MM) MAXIMUM AND THE LOW MAXIMUM. ��
<br /> 4 Scale: 1/2"=1'=0" ELEVATION FORWARD REACH SHALL BE 15 INCHES (381 MM) MINIMUM ABOVE THE FINISH DF CA1_1 O-
<br /> N 11B-304.3.2 T-SHAPED SPACE. THE TURNING SPACE SHALL BE A T-SHAPED SPACE FLOOR OR GROUND. 11B-405.7 LANDINGS. RAMPS SHALL HAVE LANDINGS AT THE TOP AND THE
<br /> 0
<br /> U)
<br /> _0 WITHIN A 60 INCH (1524 MM) SQUARE MINIMUM WITH ARMS AND BASE 36 INCHES BOTTOM OF EACH RAMP RUN. LANDINGS SHALL COMPLY WITH SECTION IIB-405.7.
<br /> N 914 MM WIDE MINIMUM. EACH ARM OF THE T SHALL BE CLEAR OF OBSTRUCTIONS 11B-308.2.2 OBSTRUCTED HIGH REACH.WHERE A HIGH FORWARD REACH IS OVER
<br /> WOMEN MEN UNISEX WALL MOUNTED SIGNAGE TO BE LOCATED ON ( ) ( )
<br /> c� 12 INCHES 305 MM MINIMUM IN EACH DIRECTION AND THE BASE SHALL BE CLEAR AN OBSTRUCTION, THE CLEAR FLOOR SPACE SHALL EXTEND BENEATH THE
<br /> LATCH SIDE OF DOOR CLEAR OF DOOR-SWING. OF OBSTRUCTIONS 24 INCHES (610 MM) MINIMUM. THE SPACE SHALL BE PERMITTED ELEMENT FOR A DISTANCE NOT LESS THAN THE REQUIRED REACH DEPTH OVER CURB RAMPS
<br /> MOUNT AT 60" MAX TO BASELINE OF THE HIGHEST TO INCLUDE KNEE AND TOE CLEARANCE COMPLYING WITH SECTION I IB-306 ONLY THE OBSTRUCTION. THE HIGH FORWARD REACH SHALL BE 48 INCHES (1219 MM)
<br /> LINE OF RAISED CHARACTERS PER 11 B-703. AT THE END OF EITHER THE BASE OR ONE ARM. MAXIMUM WHERE THE REACH DEPTH IS 20 INCHES (508 MM) MAXIMUM. WHERE 11B-406.2 PERPENDICULAR CURB RAMPS. PERPENDICULAR CURB RAMPS SHALL
<br /> U THE REACH DEPTH EXCEEDS 20 INCHES (508 MM), THE HIGH FORWARD REACH COMPLY WITH SECTIONS 11B-406.2 AND 11B-406.5.
<br /> 11B-305.7 MANEUVERING CLEARANCE.WHERE A CLEAR FLOOR OR GROUND SHALL BE 44 INCHES (1118 MM) MAXIMUM AND THE REACH DEPTH SHALL BE 25
<br /> LETTERING RAISED 1/32" _ LL GENDER SPACE IS LOCATED IN AN ALCOVE OR OTHERWISE CONFINED ON ALL OR PART OF INCHES (635 MM) MAXIMUM. 11B-406.2.1 SLOPE. RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER
<br /> Q THREE SIDES, ADDITIONAL MANEUVERING CLEARANCE SHALL BE PROVIDED IN THAN 1:12.
<br /> ACCORDANCE WITH SECTIONS IIB-305.7.1 AND IIB-305.7.2. 11B-308.3 SIDE REACH.
<br /> O HEIGHT OF LETTERING 5/8" RESTROOM 11B-406.2.2 SIDES OF CURB RAMPS. WHERE PROVIDED, CURB RAMP FLARES
<br /> MIN. TO 2" MAX. 11B-305.7.1 FORWARD APPROACH. ALCOVES SHALL BE 36 INCHES (914 MM)WIDE 11B-308.3.1 UNOBSTRUCTED. WHERE A CLEAR FLOOR OR GROUND SPACE SHALL NOT BE STEEPER THAN 1:10. J
<br /> CO 12" 12' 12" ::•. 1:1.:.:•1•r.::.1.%11
<br /> z MINIMUM WHERE THE DEPTH EXCEEDS 24 INCHES (610 MM). ALLOWS A PARALLEL APPROACH TO AN ELEMENT AND THE SIDE REACH IS CV
<br /> UNOBSTRUCTED, THE HIGH SIDE REACH SHALL BE 48 INCHES (1219 MM) MAXIMUM 11B-406.3 PARALLEL CURB RAMPS. PARALLEL CURB RAMPS SHALL COMPLY WITH ' Lo
<br /> v SYMBOL DESCRIPTIONS CORRESPONDING GRADE II BRAILLE. PER 11B-305.7.2 PARALLEL APPROACH.ALCOVES SHALL BE 60 INCHES (1524 MM)WIDE AND THE LOW SIDE REACH SHALL BE 15 INCHES (381 MM) MINIMUM ABOVE THE SECTIONS 11B-406.3 AND 11B-406.5. L1.1
<br /> �I
<br /> MINIMUM WHERE THE DEPTH EXCEEDS 15 INCHES (381 MM). FINISH FLOOR OR GROUND.
