Laserfiche WebLink
S A N ,J a AQ U I Environmental Health Department <br /> Corrective Action Statement <br /> RE: October 05, 2021, Aboveground Petroleum Storage Act inspection report <br /> For each violation listed below,indicate if the violation has been corrected or will be corrected by a certain date. Also, <br /> describe what was done to correct the violation in the space provided below each violation. Submit this completed <br /> form with the Return to Compliance Certification within 30 days of inspection. If you have any questions,please <br /> contact Carol Presto at(209)616-3061 or cpresto@sjgov.org. <br /> AAFES WEST COAST DISTRIB CENTER, 700 E ROTH RD, CERS ID: 10187011, PRO527961 <br /> Violation#610-Plan failed to adequately detail information and procedures for reporting a discharge. <br /> XThis violation was corrected ❑This violation will be corrected by(date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: Andreas Rosales is no longer at the facility. <br /> Rosales was replaced throughout the SPCC Plan with Damon Jackson. His contact information <br /> is provided in Section 4.1 of the revised SPCC Plan and Section 4.4 was added to <br /> include contact information for Fremouw Environmental Services. <br /> Violation 0712-Failed to perform scheduled tank tests or inspections by appropriately qualified personnel. <br /> XThis violation was corrected ❑This violation will be corrected by(date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: The formal external inspection Of the 12,000- <br /> gallon AST was conducted by a STI SP001-certified inspector on 11/4/2021. The inspector also <br /> trained AAFES personnel to properly conduct monthly and annual tank inspections. AAFES <br /> >>ersonnel will ensure required inspections are conducted in the future. <br /> Violation#716-Failed to regularly test liquid level sensing devices to ensure proper operation. <br /> XThis violation was corrected ❑This violation will be corrected by(date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: The STI SP001 inspector checked the level gauge on each of the tanks <br /> while onsite on 11/4/2021 and showed AAFES personnel how to check the gauges each year to ensure proper operation.Personnel will manually <br /> stick all three tanks or will add a known amount of product to the tank to gauge proper function of gauges in future years.In addition,Section 3.5 <br /> and Table 3-1 of the SPCC Plan were revised to include annual testing of liquid level gauges on all three tanks. <br /> Page 3 of 4 <br /> Rev.9/16/2020 <br /> 1868 E. Hazelton Avenue I Stockton,California 962051 T 209 468-34201 F 209 464-0138 1 www.sjgov.org/EHD <br />