My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EIGHT MILE
>
2994
>
1600 - Food Program
>
PR0547204
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2021 12:14:02 PM
Creation date
10/7/2021 3:50:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0547204
PE
1625
FACILITY_ID
FA0026788
FACILITY_NAME
BURGER KING #27834
STREET_NUMBER
2994
Direction
W
STREET_NAME
EIGHT MILE
STREET_TYPE
RD
City
STOCKTON
Zip
95209
CURRENT_STATUS
01
SITE_LOCATION
2994 W EIGHT MILE RD
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL ROOFING NOTES : O KEYED NOTES : 2,_3„ SSDOWN AT PRIMAY <br /> CUPPEROTO CONNECT TO <br /> 1. ROOFING SUBCONTRACTOR TO COORDINATE LOCATION OF H.V.A.C. UNITS 1 1 -9 STORM SEWER CATCH BASIN. j <br /> AND ROOF TOP ACCESSORIES WITH STRUCTURAL, MECHANICAL AND 1. TWO-PLY MODIFIED BITUMEN MEMBRANE W/GLASS FIBER REINFORCEMNT. BOTTOM COORDINATE WITH CIVIL o <br /> ELECTRICAL DRAWINGS FOR PLACEMENT AND TAPERED RIGID INSULATION PLY SHALL BE UNSURFACED, TOP PLY SHALL HAVE WHITE MINERAL SURFACE. ENGINEERING DWGS. (TYPICAL) I <br /> Ln <br /> BOARD LAY-OUT AND SUBSEQUENT INSTALLATION IN ORDER TO AVOID 2. ROOF ACCESS LADDER, REFERENCE DETAIL, THIS SHEET. o <br /> 7 <br /> PONDING WATER CONDITIONS ATTRIBUTABLE TO BOARD LAY-OUT ISSUES. 3. PREFABRICATED METAL AWNING OR CANOPY. REFERENCE SHEET A-9. 7 4 7 <br /> 2. ROOF SYSTEMS SPECIFIED SHALL BE APPLIED ONLY BY MANUFACTURER 4. VENT THROUGH ROOF - PROVIDE PREFABRICATED DURO-LAST VENT FLASHING FOR O <br /> w <br /> APPROVED APPLICATOR IN ORDER TO MEET GUARANTEE REQUIREMENTS. ALL VENTS AND PIPE PENETRATIONS. REFERENCE DETAIL #6, THIS SHEET. Q <br /> 3. COORDINATE LOCATION OF MECHANICAL UNITS WITH STRUCTURAL AND 5. INSTALL MODIFIED BITUMEN SACRIFICE SHEET AS SPECIFIED AT KITCHEN EXHAUST. " pQ <br /> MECHANICAL DRAWINGS. 6. ROOF CRICKET WITH SLOPE TO MATCH ROOF, REFER TO DETAIL #3, THIS SHEET. 9 71 <br /> 4. HVAC CONDENSATE LINES TO TERMINATE AT ROOF DRAIN OR AS REQUIRED 7. PRIMARY AND OVERFLOW ROOF SCUPPERS - REFER TO DETAILS #4 AND #7 THIS 2 � 6 p <br /> BY LOCAL CODE. SHEET. cr <br /> 6 w <br /> 5. REFER TO STRUCTURAL AND M-E-P DRAWINGS FOR ADDITIONAL 8. ROOTTOP AIR CONDITIONING UNIT - REFER TO MECHANICAL PLANS. 1" PVC Q Z <br /> INFORMATION. 