<br /> CBC SECT. 11B-703.3.2 BRAILLE SHALL BE
<br /> 0 WOMEN'S SIGNAGE: 12" DIAMETER CIRCLE, 1/4"THICK. FLUSH LEFT OR CENTERED AND PLACED A Q 11B-406.3.1 SLOPE. THE RUNNING SLOPE OF THE CURB RAMP SEGMENTS SHALL Q Q
<br /> �
<br /> 11B-305 CLEAR FLOOR OR GROUND SPACE 11B-308.3.2 OBSTRUCTED HIGH REACH. WHERE A CLEAR FLOOR OR GROUND BE IN-LINE WITH THE DIRECTION OF SIDEWALK TRAVEL. RAMP RUNS SHALL HAVE MIN. OF 3/8" INCH AND MAXIMUM OF 1/2 _ ,�x (n
<br /> U o z SPACE ALLOWS A PARALLEL APPROACH TO AN ELEMENT AND THE HIGH SIDE A RUNNING SLOPE NOT STEEPER THAN 1:12. W U) U
<br /> MEN'S SIGNAGE: EQUILATERAL TRIANGLE, 1/4"THICK WITH EDGES 12" INCH BELOW RAISED CHARACTERS OR (0
<br /> LONG &A VERTEX POINTING UPWARD. SYMBOLS 11B-305.2 FLOOR OR GROUND SURFACES. FLOOR OR GROUND SURFACES OF A REACH IS OVER AN OBSTRUCTION, THE HEIGHT OF THE OBSTRUCTION SHALL BE LLU Z
<br /> U)I v CLEAR FLOOR OR GROUND SPACE SHALL COMPLY WITH SECTION 11B-302. 34 INCHES (864 MM) MAXIMUM AND THE DEPTH OF THE OBSTRUCTION SHALL BE 24 116-406.3.2 TURNING SPACE.A TURNING SPACE 48 INCHES (1219 MM) MINIMUM BY U
<br /> UNISEX SIGNAGE: 12" DIAMETER CIRCLE, 1/4"THICK TRIANGLE CHANGES IN LEVEL ARE NOT PERMITTED. INCHES (610 MM) MAXIMUM. THE HIGH SIDE REACH SHALL BE 48 INCHES (1219 MM) 48 INCHES (1219 MM) MINIMUM SHALL BE PROVIDED AT THE BOTTOM OF THE CURB Q 0p U O
<br /> Q SUPERIMPOSED WITHIN CIRCLE. MAXIMUM FOR A REACH DEPTH OF 10 INCHES (254 MM) MAXIMUM. WHERE THE RAMP. THE SLOPE OF THE TURNING SPACE IN ALL DIRECTIONS SHALL BE 1:48 Z Q Q
<br /> mFINISHED FLOOR EXCEPTION: SLOPES NOT STEEPER THAN 1:48 SHALL BE PERMITTED. REACH DEPTH EXCEEDS 10 INCHES (254 MM), THE HIGH SIDE REACH SHALL BE 46 MAXIMUM. H H
<br /> ALL SIGNAGE: SIGNS ARE TO BE CENTERED ON THE DOOR 60" FROM THE INCHES (1168 MM) MAXIMUM FOR A REACH DEPTH OF 24 INCHES (610 MM) U 0 U U
<br /> 06 FLOOR. THE COLOR AND CONTRAST OF THE SIGN DISTINCTIVELY 11B-305.3 SIZE. THE CLEAR FLOOR OR GROUND SPACE SHALL BE 30 INCHES (762 MAXIMUM. 116-406.5 COMMON REQUIREMENTS. CURB RAMPS AND BLENDED TRANSITIONS W W O
<br /> U CONTRASTS WITH THE COLOR AND CONTRAST OF THE DOOR. MM) MINIMUM BY 48 INCHES (1219 MM) MINIMUM. SHALL COMPLY WITH SECTION 11 B-406.5. 0 Q O
<br /> 11B-309 OPERABLE PARTS a ^ a 00
<br /> d 11B-305.4 KNEE AND TOE CLEARANCE. UNLESS OTHERWISE SPECIFIED, CLEAR L.L
<br /> OI RESTROOM DOOR SIGNAGE ACCESSIBLE ID WALL SYMBOLS CLOEAORAONCE COMPLYING WITH SECTION PERMITTED
<br /> TO INCLUDE KNEE AND TOE 116-309.1 GENERAL. OPERABLE PARTS SHALL COMPLY WITH SECTION 118-309.
