My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1340
>
2300 - Underground Storage Tank Program
>
PR0529124
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2021 10:46:49 AM
Creation date
10/5/2021 9:29:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0529124
PE
2351
FACILITY_ID
FA0019437
FACILITY_NAME
ARCO am/pm # 83230
STREET_NUMBER
1340
Direction
W
STREET_NAME
COLONY
STREET_TYPE
Rd
City
Ripon
Zip
95366
APN
261-590-110-000
CURRENT_STATUS
01
SITE_LOCATION
1340 W Colony Rd
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br />Monitoring System Certification Form <br />A separate Monitoring System Certification Form must be prepared for each control panel. <br />Make of Monitoring System <br />Model of Monitoring System <br />Software Version Installed <br />Control Panel <br />Control Panel <br />Veeder-Root <br />TLS -350 PLUSI <br />333.00 <br />Attach the post -certification reports if the monitoring system is capable of generating <br />either, xMonitoring System Set-up xAlarm History Report <br />Yes <br />iVo Y <br />NA <br />All monitoring equipment is operational per manufacturer's specifications? <br />x <br />❑ <br />Secondary containment systems arefree of damage, debris, or liquid? <br />x <br />❑ <br />; : ;_: <br />Are the audible and visual alarms operational? <br />x <br />❑ <br />All sensors have been: 1) visually inspected for wiring kinks, breaks andresidual buildup on <br />x <br />❑ <br />❑ <br />floats; and 2) tested for functionality and confirmed operational? <br />Are all sensors installed to detect a release at the earliest opportunity in the secondary <br />x <br />❑ <br />O <br />containment? <br />The monitoring system set-up was reviewed,and proper settings confirmed? <br />x <br />❑ <br />❑ <br />Was the monitoring control panel's backup battery visually inspected, functionally tested, <br />x <br />❑ <br />❑ <br />and confirmed operational? <br />Does the flow of fuel stop at the dispenser if a release is detected in the under -dispenser <br />x <br />❑ <br />containment? <br />Does the turbine automatically shut down if the piping secondary containment monitoring <br />x <br />❑ <br />❑ <br />system fails to operate or is electrically disconnected? <br />Does the turbine automatically shut down if the piping secondary containment monitoring <br />system detects a release?Which sensors initiate positive shut down? (Check all that <br />X <br />❑ <br />❑ <br />apply)xSump xUDC <br />If monitoring system alarms are relayed to a remote monitoring center, is all communication <br />O <br />❑ <br />x <br />equipment operational? <br />Describe all answers marked "No" or "Fail"and proposed remedy in Section 9. <br />List all monitoring equipment either replaced or repaired in Section 9 <br />Page 2 of 6 <br />