REVISIONS
<br /> TENTATIVE IMPROVEMENT PLANS FOR: REV DATE DESCRIPTION
<br /> PRIME MARKET 234 WEST YOSEMITE AVE MANTECA CA 95336
<br /> 4
<br /> EXISTING CONDITIONS: 921-611 LIFE SAVING PLAN NOTES: Expires {�
<br /> MAXIMUM OCCUPANCY =9. THERE ARE(6)FOUR PROPOSED ILLUMINATED EXIT W
<br /> EXISTING VACANT BUILDING(2,650ft2)WITHIN A(7,800W)BUILDING LOCATED EXISTING SIGNS, (2)FIRST AID KITS, (3)PROPOSED FIRE EXTINGUISHERS,(6)PROPOSED a
<br /> AT 234 WEST YOSEMITE AVENUE,CITY OF MANTECA,CA 95336, (LAT: 37.79720, RESTROOM (47ftZ) EMERGENCY STROBES,AND(2)PROPOSED EMERGENCY HORN/STROBE SIGNALS. F "
<br /> LONG: -121.21859)ELEV: 37,WITHIN PARCEL APN: 219-400-01,REVISED MAP OF CEILING HEIGHT–8'-0" `—_ v
<br /> NORTH MANTECA,BOOK 219,PAGE 40,LOT#1,BLDG#7 2019 CALIFORNIA BUILDING CODE
<br /> ZONING: CENTRAL BUSINESS OVERLAY ZONE 1 (CBD).
<br /> CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY AND
<br /> TENTATIVE IMPROVEMENTS: EXISTINGEXISTING USE
<br /> 406 8.2 GAS DETECTION SYSTEM
<br /> OFFICE#1 (176ft)z OFFICE#2(150ft)Z ti
<br /> CEILING HEIGHT– 15'-0" CEILING HEIGHT– 15'-0" REPAIR GARAGES USED FOR REPAIR OF VEHICLES FUELED BY NONODORIZED
<br /> PROPOSED CONVENIENCE STORE "PRIME MARKET" (2,650W)AT GASES INCLUDING BUT NOT LIMITED TO HYDROGEN AND NONODORIZED LNG, v :�
<br /> 234 WEST YOSEMITE AVENUE,CITY OF MANTECA,CA 95336. INSIDE THE SHALL BE PROVIDED WITH A GAS DETECTION SYSTEM THAT COMPLIES WITH Q a °�, A
<br /> MAIN FLOOR IS (1,935ft2)WITH(2)TWO OFFICES, ONE AT(176fe)AND ONE AT kh., SECTION 916. THE GAS DETECTION SYSTEM SHALL BE DESIGNED TO DETECT v .' a,
<br /> (150ft2). THERE IS A BACK STORAGE ROOM AT(218fV)AND A UNISEX y LEAKAGE OF NONODORIZED GASEOUS FUEL.WHERE LUBRICATION OR CHASSIS °' c
<br /> RESTROOM AT(47ftZ). THERE ARE(6) SIX PARKING SPOTS FOR THIS BUILDING SERVICE PITS ARE PROVIDED IN GARAGES USEDFOR REPAIRING NONODORIZED
<br /> AT THE BACK OF THE PROPERTY ON EAST OTIS STREET. THERE ARE (9)NINE EXISTING BUILDING(1,935ft2) LNG FUELED VEHICLES, GAS SENSORS SHALL BE PROVIDED IN SUCH PITS. V) Col
<br /> PARKING SPOTS AND A ADA PARKING SPOT ON THE WEST SIDE OF THIS PROPOSED CONVENIENCE STORE FLOOR W W
<br /> BUILDING CALLED "CROSSROADS PARKING". THIS MERCANTILE STORE HAS 406.8.2.1 SYSTEM ACTIVATION
<br /> CEILING HEIGHT= 15'-0" � o
<br /> A 28'-6"FRONTAGE ON WEST YOSEMITE AVENUE WITH(2)TWO PARKING ACTIVATION OF A GAS DETECTION ALARM SHALL RESULT IN ALL OF THE Q
<br /> SPOTS IN FRONT. Le FOLLOWING: z
<br /> THIS SITE HAS AND EXISTING FRONTAGE ROAD(W.YOSEMITE AVE)ON THE N w 1. INITIATION OF DISTINCT AUDIBLE AND VISUAL ALARM SIGNALS IN THE Z ,
<br /> NORTH SIDE OF THE PROPERTY. REPAIR GARAGE WHERE THE VENTILATION SYSTEM IS INTERLOCKED WITH GAS
<br /> �y DETECTION. C)
<br /> a
<br /> THE EXISTING CITY OF MANTECA STORM ACCESS IS SOUTH AND WEST OFC)
<br /> y ^o a
<br /> THE PROPERTY PROVIDED BY 12" STORM DRAIN GRATES ON(E. OTIS ST.) CHAPTER 10 MEANS OF EGRESS U c
<br /> 00
<br /> – SECTION 1013 EXIT SIGNS v
<br /> THE EXISTING CITY OF MANTECA SEWER ACCESS IS SOUTH OF THIS 1013.1 WHERE REQUIRED. o
<br /> BUILDING BEHIND(E. OTIS ST.) x EXITS AND EXIT ACCESS DOORS SHALL BE MARKED BY AN APPROVED EXIT SIGN Z , @)