<br /> � 18 14 „ _ ,- „ 116-309.2 CLEAR FLOOR SPACE. A CLEAR FLOOR OR GROUND SPACE COMPLYING STORE #: 5470
<br /> U-) Scale:N.T.S. scae: 1 1/2 - 1 0
<br /> X 11B-305.5 POSITION. UNLESS OTHERWISE SPECIFIED, CLEAR FLOOR OR GROUND WITH SECTION IIB-305 SHALL BE PROVIDED. PROJECT #: 03030-052
<br /> m SPACE SHALL BE POSITIONED FOR EITHER FORWARD OR PARALLEL APPROACH TO OO OO OO OO
<br /> (n AN ELEMENT. 11B-309.3 HEIGHT. OPERABLE PARTS SHALL BE PLACED WITHIN ONE OR MORE OF CASEWORK CONCEPT: CORE
<br /> I THE REACH RANGES SPECIFIED IN SECTION 11B-308. ISSUE DATE: CHECKSET 2-10-20
<br /> CBC SECT 1008.1.1 -DOOR SIZE
<br /> c 11B-305.6 APPROACH. ONE FULL UNOBSTRUCTED SIDE OF THE CLEAR FLOOR OR O O O P` PROGRAM MANAGER: M.DREBIKA
<br /> *T-0"DOOR WIDTH GROUND SPACE SHALL ADJOIN AN ACCESSIBLE ROUTE OR ADJOIN ANOTHER 11B-309.4 OPERATION. OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND 00 -
<br /> *6'-8"HEIGHTCLEAR FLOOR OR GROUND SPACE. AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE STORE DESIGNER: M.DREBIKA
<br /> x *32"CLEAR WIDTH WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 LEED(:DAP: N/A
<br /> D 0 L n 11B-305.7 MANEUVERING CLEARANCE.WHERE A CLEAR FLOOR OR GROUND POUNDS (22.2 N) MAXIMUM. O OO OO OO CHECKED BY: A.FELDMAN
<br /> LO
<br /> m CBC SECT 11B-404.2.9-DOOR OPENING FORCE SPACE IS LOCATED IN AN ALCOVE OR OTHERWISE CONFINED ON ALL OR PART OF
<br /> c14 MCG PROJECT#: 18531
<br /> p
<br /> *TYPE OF HARDWARE:PUSH/PULL THREE SIDES, ADDITIONAL MANEUVERING CLEARANCE SHALL BE PROVIDED IN DOORS AND DOORWAYS O O O OO MCG PROJ. MANAGER: C.LEE
<br /> *MAX.EFFORT OFR EXT.DOORS=5 LBS ACCORDANCE WITH SECTIONS 11 B-305.7.1 AND I IB-305.7.2.
<br /> *MAX EFFORT FOR INT DOORS=5LBS 11B-404.2 MANUAL DOORS DOORWAYS AND MANUAL GATES. MANUAL DOORS MCG PROJ. SPECIALIST: SPARK
<br /> U INTERIOR / *REQUIRED FIRE DOORS,MAX.EFFORT-15 LBS. 11B-305.7.1 FORWARD APPROACH. ALCOVES SHALL BE 36 INCHES (914 MM)WIDE AND DOORWAYS AND MANUAL GATES INTENDED FOR USER PASSAGE SHALL 0.45"AT TOP TYPICAL PLAN
<br /> / CBC SECT 11336.2.6 SMOOTH SURFACE 12" DIA 1'-0" 1'-0" MINIMUM WHERE THE DEPTH EXCEEDS 24 INCHES (610 MM). 2.35"
<br /> COMPLY WITH SECTION IIB-404.2. 90"AT BASE Revision Schedule
<br /> d
<br /> op * 10"KICKPLATE OR SMOOTH FULL UNISEX SIGNAGE IS FOR ALL 11B-305.7.2 PARALLEL APPROACH.ALCOVES SHALL BE 60 INCHES (1524 MM)WIDE 116-404.2.2 DOUBLE-LEAF DOORS AND GATES.AT LEAST ONE OF THE ACTIVE Rev Date B Description
<br /> WIDTH OF DOOR SINGLE ACCOMMODATION MINIMUM WHERE THE DEPTH EXCEEDS 15 INCHES (381 MM). LEAVES OF DOORWAYS WITH TWO LEAVES SHALL COMPLY WITH SECTIONS Y
<br /> N LU *4"FOR SOLD GLASS DOORS RESTROOMS GROUT BED.
