My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
232
>
1600 - Food Program
>
PR0547201
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/15/2023 2:25:25 PM
Creation date
10/12/2021 3:23:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0547201
PE
1618
FACILITY_ID
FA0026785
FACILITY_NAME
PRIME MARKET
STREET_NUMBER
232
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
232 W YOSEMITE AVE
P_LOCATION
04
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REVISIONS <br /> TENTATIVE IMPROVEMENT PLANS FOR: REV DATE DESCRIPTION <br /> PRIME MARKET 234 WEST YOSEMITE AVE MANTECA CA 95336 <br /> 4 <br /> TENTATIVE IMPROVEMENTS: 921-611 2019 CALIFORNIA BUILDING CODE Expires <br /> CHAPTER 3 BUILDING BLOCKS W <br /> PROPOSED CONVENIENCE STORE "PRIME MARKET" (2,650W)AT 55'-6" 13'-6" 11'-6" 9'-6" 11B-305 CLEAR FLOOR OR GROUND SPACE <br /> 234 WEST YOSEMITE AVENUE,CITY OF MANTECA,CA 95336. INSIDE THE 1113-305.3 SIZE <br /> MAIN FLOOR IS (1,935ft2)WITH(2)TWO OFFICES, ONE AT(176fe)AND ONE THE CLEAR FLOOR OR GROUND SPACE SHALL BE 30" MIN. BY 48" MAX. _ F <br /> �v <br /> AT(I 50W). THERE IS A BACK STORAGE ROOM AT(218fV)AND A UNISEX <br /> RESTROOM AT(47ftz). THERE ARE(6) SIX PARKING SPOTS FOR THIS I IB-308 REACH RANGES <br /> BUILDING AT THE BACK OF THE PROPERTY ON EAST OTIS STREET. THERE 1113-308.3.2. OBSTRUCTED HIGH REACH <br /> ARE (9)NINE PARKING SPOTS AND A ADA PARKING SPOT ON THE WEST d WHERE A CLEAR FLOOR OR GROUND SPACE ALLOWS A PARALLEL <br /> SIDE OF THIS BUILDING CALLED "CROSSROADS PARKING". THIS APPROACH TO AN ELEMENT AND THE HIGH SIDE REACH IS OVER AN V J b <br /> MERCANTILE STORE HAS A 28'-6" FRONTAGE ON WEST YOSEMITE AVENUE DISPLAY 14X2.5 SHELVING SHELVING SHELVING EXISTING z OBSTRUCTION, THE HEIGHT OF THE OBSTRUCTION SHALL BE 34"MAX. <br /> r, RESTROOM (47ft) AND THE DEPTH OF THE OBSTRUCTION SHALL BE 24"MAX. THE HIGH SIDE �4v <br /> WITH(2)TWO PARKING SPOTS IN FRONT. N PROP. FLIP UP ACCESS CEILING HEIGHT-8'-0" <br /> n „ ISLE WAY 3-0 WIDE - REACH SHALL BE 48 MAX.FOR A REACH DEPTH OF 10 MAX.WHERE THE o s~ u ca <br /> N O v, COUNTER 3X2.5X2 1113-604.8.2 O 'a 8 <br /> PROP. FLOOR(1) 1 HIGH U 1113-305.3 O REACH DEPTH EXCEEDS 10" THE HIGH SIDE REACH SHALL BE 46"MAX. = "" v 9 <br /> THIS SITE HAS AND EXISTING FRONTAGE ROAD(W.YOSEMITE AVE)ON - rNS (BY G.C. OR OTHERS) Q „ v . <br /> o (2)HANGING LIGHTS EXISTING EXISTING N FOR A REACH DEPTH OF 24 MAX. <br /> THE NORTH SIDE OF THE PROPERTY. o; o0 <br /> o D o INTERNET&PHONE <br /> W 00 <br /> �' SOft2 10x5 51-011 3'-0" 5'-3" OFFICE#1 (176ft2) OFFICE#2 (150ft2) Z o o q� a F" t <br /> ( ) 1113-305.3 SHELVING SHELVING W I IB-404 DOORS,DOORWAYS,AND GATES <br /> THE EXISTING CITY OF MANTECA STORM ACCESS IS SOUTH AND WEST OF (TYP.) 1113-305.3 CEILING HEIGHT=8'-0" CEILING HEIGHT= 15'-0" 3 DOOR y pa I IB-404.2.3 CLEAR WIDTH W r <br /> THE PROPERTY PROVIDED BY 12" STORM DRAIN GRATES ON(E. OTIS ST.) -" 1113-404.2.3 - !