9. EXHAUST FAN - REFER TO MECHANICAL PLANS z o <br /> 6. ALL CURBS AND PIPE PENETRATIONS SHALL HAVE A MINIMUM OF 16" 10. ILLUMINATED PARAPET LIGHT BAND. I I ~ cn <br /> CLEAR FROM EACH OTHER FOR ROOF FLASHING PURPOSES. ALL 11. METAL COPING. SLOPE > <br /> EQUIPMENT SHALL HAVE A MINIMUM OF 16" CLEAR FROM ALL ADJACENT 12. PVC CONDENSATE DRAIN (SIZE AS SHOWN) WITH PIPE SUPPORTS EVERY 5'-0". cn 12 <br /> PARAPETS. ALL HVAC MOUNTED EQUIPMENT (DISCONNECT BOXES, GFCI, TERMINATE CONDENSATE DRAIN AT PRIMARY SCUPPER. REFER TO DETAIL #8, THIS 4-u p 3/4" PVC <br /> PIPE SUPPORTS) SHALL NOT BE CLOSER THAN 16" FROM EACH OTHER OR SHEET FOR ADDITIONAL INFORMATION. O / m °o <br /> CURB. NO UNISTRUT PIPE SUPPORTS SHALL BE USED AS VERTICAL 13. PROVIDE PITCH PAN WITH CONDUIT OVER OFFICE FOR SATELLITE DISH/ANTENNA. N <br /> MEMBERS FOR MOUNTING EQUIPMENT TO ROOF SURFACE. 14. EQUIPMENT STAND FOR WALK-IN BOX COOLER/FREEZER CONDENSERS AND ICE WATER HEATER41 <br /> 7. PONDING WATER IS DEFINED AS WATER THAT DOES NOT DRAIN OR MACHINE CONDENSER. REFER TO EQUIPMENT STAND DETAIL, THIS SHEET. VENT I I - cn w <br /> DISSIPATE FROM THE ROOF WITHIN 48 HOURS AFTER PRECIPITATION. 15. AREA TO BE RESERVED FOR SOLAR PER CEC 110.10 ^ ` 6 I I _0 O <br /> 14 L_�ll!3 m v <br /> 8. CONTRACTOR SHALL "SUGAR-IN" ALL ASPHALT. BLEED-OUT ON PLIES WITHnn rd nn nn I <br /> - - - ��_.�- J m <br /> ADDITIONAL GRANULES TO MATCH EXISTING COLORATION OF THE MINERAL Im <br /> SURFACE CAP SHEET. -^-0 ❑� N <br /> 9. ALL FLASHING CEMENTS, ASPHALTS, PRODUCTS AND ACCESSORIES SHALL BE GENERAL NOTES ■ i i j/4'_PVC _ \ \ 6 3/4" PVC 1�PVC Q <br /> APPROVED BY ROOFING MANUFACTURER WITH THE MANUFACTURES'S BRAND. m 013 6 ~ <br /> ALL ASPHALTS SHALL BE AMERICAN MANUFACTURED PRODUCTS. A. THE ROOF STRUCTURE SHALL NOT BE USED FOR STOCKPILING OF EQUIPMENT OR m R-M-4- \ N <br /> MATERIALS UNLESS APPROVED BY THE ARCHITECT, STRUCTURAL ENGINEER AND THE \ O3 <br /> JOIST MANUFACTURER. " \ e 1 m <br /> B. THE ROOFING SYSTEM SHALL BE AS PER DRAWINGS AND PER MANUFACTURERS w <br /> SPECIFICATIONS. 6 15 � Q <br /> 2 1,� A/C FRESH AIR Q o <br /> C. COORDINATE ROOF ELEVATIONS WITH STRUCTURAL DRAWINGS. REFER TO � EF-3 INTAKE TO BE WITHIN 110� <br /> MODIFIED BITUMEN FR CAP SHEET SPECIFICATION SHEET FOR ROOF RELATED ITEMS, INCLUDING GUARANTEES, CURBS, 4 0 <br /> FLASHING, ETC. 11 O 10'-0" OF ANY EXHAUST <br /> PER MFR. SPECIFICATIONS - MOPPED IN FANS AND STACKS 11 0 <br /> ASPHALT I a I 11 <br /> MODIFIED BITUMEN BASE SHEET PER MFR. <br /> SPECIFICATIONS - MOPPED IN ASPHALT ELASTOMERIC SEALANT THOROUGHLY CLEAN PENETRATION 10 O 10 <br /> INSULATION PER