Laserfiche WebLink
S�NJOAQ�IN Environmental Health Department <br />COUNTY <br />Grectneis yro vs here. <br />APPLICATION FOR UNDERGROUND STORAGE TANK <br />RETROFIT OR PIPING REPAIR PERMIT <br />[ ] 1. Submit all information in triplicate. Answer all questions, leaving no blanks. One copy will be returned <br />to the applicant with comments. <br />[ ] 2. Include a detailed site map on a separate sheet of paper showing all work to be done. Include the <br />location of the tanks(s), piping, all tank -related appurtenances, streets, adjacent properties (north toward <br />the top of the page), nearby septic tanks, leachflelds, water wells, buildings, underground public utility <br />lines (including water, sanitary sewer and storm sewer), and distance of piping from tank to dispensers. <br />If underground utilities are not included on the site map, you must state in writing that USA Dig will be <br />contacted prior to excavation activities. <br />(] 3. Complete pages 3-6, "APPLICATION FOR UNDERGROUND STORAGE TANK RETROFIT OR <br />PIPING REPAIR PERMIT". NOTE: If sampling is required, sampling firm shall be an independent third <br />party, from the contractor performing the work. <br />[ ] 4. Complete page 7, "Authorization to Release". This form must be signed and dated by the <br />OWNER/OPERATOR of the facility. <br />[ ] 5. Submit a completed "Service Request" form and "Underground Storage Tank Program Fee <br />Worksheet". <br />[ ] 6. If performing any excavation activities, and the facility is located outside of the city limits, submit a <br />"Backfill Excavation Certificate" as required by the San Joaquin County Building Department. If a <br />"Backfill Excavation Certificate" is required by any incorporated areas (cities), submit to the <br />appropriate City Building Departments, pursuant to the Uniform Building Code STD 70-11. <br />[ ] 7. The maximum review time for Pian Review is 15 working days from receipt of the adequately <br />completed Man. If gross deficiencies are identified, an addendum will be required with a $152.00 per <br />hour fee and the review will begin on the date of resubmittal. <br />(� 8. Advance inspection notice of at least 48 hours is required by the <br />Environmental Health Department (EHD). <br />(] 9. Contractor to Provide: Combustible/Flammable gas detector (to verify the Lower Explosive Limit <br />(LEL) atmosphere and oxygen level), adequate number(s) and appropriate type(s) of fire extinguisher(s), <br />and barriers to secure the area as necessary to minimize traffic and pedestrian interference. It shall be <br />the project managers responsibility for compliance with all health & safety regulations and requirements, <br />including confined space requirements, which shall be strictly adhered to at all times during the course of <br />the underground storage tank (UST) activities. <br />[ ] 10. The EHD permit shall be on site during all UST permit -related activities. <br />[ ] 11. Any changes in this document shall be approved by the EHD prior to initiating work. All changes to <br />any work must be described in detail on pages 3 & 4 and be shown on the detailed site map. <br />1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-34.201 F 209 464-0138 1 www.sjcehd.com <br />