<br /> w READILY VISIBLE FROM ANY DIRECTION OF EGRESS TRAVEL. THE PATH OF 8
<br /> THE EXISTING CAL WATER IS BEHIND THIS EXISTING BUILDING IN THE r� x EGRESS TRAVEL TO EXITS AND WITHIN EXITS SHALL BE MARKED BY READILY o, a
<br /> PLANTER BEFORE PARKING. w VISIBLE EXIT SIGNS TO CLEARLY INDICATE THE DIRECTION OF EGRESS TRAVEL e °;
<br /> O IN CASES WHERE THE EXIT OR THE PATH OF EGRESS TRAVEL IS NOT c
<br /> THE EXISTING PG&E GAS UTILITY IS ON THE EAST SIDE OF THIS EXISTING zn W IMMEDIATELY VISIBLE TO THE OCCUPANTS. INTERVENING MEANS OF EGRESS
<br /> BUILDING BEHIND A LOCKED WROUGHT IRON GATE. U DOORS WITHIN EXITS SHALL BE MARKED BY EXIT SIGNS. EXIT SIGN PLACEMENT C O "
<br /> SHALL BE SUCH THAT ANY POINT IN AN EXIT ACCESS CORRIDOR OR EXIT
<br /> YOU MUST CALL CITY OF MANTECA,CAL WATER,AND PG&E FOR PASSAGEWAY IS WITHIN 100 FEET(30 480 MM)OR THE LISTED VIEWING DISTANCE
<br /> PROPOSED TIE-INS/STUB-UPS TO THESE EXISTING UTILITIES. OF THE SIGN,WHICHEVER IS LESS,FROM THE NEAREST VISIBLE EXIT SIGN.
<br /> UTILITY NOTES: 2019 CALIFORNIA FIRE CODE
<br /> THE UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY SYSTEM T 1 O
<br /> INFORMATION AND EXISTING DRAWINGS.THE SURVEYOR MAKES NO GUARANTEE THAT SECTION 906-PORTABLE FIRE EXTINGUISHERS
<br /> THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA,EITHER EXISTING LIFE SAVING PLAN PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED IN ALL OF THE
<br /> IN SERVICE OR ABANDONED.THE SURVEYOR FURTHER DOES NOT GUARANTEE THAT THE C/)FOLLOWING LOCATIONS:
<br /> UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED ALTHOUGH HE SCALE: 3/16"= 1'-0" 1. IN NEW AND EXISTING GROUP A B E F H I L M R-L R-2 R-2.1 R-2.2 R-3.1 R-4 W
<br /> DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM
<br /> INFORMATION AVAILABLE.THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE AND S OCCUPANCIES. Q M
<br /> UNDERGROUND UTILITIES. W N
<br /> 2018 INTERNATIONAL BUILDING CODE
<br /> BUILDING CODE ANALYSIS: CHAPTER 10-MEANS OF EGRESS z W
<br /> DESCRIPTION OF USE: CONVENIENCE STORE SECTION 1009-ACCESSIBLE MEANS OF EGRESS
<br /> OCCUPANCY GROUP: GROUP M SECTION 1009.1 -ACCESSIBLE MEANS OF EGRESS REQUIRED O
<br /> TYPE OF CONSTRUCTION: WOOD&CMU ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITH THIS SECTION.
<br /> FIRE SPRINKLERS: NO ACCESSIBLE SPACES SHALL BE PROVIDED WITH NOT LESS THAN ONE �
<br /> STORIES: 1 ACCESSIBLE MEANS OF EGRESS.WHERE MORE THAN ONE MEANS OF EGRESS IS
<br /> BUILDING HEIGHT: 15'-0" REQUIRED BY SECTION 1006.2 OR 1006.3 FROM ANY ACCESSIBLE SPACE,EACH UW
<br /> ALLOWABLE FLOOR AREA: 2,650ft2 ACCESSIBLE PORTION OF THE SPACE SHALL BE SERVED BY ACCESSIBLE MEANS M
<br /> FLOOR AREA: 2,650fF OF EGRESS IN AT LEAST THE SAME NUMBER AS REQUIRED BY SECTIONS 1006.2 z N
<br /> OCCUPANCY LOAD(CBC): 40 MAX. OR 1006.3. IN ADDITION TO THE REQUIREMENTS OF THIS CHAPTER,MEANS OF
<br /> OCCUPANCY LOAD(CPC): 40 MAX. EGRESS,WHICH PROVIDE ACCESS TO,OR EGRESS FROM,BUILDINGS FOR M--�
<br /> PERSONS WITH DISABILITIES, SHALL ALSO COMPLY WITH THE REQUIREMENTS Q
<br /> LEGEND OF CHAPTER 11A OR 11B AS APPLICABLE.