MANUFACTURERS OF ALL ASPHALTIC MATERIALS O O <br /> SPECIFICATIONS AND LOCAL CODESTAINLESS STEEL CLAMP BAND PRIOR TO SEALING 3 W� <br /> REQUIREMENTS. <br /> NOTE: ROOF PLAN Z <br /> ONE PITCH PAN SHALL BE SCALE: I/8" = I'-0" <br /> RED ROSIN PAPER REFER TO STD. ROOFING CONSTRUCTED FOR EACH CONDUIT. _ <br /> SECTION AND PARAPET CONDUITS SHALL BE SPACED 24" <br /> 7777 PLYWOOD OR WAFERBOARD DECK FLASHING DETAIL FORO.C. MIN. FOR SEPERATE FLASHING <br /> ADDITIONAL INFORMATION CONSTRUCTION. <br /> SMOOTH ALL EDGES (TYP. <br /> SEE CONSTRUCTION SPECIFICATIONS ) v <br /> BOOK SECTION 07510 24 GA. GALV. STEEL PITCH PAN. z <br /> STANDARD ROOFING SECTION 24 GA. GALV. STEEL RAIN CAP FIELD SOLDER ALL SEAMS. SET �� Ln <br /> FIELD SOLDER ALL SEAMS FLANGE IN MODIFIED BITUMEN w > O <br /> 1 SCALE: 3" = I'-0" CEMENT AND NAIL AT 3" O.C. <br /> 2>> PRIME FLANGE BEFORE FLASHING c� Ln Ln <br /> z_ <br /> NOTE � � � <br /> 10" MIN. ° ° 2 COMPONENT URETHANE POURABLE ALL ROOFING DETAILS TO BE VERIFIED Lj_j <br /> 01 <br /> SEALER, SLOPED TO SHED WATER AND COORDINATED WITH MANUFACTURERS <br /> TOP NAIL FLASHING AT 4" O.C. MIN. 4" a p SPECIFICATIONS AND WARRANTIES. O Q Ln <br /> BEAD OF MODIFIED z a- <br /> 2 PLY MODIFIED BITUMEN FLASHING PER MFR MIN. ° I w � O <br /> BITUMEN-CEMENT ::� O <br /> SPECIFICATIONS - SEAL LAPS AND CORNERS w <br /> WITH MODIFIED BITUMEN CEMENT AND FABRIC Q Q Ln <br /> a ° STEEL PLATFORM <br /> PERLITE CANT - SOLID a WITH SAFETY TREAD Q C 0 Ld <br /> MOPPED (IF NO METAL W Q:� Z <br /> CANT EXISTS) _ <br /> a > O <br /> Ln° <br /> 00 MODIFIED BITUMEN FR CAP SHEET ° TOP OF PARAPET N J <br /> PER MFR. SPECIFICATIONS - MOPPED IN • <br /> ASPHALT <br /> P.T. WOOD NAILERS TO MATCH <br /> 4" 4" HEIGHT OF INSULATION, FASTENED 7" �" <br /> MODIFIED BITUMEN BASE SHEET PER MFR. CONDUIT - ONE MAXIMUM PER PITCH PAN POSITIVELY TO DECK LEG OF COMPRESSOR MIN. MIN. <br /> SPECIFICATIONS - MOPPED IN ASPHALT / 0 0 <br /> PITCH PAN DETAIL IL CONCRETE FILLER ISOLATOR,LLEAVE O1/8"TSLACK <br /> RESS &x4N10 tx3/8" WITH 7"x3/8" STEEL TFULL <br /> 5 SCALE: 3" - I'-O" !y WELDS BETWEEN PLATES. <br /> "/-�REFER TO STANDARD ROOFING SECTION VIBRATION ISOLATOR PADS WELD TO STEEL RAILS. <br /> © 48" O.C. VERTICAL (MIN.) LO <br /> 4" WF STRUCTURAL STEEL o o NOTE: LENGTH OF PLATE rn[,- <br /> 4" X 4" X 1/4" STEEL PLATE AS REQUIRED TO PROVIDE <br /> SEE CONSTRUCTION SPECIFICATIONS WELD PLATE TO BEAM AND COLUMN REQUIRED 7" TOE CLEARANCE. U It <br /> BOOK - SECTION 07510 ' <br /> _ 2 1/2"0 O.D. PIPE COLUMN � d o .,� U <br /> SEALANT <br /> STANDARD BASE FLASHING CONFIGURATION = MEMBRANE TAPE o O <br /> LEAD FLASHING SET IN MODIFIED F . �..