<br /> 118-404.2.3 AND 118-404.2.4.
<br /> 11B-306 KNEE AND TOE CLEARANCE ~ JOINT COLOR TO MATCH TILES.
<br /> LU
<br /> SANITARY FACILITIES
<br /> Q CBC SECT 1113-404.2.10 11B-404.2.3 CLEAR WIDTH. DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF o
<br /> THRESHOLDS SECTION 2-1711. (TITLE 24 STATE BUILDING CODE) 116-306.1 GENERAL.WHERE SPACE BENEATH AN ELEMENT IS INCLUDED AS PART 32 INCHES (813 MM) MINIMUM. CLEAR OPENINGS OF DOORWAYS WITH SWINGING N RECESS CONC. PER MFR.
<br /> M *1/2"MAX.THRESHOLD 3-I1DENTIFICATION SYMBOLS: OF CLEAR FLOOR OR GROUND SPACE OR TURNING SPACE, THE SPACE SHALL DOORS SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE RECOMMENDATIONS. TYPICAL SECTION A
<br /> p ON DOORWAYS LEADING TO MEN'S SANITARY FACILITIES AN EQUILATERAL COMPLY WITH SECTION IIB-306.ADDITIONAL SPACE SHALL NOT BE PROHIBITED STOP, WITH THE DOOR OPEN 90 DEGREES. OPENINGS MORE THAN 24 INCHES
<br /> d Q *114"
<br /> T.MAX.SLOPE TRIANGLE 1/4"THICK WITH EDGES 12" LONG AND A VERTEX POINTING BENEATH AN ELEMENT BUT SHALL NOT BE CONSIDERED AS PART OF THE CLEAR (610 MM) DEEP SHALL PROVIDE A CLEAR OPENING OF 36 INCHES (914 MM) NOTE: SHEET TITLE:
<br /> UPWARD. FLOOR OR GROUND SPACE OR TURNING SPACE. MINIMUM. THERE SHALL BE NO PROJECTIONS INTO THE REQUIRED CLEAR 1. DETECTABLE WARNING SHALL BE OF CONTRASTING COLOR WITH ACCESSIBILITY NOTES
<br /> if O EXTERIOR ADJACENT
<br /> OPENING WIDTH LOWER THAN 34 INCHES (864 MM)ABOVE THE FINISH FLOOR
<br /> SYMBOLS SHALL BE MOUNTED ON THE DOOR AT A HEIGHT OF +60"AFF TO THE 11B-306.2 TOE CLEARANCE. OR GROUND. PROJECTIONS INTO THE CLEAR OPENING WIDTH BETWEEN 34 SURFACE: LIGHT-ON-DARK OR DARK-ON-LIGHT. MATERIAL SHALL BE
<br /> CENTERLINE OF SIGN, &THEIR COLOR AND CONTRAST SHALL BE DISTINCTLY INTEGRAL PART OF THE WALKING SURFACE.
<br /> SECTION @ENTRY DOOR DIFFERENT FROM THE COLOR &CONTRAST OF THE DOOR. 11B-306.2.1
<br /> GROUND ANDES INCHES (229 MM)ABOVE THE FINISH FLOOR OR E FINISHOUND SHALL OORSH
<br /> SPACE UNDER AN ELEMENT BETWEEN BOR INCHES MM)AND 80 INCHES (2032 MM)ABOVE THE FINISH FLOOR OR 2. TRUNCATED
<br /> DOMES
<br /> TO(076 E- "INTERLOCK SAN DIEGO"
<br /> 5566 OR APPROVED EQUAL. STONE, SCALE:AS SHOWN
<br /> O GROUND SHALL NOT EXCEED 4 INCHES (102 MM).
<br /> N ADA COMPIANCE DETAIL _ CCESSIBLE ID DOOR SYMBOLS CONSIDERED TOE CLEARANCE AND SHALL COMPLY WITH SECTION 118-306.2. TRUNCATED DOMES SHEET NUMBER:
<br /> - 1 Irle: 1 1/2" = 1'-0" ,1 scare: 6" = 1'-0" G004
<br /> Scale: N.T.S.
<br />
|