�! <br /> O COUNTER lOX2.5X34" w -� DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32"MINIMUM. � � o <br /> 11 B-703.7.2.1 <br /> ORS SHALL BE <br /> THE EXISTING CITY OF MANTECA SEWER ACCESS IS SOUTH OF THIS U 1113-308.3.2 EXISTING BUILDING(1,935ft2) o iE EX' 15X0" TALL 4"POST ISLE WA13Y3'03 WIDE M MEASURE BETWEOPENINGS OEN TOHE FACE OF THE DOOR AND TORWAYS WITH SWINGING OHE STOP,WITH THE Z <br /> BUILDING BEHIND(E. OTIS ST.) PROP. CONVENIENCE STORE H <br /> 4 Q SEE SPEC FOR _ CEILING HEIGHT= 15'-0" DOUBLE DOOR DOOR OPEN 90 DEGREES. OPENINGS MORE THAN 24"DEEP SHALL PROVIDE <br /> DRY DISPLAY CASE x 3'DOOR A CLEAR OPENING OF 36" MINIMUM. THERE SHALL BE NO PROJECTIONS <br /> THE EXISTING CAL WATER IS BEHIND THIS EXISTING BUILDING IN THE 5-6 o M M 1113-404.2.3 11B-404.2.3 = INTO THE REQUIRED CLEAR OPENING WIDTH LOWER THAN 34"ABOVE <br /> PLANTER BEFORE PARKING. - COUNTER + N THE FINISH FLOOR OR GROUND.PROJECTIONS INTO THE CLEAR OPENING a <br /> p o 2.5X2.5X34 3'-0" C) <br /> �C a; ( ) -� WIDTH BETWEEN 34 AND 80 ABOVE THE FINISH FLOOR OR GROUND E <br /> THE EXISTING PG&E GAS UTILITY IS ON THE EAST SIDE OF THIS EXISTING- oo �n w pap 1113-308.3.2 TYp '? °O „ <br /> BUILDING BEHIND A LOCKED WROUGHT IRON GATE. A C7 C7 C7 C7 C7 N o SHALL NOT EXCEED 4". U c <br /> ;r, r� PROP. 3'-0"DOOR <br /> a C7 > M > > > > H O CHAPTER 6 PLUMBING ELEMENTS AND FACILITIES <br /> YOU MUST CALL CITY OF MANTECA,CAL WATER,AND PG&E FOR 4 12 6„ W W (EMPLOYEE ACCESS ONLY) y � O W v <br /> W o W W W W 11B-604 WATER CLOSETS AND TOILET COMPARTMENTS <br /> PROPOSED TIE-INS/STUB-UPS TO THESE EXISTING UTILITIES. > x M x x x x I IB-404.2.3 as x <br /> a un v, un un w �7 I IB-604.2 LOCATION <br /> UTILITY NOTES: <br /> THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR PARTITION <br /> SHELVING W TO THE REAR AND TO ONE SIDE. THE CENTER-LINE OF THE WATER e °; <br /> THE UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY 31_0" U CLOSET SHALL BE 17MIN. TO 18"MAX.FROM THE SIDE WALL OR ° <br /> INFORMATION AND EXISTING DRAWINGS.THE SURVEYOR MAKES NO GUARANTEE THAT 4'-6" 1113-305.3 PARTITION.WATER CLOSETS SHALL BE ARRANGED FOR A LEFT-HAND OR a3 a, <br /> THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, o ISLE WAY 3'-8"WIDE °O 1113-305.3 RIGHT-HAND APPROACH. <br /> EITHER IN SERVICE OR ABANDONED.THE SURVEYOR FURTHER DOES NOT GUARANTEE o 1113-305.3 `Y' <br /> THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED 1113-604.8 TOILET COMPARTMENTS <br /> ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE <br /> FROM INFORMATION AVAILABLE.THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE COUNTER 1113-604.8.2 AMBULATORY ACCESSIBLE COMPARTMENTS. <br /> UNDERGROUND UTILITIES. 