Laserfiche WebLink
GAS COCK 0 <br /> GAS PIPE IN CEILING SPACE <br /> A.C.UNIT SUPPORTED PER DETAIL <br /> CEILING FITTINGS LISTED FOR MANUAL GAS VALVE TYP Architecture / Development <br /> UNION PAINT GAS METER, REGULATOR WITH EARTH QUAKE VALVE ON THE RISER AT „ (TYP) P <br /> THE BUILDING AND AT THE METER ALSO, PIPING AND FITTINGS. REFER TO CONCEALED LOCATIONS IN 4 ANCHOR (EYE-SOCKET, STRAP, <br /> 6" DRIP/ NOTES BELOW. CEILING SPACE AND WALLS y--I NIw�4�l�-I^�� OR SIMILAR) 14901 Quorum Drive <br /> DIRT LEG <br /> NOTE: Suite 300 <br /> Ell I <br /> EXHAUST HOOD INSTALL VALVES JUST ABOVE BUILDING STRUCTURE MAY VARY Dallas Texas 75254 <br /> ROOF BY GAS COMPANY (VERIFY) BY CONTRACTOR GAS PIPE HEADER ALONG WALL BEHIND LOCATION PANEL IN ACCESSIBLE MATCH INSTALLATION TO BUILDING Ph: (972)239-8884 <br /> STRUCTURE REFER TO STRUCTURAL Fax: (972)239-5054 <br /> PRESSURE TEST COCK COOKING EQUIPMENT, APPROXIMATELY DRAWINGS FOR ATTACHMENT. COMPLY <br /> 12" ABOVE FLOOR, WITH SCREWED INSTALL AUTOMATIC GAS SHUT-OFF VALVE, WITH MSS-SP-56 AND NFPA-24 ISSUE RECORD <br /> GAS METER - CFH FURNISHED BY FIRE SUPPRESSION COMPANY DATE DESCRIPTION <br /> CAPACITY SHOWN SEISMIC SHUT-OFF FITTINGS, SIZE AS SHOWN ON PLANS. <br /> ON PLANS PROVIDE QUANTITY AND SIZE OF AND INTERCONNECTED TO HOOD FIRE URBAN DESIGN PROTOTYPE <br /> VALVE SV-1 CONNECTIONS AS REQUIRED FOR SUPPRESSION SYSTEM BY F.P.C. 3/8" ALL-THREAD ROD FOR 7-10-2020 ISSUED FOR PERMIT <br /> STRAINER EQUIPMENT BEING SERVED <br /> <=4" PIPE. FOR LARGER PIPE <br /> H <br /> TYPICAL PIPE SUPPORT SIZES SEE NFPA 13. <br /> ANCHORED TO WALL. HANGER - GRINNELL FIG. 69 <br /> SEISMIC SHUT-OFFS G <br /> RTU GAS CONNECTION VALVE "SV-1" GAS (�P)� <br /> MANUAL GAS <br /> GRADE OR VALVE _.-FLEXIBLE APPLIANCE <br /> 05 REGULATOR PAVEMENT BUILDING GRISER T CONNECTOR FURNISHED BY KES <br /> SCALE:NOT TO SCALE FLOOR AND INSTALLED BY CONTRACTOR <br /> SHUT-OFF ZTYPICAL 6" DIRT LEG <br /> TO 6" ABOVE FLOOR ON INSULATED PIPE. PROVIDE <br /> GAS COCK PIPE SUPPORT SHIELD. <br /> VERIFY REQUIREMENTS FOR METERING AND PIPING WITH GAS COMPANY, ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT ACTUAL CONDITIONS. REVISION RECORD <br /> INCLUDING MINIMUM WIDTH & CLEARANCES, IF ANY. CONTRACTOR SHALL PAY INSTALL PIPING HEADER IN WALL CAVITY PROVIDED, SEE ARCHITECTURAL. <br /> ATTACH RISER & HEADER TO WALL WITH 1" CLEARANCE BEHIND PIPE. MAKE 1 10-14 <br /> ALL GAS COMPANY FEES FOR