ANNUAL TEST FAIL NOV 19, 2021 10:05 AM <br /> ALARM DISABLED <br /> LEAK TEST METHOD <br /> TEST ON DATE : ALL TANK <br /> -------------- ---- <br /> IAN 29, 2009 <br /> Request: 60 - 163100 - Tank Leak Test Averaging START TIME : DISABLED <br /> Request Source: Monitor system configuration Requests - TEST RATE :0.20 GAL/HR <br /> Line: 60 DURATION : 2 HOURS <br /> TST EARLY STOP:DISABLED <br /> 163100 <br /> NOV 19, 2021 10:05 AM =--------------------------- <br /> Request: 66 - 161300 - CSLD Probability of Detection <br /> TANK LEAK TEST AVERAGING Request Source: Monitor system Configuration Requests - <br /> Line: 66 <br /> TANK PRODUCT LABEL ANNUAL PERIODIC <br /> 1 SUPER OFF OFF <br /> 2 UNLEADED 1 OFF OFF <br /> 3 UNLEADED 2 OFF OFF 161300 <br /> 4 OFF OFF NOV 19, 2021 10:05 AM <br /> CSLD PROBABLITY OF DETECTION <br /> Request: 61 - 163000 - Tank Leak Test notify <br /> Request Source: Monitor system configuration Requests - ---------------------------- <br /> Line: 61 Request: 67 - 161400 - CSLD climate Factor <br /> Request Source: Monitor system configuration Requests - <br /> Line: 67 <br /> 163000 <br /> NOV 19, 2021 10:05 AM <br /> 161400 <br /> IN-TANK LEAK TEST NOTIFY NOV 19, 2021 10:05 AM <br /> CSLD CLIMATE FACTOR <br /> TANK PRODUCT LABEL TANK TEST NOTIFY: <br /> 1 SUPER OFF <br /> 2 UNLEADED 1 OFF <br /> 3 UNLEADED 2 OFF =--------------------------- <br /> ______________ <br /> 4 OFF Request: 68 - 161600 - Accuchart Update scheduling <br /> Request Source: Monitor system Configuration Requests - <br /> Line: 68 <br /> ---------------------------- <br /> ---------------------------- <br /> Request: 62 - 163200 - Tank Test Siphon Break <br /> Request Source: Monitor system Configuration Requests - <br /> Line: 62 161600 <br /> NOV 19, 2021 10:05 AM <br /> TANK PRODUCT LABEL CAL UPDATE <br /> 163200 1 SUPER IMMEDIATE <br /> NOV 19, 2021 10:05 AM 2 UNLEADED 1 IMMEDIATE <br /> 3 UNLEADED 2 IMMEDIATE <br /> TANK TEST SIPHON BREAK 4 IMMEDIATE <br /> TANK PRODUCT LABEL SIPHON BREAK <br /> 1 SUPER OFF <br /> 2 UNLEADED 1 OFF Request: 69 - 161A00 - In-Tank Leak Test Early Stop <br /> 3 UNLEADED 2 OFF Request Source: Monitor system Configuration Requests - <br /> 4 OFF Line: 69 <br /> Request: 63 - 161000 - Tank delivery Delay MA00 <br /> Request Source: Monitor system configuration Requests - NOV 19, 2021 10:05 AM <br /> Line: 63 <br /> IN-TANK LEAK TEST EARLY STOP <br /> TANK PRODUCT LABEL TST EARLY STOP: <br /> 161000 1 SUPER DISABLED <br /> NOV 19, 2021 10:05 AM 2 UNLEADED 1 DISABLED <br /> 3 UNLEADED 2 DISABLED <br /> TANK DELIVERY DELAY 4 DISABLED <br /> TANK PRODUCT LABEL =--------------------------- <br /> _______________ _ <br /> 1 SUPER 1 Request: 70 - 161BOO - In-Tank Static Gross Test Auto- <br /> 2 UNLEADED 1 1 Confirm <br /> 3 UNLEADED 2 1 Request Source: Monitor system Configuration Requests - <br /> 4 1 Line: 70 <br /> ---------------------------- <br /> ---------------------------- <br /> Request: 64 - 163A00 - Tank low Level Threshold for Line <br /> Manifold 161800 <br /> Request Source: Monitor system configuration Requests - NOV 19, 2021 10:05 AM <br /> Line: 64 <br /> IN-TANK LEAK GROSS TEST AUTO-CONFIRM <br /> 163A00 <br /> NOV 19, 2021 10:05 AM =--------------------------- <br /> ----- --------- <br /> Request: 71 - 161C00 - CSLD Report only mode <br /> LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD Request Source: Monitor system Configuration Requests - <br /> Line: 71 <br /> TANK PRODUCT LABEL PUMP THRESHOLD <br /> 1 SUPER 10.00% <br /> 2 UNLEADED 1 10.00% <br /> 3 UNLEADED 2 10.00% MOO <br /> 4 10.00% NOV 19, 2021 10:05 AM <br /> CSLD REPORT ONLY <br /> Request: 65 - 161100 - Tank Leak Test Type and Start Time <br /> Request Source: Monitor system configuration Requests - <br /> Line: 65 =--------------------------- <br /> --------------- ---- <br /> Request: 72 - 162B00 - Tank Last Annual Test <br /> Request Source: Monitor system configuration Requests - <br /> Line: 72 <br /> 161100 <br /> 6 <br />