6X3X34" MERCHANDISER MERCHANDISER MERCHANDISER FREEZER COOLER AMBULATORY ACCESSIBLE COMPARTMENTS SHALL COMPLY WITHSECTION 1113-604.8.2. <br /> w <br /> BUILDING CODE ANALYSIS: a 1113-308.3.2 <br /> 11B-604.8.2.1 SIZE. T 1 Q <br /> DESCRIPTION OF USE: CONVENIENCE STORE AMBULATORY ACCESSIBLE COMPARTMENTS SHALL HAVE A DEPTH OF 60 <br /> OCCUPANCY GROUP: GROUP M 3'-0" ADA SIGN INCHES {1524 MM)MINIMUM AND A WIDTH OF 35 INCHES {889 MM) v1 Iw-I <br /> TYPE OF CONSTRUCTION: WOOD&CMU <br /> MINIMUM AND 37 INCHES (940 MM)MAXIMUM. <br /> FIRE SPRINKLERS: NO <br /> STORIES: 1 11B-606 LAVATORIES AND SINKS <br /> BUILDING HEIGHT: 15'-0" 11B-606.6 ADJACENT SIDE WALL OR PARTITION Q ^ Z 5 w N <br /> ALLOWABLE FLOOR AREA: 2,650ftz LAVATORIES,WHEN LOCATED ADJACENT TO A SIDE WALL OR PARTITION, <br /> FLOOR AREA: 2,650ft SHALL BE A MINIMUM OF 18" TO THE CENTERLINE OF THE FIXTURE. Q M---I W N <br /> OCCUPANCY LOAD(CBC): 40 MAX. Z 4 <br /> OCCUPANCY LOAD(CPC): 40 MAX. CHAPTER 7 : COMMUNICATION ELEMENTS AND FEATURES ?W w C <br /> I IB-703 SIGNS > Q W <br /> 1113-703.7.2 SYMBOLS <br /> 1113-703.7.2.1 INTERNATIONAL SYMBOL OF ACCESSIBILITY <br /> THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL COMPLY WITH Wo <br /> FIGURE I IB-703.7.2.1. THE SYMBOL SHALL CONSIST OF A WHITE FIGURE U <br /> ON A BLUE BACKGROUND. THE COLOR BLUE SHALL APPROXIMATE FS M <br /> 15090 IN FEDERAL STANDARD 595C.A BORDER MAY BE PROVIDED INSIDE <br /> OR OUTSIDE OF THE MINIMUM REQUIRED INTERNATIONAL SYMBOL OF <br /> ACCESSIBILITY DIMENSION. ^-� <br /> 1113-703.7.2.1 � Q <br /> NO <br /> 2019 CALIFORNIA GREEN CODE <br /> ADA COMPLIANCE PLAN <br /> PARKING ON <br /> SCALE: 1" -20'-0" SECTPCHATERS 303 INDOOR WATER MANDATORY MEASURES <br /> 5.303.3 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS. <br /> PLUMBING FIXTURES (WATER CLOSETS AND URINALS)AND FITTINGS <br /> (FAUCETS AND SHOWERHEADS) SHALL COMPLY WITH THE FOLLOWING: <br /> 48 n 5.303.3.1 WATER CLOSETS. <br /> THE EFFECTIVE FLUSH VOLUME OF ALL WATER CLOSETS SHALL NOT ~J <br /> 1219 EXCEED 1.28 GALLONS PER FLUSH. TANK-TYPE WATER CLOSETS SHALL <br /> BE CERTIFIED TO THE PERFORMANCE CRITERIA OF THE U.S. EPA WATER <br /> SENSE SPECIFICATION FOR TANK-TYPE TOILETS. 