INSTALLATION. FINAL CONNECTION TO EQUIPMENT AS RECOMMENDED BY MANUFACTURER. CIN COOMMEMME <br /> NTS <br /> UNION <br /> EQUIPMENT REMOTE GAS METER DETAIL <br /> 04 <br /> 6" DRIP/ SCALE: NOT TO SCALE GAS APPLIANCE PIPE HANGER DETAIL <br /> DIRT LEG O SCALE:NOT TO SCALE 02 SCALE: NOT TO SCALE <br /> (SEDIMENT TRAP) <br /> SV-1 SEISMIC SHUT-OFF VALVE STRAND EARTHQUAKE COMPANY PH: 310,473,2316 <br /> IAPMO, EXCESS OF CA OSA VALVE MANUFACTURED BY <br /> AND ANSI, LOS ANGELES PACIFIC SEISMIC PRODUCTS INC. <br /> SEDIMENT TRAP DETAIL ORDINANCE #170641-RR VALVE MOD. #314F (4") <br /> 0 SCALE:NOT TO SCALE 5080 LISTED MAX. PRESS. 20-60 PSI. <br /> 10'-0" <br /> ® � 2" (600 CFH) -AL <br /> 4 F SS/p <br /> ®p®0® ®0 <br /> R. <br /> ®�® GAS LOAD SUMMARY FRYERS <br /> 6 W <br /> 2 ® (120 CFH-EA. � No. M29234 m <br /> O3 (TYP OF 5) * Exp. 06/30/21 <br /> 7 (3)GAS GRILLES @ 80,000 BTU/H EA= 240 CFH <br /> P-41 �CHAN�CCA1�F P <br /> 2" MANIFOLD ��P(5)GAS FRYERS @ 120,000 BTU/H EA= 600 CFH P-41 qTF OF <br /> G�' � P-41 SEE NOTE #1 0/14/20 <br /> AC-1 @ 180,000 BTU/H = 180 CFH � <br /> P-41 <br /> \ AC-2 @ 180,000 BTU/H = 180 CFH 2)/2" (680 CFH) P-41 6" DRIP/ DIRT LEG <br /> 1Ya (160 CFH) PROVIDE 24x24 (SEDIMENT TRAP) <br /> ® AC-3 @ 220,000 BTU/H = 220 CFH ACCESS PANEL (TYPICAL) <br /> = G� <br /> O CONNECT VALVE TO HOUSE PIPING. (AN ADDITIONAL STEEL ELBOW BE NECESSARY DEPENDING ONWH-1 2 @ 199,999 BTU/H EA 399.9 CFH oo�P <br /> THE LOCATION OF THE HOUSE PIPING.) �' <br /> T kkr�,,,t M <br /> CONNECT THE MALE END OF THE FITTING TO THE GAS BALL VALVE. TOTAL= 1819.9 CFH �Q vQ F�1 2Y" (840 CFH) <br /> engineering consultants <br /> T CONNECT GAS APPLIANCE CONNECTOR (MALE ADAPTER) TO THE FEMALE END OF THE SWIVEL <br /> FITTING. (NOTE - DO NOT USE PIPE DOPE, TEFLON TAPE OR ANY OTHER SEALING COMPOUND IN �� p GRILLES 14901 Quorum Dr. #565 Dallas, TX 75254 <br /> @ `L (80 CFH—EACH) rtmassociates.com 1 972.387.3500 <br /> 1 X G� <br /> FLARE SEAT OF GAS CONNECTOR.) DISTANCE FROM METER TO MOST REMOTE CONNECTION 180.5' �� �� P „ <br /> ® JOIN FURNISHED STEEL ELBOW TO APPLIANCE NIPPLE. ELBOW SHOULD BE FACING DOWNWARD. MULTIPLIER FOR LOSSES IN SYSTEM (X 1.50) X 1 .50 �pG L 1�� (TYP OF 3) <br /> TOTAL DEVELOPED LENGTH OF SYSTEM � Q�OgP 20.GHAA.027 <br /> O5 ATTACH QUICK DISCONNECT (NIPPLE PORTION) TO STEEL ELBOW. 