<br /> EXIT ILLUMINATED EXIT SIGN
<br /> a DUAL SECURITY LIGHTS
<br /> ALARM
<br /> W z
<br /> FIRST AID KIT
<br /> FIRE EXTINGUISHER
<br /> � ACCESSIBLE MEANS OF EGRESS z W
<br /> NOTE: ALL EXITS O
<br /> AND UNLOCKED ATALL 4TIMES Ow
<br /> AND OPEN ��
<br /> WITHOUT OPERATION OR INTERIOR KEYED LOCKS
<br /> � O N
<br /> EXIT REQUIREMENTS -NUMBER&ARRANGEMENT OF EXIST SECTION 706-TABLE 706.4
<br /> EXIT ROOM OR SPACE
<br /> MIN. #OF EXITS TVL. DIST. BTW.DOORS MEANS OF EGRESS FIRE WALLS FIRE RESISTANCE RATINGS
<br /> DESIGNATION REQUIRED SHOWN ALLOW(FT) ACTUAL(FT) REQUIRED ACTUAL GROUP FIRE-RESISTANCE
<br /> RATING(HOURS) UNAUTHORIZED CHANGES&USES:
<br /> The design firm preparing these plans will not be responsible for,or liable for,
<br /> ONE LEVEL 2 2 100 92 2 2 V-B 2 unauthorized changes to or uses of these plans.All changes to these plans MUST be in
<br /> THE ISSUANCE OF A PERMIT OR APPROVAL OF PLANS OR SPECIFICATIONS 2019 CALIFORNIA BUILDING CODE-CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES writing and must be approved by the preparer of these plans.
<br /> SHALL NOT BE DEEMED OR CONSTRUED TO BE A PERMIT FOR AN
<br /> APPROVAL OF ANY VIOLATION OF ANY OF THE PROVISIONS OF THE
<br /> CALIFORNIA STATE BUILDING CODES OR LOCAL ORDINANCES. SECTION 1006-TABLE 1006.2.1 SECTION 1017-TABLE 1017.2 EXIT ACCESS TRAVEL DESIGN BY: G.MENDOZ
<br /> SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY DISTANCE LIFE SAFETY SYSTEM REQUIREMENTS: Construction contractor agrees that in accordance with generally acepted construction
<br /> practices,construction contractor will be required to assume sole and complete DRAWN BY: G.MENDOZ
<br /> W/O SPRINKLER W/O SPRINKLER W/SPRINKLER Emergency Lighting: ❑No ■Yes Responsibility for job site conditions during the course of constructionof the project
<br /> MAX. OCCUPANT g ySCALE: SCALE: 3/16"= 1'-0"
<br /> NOTE: ELETRONIC VERSIONS OF THE LINEWORK ON THIS PLAN MAY NOT OCCUPANCY LOAD OF SPACE SYSTEM(FT) OCCUPANCY SYSTEM(FT) SYSTEM(FT) including safety of all persons and property;that this requirement shall be made to apply
<br /> BE CONSISTANT WITH OTHER DIMENSIONS,NOTES,DETAILS,OR OCCUPANT LOAD Exit Signs: ❑No ■Yes
<br /> continuously and not to be limited to normal working hours, and construction contractor DATE: 11/26/2020
<br /> DESCRIPTIONS WHICH CONTROL THE INTENT DESIGN.ELECTRONIC FIre Alarm: ❑No ■Yes further agrees to defend,imdemnify and hold design professional harmless from any
<br /> VERSIONS OF THE PLAN ARE NOT TO BE USED TO ESTABLISH THE MERCANTILE-M 49 75 MERCANTILE-M 200 250 Smoke Detection Systems: ❑No ■Yes and all liability,real or alleged,in connection with the performance of work on this
<br /> LOCATION OF PROPERTY OR IMPROVEMENTS IN THE FIELD. 2019 CALIFORNIA BUILDING CODE-CHAPTER 10 MEANS OF EGRESS 2019 CALIFORNIA BUILDING CODE-CHAPTER 10 MEANS OF EGRESS Panic Hardware: ❑No ■Yes project, except liability arising from the sole negligence of the design professional.
<br /> Fl