1 w <br /> re pu Nva'dN riensfa� (�-�I <br /> �4 <br /> 5.303.3.4 FAUCETS AND FOUNTAINS. F- -I <br /> - 5.303.3.4.1 NONRESIDENTIAL LAVATORY FAUCETS. Q <br /> LAVATORY FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF NOT W <br /> • ! � � � � MORE THAN 0.5 GALLONS PER MINUTE AT 60 PSI. Q ~J <br /> ADA PARKING DETAIL <br /> PARKING SPACE AND ACCESS AISLE <br /> 5'-0" 9,-0„ CAR v <br /> '. a V1 <br /> ACCESS ------------_=------------- � <br /> Do <br /> ISLE P ADA <br /> SIGN - FIGURE 11B-305,3 <br /> FIGURE 1113-703.7.2,1 CLEAR FLOOR OR GROUND SPACE <br /> INTERNATIONAL SYMBOL OF ACCESSIBILITY <br /> BLUE o <br /> BORDER O M <br /> N <br /> 1113-308.3.2. OBSTRUCTED HIGH REACH � ^ <br /> Z^ 11B-404.2.3 CLEAR WIDTH '-�--� <br /> -i _ <br /> 32 rd'n UNAUTHORIZED CHANGES&USES: O <br /> HATCHED a� The design firm preparing these plans will not be responsible for,or liable for, <br /> LINES AT OZ 35,_3 unauthorized changes to or uses of these plans.All changes to these plans MUST be in <br /> W writing and must be approved by the preparer of these plans. <br /> THE ISSUANCE OF A PERMIT OR APPROVAL OF PLANS OR SPECIFICATIONS 36" O.C.M. o 889-940 � � <br /> SHALL NOT BE DEEMED OR CONSTRUED TO BE A PERMIT FOR AN T° <br /> 60 <br /> APPROVAL OF ANY VIOLATION OF ANY OF THE PROVISIONS OF THE 4 <br /> CALIFORNIA STATE BUILDING CODES OR LOCAL ORDINANCES. 11B-703.7.2.1 DESIGN BY: G.MENDOZ <br /> { Construction contractor agrees that in accordance with generally acepted construction <br /> NO a practices,construction contractor will be required to assume sole and complete DRAWN BY: G.MENDOZ <br /> PARKING �, hIngod dE)Or 10 max 10-24 max d Responsibility for job site conditions during the course of constructionof the project, SCALE: SCALE: 1" -20'-0" <br /> NOTE: ELETRONIC VERSIONS OF THE LINEWORK ON THIS PLAN MAY NOT 254 764-970 including safety of all persons and property;that this requirement shall be made to apply <br /> BE CONSISTANT WITH OTHER DIMENSIONS,NOTES,DETAILS,OR WHITE LETTERING (b) continuously and not to be limited to normal working hours, and construction contractor DATE: 11/26/2020 <br /> DESCRIPTIONS WHICH CONTROL THE INTENT DESIGN.ELECTRONIC 12"MIN HEIGHT F k G U RE 11 B-404.23 further agrees to defend,imdemnify and hold design professional harmless from any <br /> VERSIONS OF THE PLAN ARE NOT TO BE USED TO ESTABLISH THE FIGURE 1111-604.8.2 FIGURE 118-308.3.2 and all liability,real or alleged,in connection with the performance of work on this <br /> 2019 CALIFORNIA A��o ODE-CHAPTER'ME�C�BU3ILITNY T A PLIC ADA TOILET COMPARTMENT CLEAR WIDTH OF DOORWAYS project, except liability arising from the sole negligence of the design professional. <br /> LOCATION OF PROPERTY OR IMPROVEMENTS IN THE FIELD. HOUSING.DIVISIONS 5-GENERAL SITE AND BUILDING ELEMENTS-IIB-502.1,502.3.1 OBSTRUCTED HIGH SIDE REACH ACI <br />
The URL can be used to link to this page
Your browser does not support the video tag.