270.75 <br /> GP`a PROTOTYPE VERSION <br /> © CONNECT BOTH PORTIONS OF QUICK DISCONNECT DEVICE (NIPPLE & COUPLER) TO GAS 7" WATER COLUMN LOW PRESSURE GAS PIPING SYSTEM. ����' (1,020 CFH) 1 76U.2.67 <br /> CONNECTOR. TIGHTEN ALL CONNECTIONS. PERFORM LEAK TEST WITH LEAK TOTAL DEVELOPED LENGTH OF PIPING SYSTEM - 300'-0" <br /> LEAK TEST SOLUTIONS, IMPORTANT: MAY CAUSE CORROSION - WATER RINSE AFTER TEST, THEN - <br /> THOROUGHLY DRY. GAS PIPING SYSTEM SIZED FROM THEPROJECT NAME <br /> O7 RESTRAINING CABLE & MOUNTING HARDWARE: PLUMBING CODE (2019 CPC) TABLE 1215.2(1) X�� �,S 3" (1,419.9 CFH) I N N 0 UT <br /> A: RESTRAINING CABLE LENGTH MUST BE SHORTER THAN GAS CONNECTOR. <br /> B: ATTACH THE STAPLE BRACKET TO A STUD IN THE WALL. 2„ <br /> C: ATTACH EYE-BOLT TO THE EQUIPMENT. BURGER <br /> D: ATTACH SPRING HOOKS OF RESTRAINING CABLE TO EYELET FASTENERS ON WALL AND (399.9 CFH) <br /> EQUIPMENT. <br /> 2" <br /> GAS QUICK DISCONNECT DETAIL <br /> (399.9 CFH) STOCKTON <br /> 07 SCALE:NOT TO SCALE 1 U U CALIFORNIA <br /> 3" (1,599.9 CFH) <br /> TOTAL 1819.9 CFH 1Y4' 5202 PACIFIC AVE <br /> T.D.L. = 175 FT WH-1 (199.999 CFH) STOCKTION, CA 95207 <br /> BASED ON 2019 CPC <br /> G� <br /> NOTE: U U <br /> 1. EXPOSED GAS PIPE BEHIND FRYERS SHALL BE GALVANIZED <br /> STEEL GAS PIPE CONFORMING TO ASTM A 53. VERIFY IF <br /> PERMITTED BY A.H.J. PRIOR TO ORDERING. <br /> N <br /> REMOTE GAS 4" (1,819.9 CFH) qp 2. GAS PIPE WITHIN WALLS AND ABOVE INACCESSIBLE CEILINGS WH-1 <br /> METER SEE SHEET SHALL BE INSTALLED WITH FITTINGS LISTED FOR USE IN <br /> P2.0 FOR "CONCEALED LOCATIONS." INSTALLATION SHALL COMPLY NoNmOUT <br /> CONTINUATION. WITH THE 2019 CPC TABLE 1216.2(1) AND NFPA 54. `BURGERe <br /> 17'-0" N�tk 3. PAINT EXPOSED GAS PIPE ABOVE ROOF BLACK. PAINT GAS GOD BLESS AMERICA <br /> METER AND PIPE EXPOSED TO PUBLIC VIEW WHITE (I.E. <br /> MATCH ADJACENT BUILDING COLOR). <br /> vQ F�1 4. PROVIDE DIRT LEGS AT ROOF EQUIPMENT, GRILLES, WATER <br /> GPc'�O G HEATERS, AND FRYER MANIFOLD. <br /> 6s, Gtk 2 <br /> � PROJECT NUMBER <br /> 190955 <br /> SHEET TITLE <br /> GAS PIPING MATERIALS GAS RISER DIAGRAM GAS RISER <br /> 4" GAS RISER AT A-120 SCHEDULE 40 BLACKSTEEL ASSEMBLED WITH BLACK 01 SCALE: NOT TO SCALE <br /> E BUILDING MALLEABLE 125 LB. FITTING IN SIZES 2" OR SMALLER AND FOR DIAGRAM <br /> LO LARGER SIZES ASSEMBLED BY WELDING FITTING AS MANUFACTURED <br /> O° BY TUBE-TURN. <br /> 0 <br /> N <br /> Z ON , <br /> U <br /> SHEET NUMBER <br /> U <br /> m L;j <br /> Q <br /> D <br /> P6mO <br /> Z Z <br /> d d <br />