� � <br /> 2 BITUMEN CEMENT ALUM. HOOD W/ ADJUSTABLE r J"� }X <br /> SCALE: 3" = I'-0" SOIL PIPE PENETRATION TYP. EA. S.S. WORM GEAR HOSE CLAMP �,/ <br /> 1/4" MASTIC © EDGES OF MEMBRANE d� �FRI� /I O N <br /> REFER TO STD. ROOFING w C'T LL <br /> END VJ <br /> SECTION AND BASE < M 4 # SHEET LEAD COLLAR W/ o r� =o <br /> FLASHING DETAIL FOR i� W INTEGRAL ROOF FLANGES Lu o <br /> ADDITIONAL INFORMATION 0 <br /> w SET IN MASTIC <br /> BASE FLASHING Un <br /> SEAL AROUND PIPE WITH 5 w z CONNECTION OPTIONS: ' p L ■ <br /> 2" FT. MIN SLOPE BEAD OF MODIFIED BITUMEN CEMENT MASTIC TO PREVENT BITUMEN z o BUILT-UP MINERAL SURFACE WOOD (2) 5/8"4 x3" LAG BOLTS <br /> REFER TO STANDARD 1� DRIPPAGE BELOW THE DECK o <br /> ROOFING SECTION FOR 00 o INTO VERTICAL STUDS OR J M <br /> LO <br /> ADDITIONAL INFORMATION WOOD BLOCKING. O <br /> U� ■ <br /> Z Lu <br /> CMU 2 5/8"0 x3" WEDGE <br /> J <br /> INSULATION AS INDICATED ANCHOR BOLTS IN SOLID o <br /> ON ROOF PLAN GROUT FILLED CELLS. o0 <br /> 0 <br /> 00 STEEL (2) 5/8"0 x3" LAG BOLTS <br /> IN WOOD BLOCKING/INSERTS ■ <br /> EXISTING PLYWOOD DECK CONNECTED TO STEEL STUDS <br /> 4 1/2" X 4 1/2" X 1/4" STEEL PLATE <br /> 2X12 BRASING o <br /> SCREW AT 6" O.C. RIPPED WOOD BLOCKING OR WD BLOCKING <br /> SECURITY FENCE: <br /> 5/8" CDX PLYWOOD DECKING <br /> RIGID INSULATION CUT TO LAG BOLTS EXPANDED MTL. MESH <br /> OR _ CORRECT SIZE TO DEVELOP 10" 1/2"4" WELD TO 1 MTL. ANGLE FRAME <br /> (UBC/STD 5-25)AFERBOARD ROOF SLOPE MIN. MIN. o LADDERAND STEELPAINT ��ZSEER * 6f <br /> ROOF TRUSS �y o <br /> N O <br /> TYPICAL CRICKET DETAIL SOIL PIPE FLASHING DETAIL EQUIPMENT STAND DETAIL GATE: EXP. MTL. MESH � COo ,a a <br /> (� ON 1" MTL. ANGLE rc <br /> C SCALE: 3" = I'-0" FRAME. PAINT. INSTALL w <br /> VERIFY W/ EQUIPMENT SUPPLIER IF IN CONTRACT. o W/ H.D. HINGE @ <br /> TOP AND BOTT. AND <br /> PADLOCK HARDWARE <br /> CLEARANCE BELOW RAISED ROOF MOUNTED (HINGE AND PADLOCK d <br /> HARDWARE TO BE <br /> MECHANICAL UNITS INCHES <br /> NOTE: MODIFIED BITUMEN SCUPPER ) WELDED TO LADDER) <br /> SCUPPER HEIGHT TO BE FLASHING WIDTH MINIMUM CLEARANCE o 0 <br /> AS PER CODE MODIFIED BITUMEN SCUPPER OF UNIT ABOVE ROOF SURFACE to • <br /> BUT NOT MORE THAN 1" ABOVE FLASHING <br /> THE LOW POINT OF THE ROOF. SET SCUPPER FLANGES IN < 24 14 3/4"0x2'-0" STL. RODS <br /> 8 I MODIFIED BITUMEN CEMENT, 24 < 36 18 © 12" O.C. VERT. <br /> (10" WIDE) FASTEN AT 4" O.C. AND 24 GA. PREFINISHED STEEL 36 < 48 24 <br /> SECURED TO 2x1 4 <br /> z PRIME. SCUPPER FLANGES CONTINUOUS FACE PLATE 48 < 60 30 o STL. RAILS (STRINGER) <br /> 24 GA. PREFINISHED STEEL <br /> C° SHALL BE CONTINUOUS 4" NOTE: <br /> > 60 48 7' CLEAR (MIN.) BETWEEN w <br /> MINIMUM ON ALL SIDES 8x16, 24 GA. PREFINISHED STEEL LADDER RUNG & WALL. `" Z <br /> CONTINUOUS FACE PLATE � z <br /> SURROUNDING OPENING. SCUPPER INSERT TO MATCH w <br /> 5x8, 24 GA. PREFINISHED STEEL z ALL JOINTS SHALL BE POP EXTERIOR FINISH o <br /> SCUPPER INSERT TO MATCH RIVETED AND SEALED <br /> EXTERIOR FINISH _ z DRAIN LINE SLOPE C <br /> SEAL OUTER EDGE OF FROM A/C UNIT AS REQUIRED TO w <br /> ELASTOMERIC SEALANT (TYP) FLASHING WITH MODIFIED DRIAN CONNECTION Q <br /> ITUMCN CE ENT AND FABRIC P-TRAP o <br /> (MIN.) <br /> a CONDENSATE LINE(REF. PLAN) W NOTES: NOTES: Lu un <br /> c� J <br /> i i i i � REFER TO WALL 1. LADDER TO BE OSHA COMPLIANT � N <br /> a SECTIONS FOR WALL m Li Q <br /> DESIGNER NOTE: TERMINATE AT CONSTRUCTION NOTES. 2. LADDER TO BE FULLY WELDED. LLJ <br /> GALVANIZED PRIMARY AND SECONDARY SCUPPERS ROOF SCUPPER ° w Z 0 <br /> METAL LEADER HEAD TO BE SIZED IN ACCORDANCE WITH 3 WALL FINISHES. PRIOR TO cn - o <br /> CHAPTER 11, INTERNATIONAL PLUMBING <br /> 2X WOOD BLOCKING CODE OR LOCAL GOVERNING CODES. (MIN) NOTE: 0 4. ALL STEEL TO BE HOT- w o o Z <br /> FOR FINISH MATERIAL PROVIDE DRAIN NUT " DIPPED GALVANIZED. Q N�/ 0, N Q <br /> IN BOTTOM OF P-TRAP rn �_ LL J z <br /> REFER TO BUILDING o <br /> ROOF 5. PAINT PER SHEET A-2 o ,,W Q <br /> ELEVATIONS. PIPE SUPPORT 6. PROVIDE SHOP DRAWINGS o V = z IZ <br /> PEDESTALS PLACED �n _ <br /> 6x6 SEAMLESS ALUMINUM OR PRODUCT SPECIFICATION o N " o <br /> 5'-0' O.C. & ALL TURNS, L' w Y LL <br /> DOWNSPOUT. JUNCTION IN LINES. o� � = 0 0 0 <br /> (WOOD BLOCKING NOT ALLOWED) /� <br /> 14 cr< 0 W N 0cf) 0 <br /> NOTE: REF. DTL 4/A-5 FOR TYPICAL NOTES. <br /> ��7�SCUPPER & ROOF GUTTER DETAIL 7 OVERFLOW SCUPPER DETAIL Q CONDENSATE LINE SUPPORT DETAIL ROOF LADDER DETAILA 5 <br /> SCALE: 3 SCALE: 3 - I -O �+ SCALE: NONE 10 SCALE: 3/4 = 1 '-0" <br />
The URL can be used to link to this page
Your browser does not support the video tag.