Laserfiche WebLink
G-5 VALVE BOX <br />DRAPE TRACER WIRE LOOP <br />8" FROM TOP OF BOX <br />WATER MAIN <br />CONCRETE THRUST <br />BLOCK <br />V24" 18" V �.� � a 24" <br />tl `� FIRE HYDRANT " <br />tl FIRE HYDRANT I 3 FIRE HYDRANT <br />LL <br />f <br />a FACE OF CURB WALK a <br />( <br />0 y 4 q.tl <br />5` WALKLANDSCAPE <br />ACE OF CURB ¢ 10' WALK I <br />p FACE OF CURB <br />NOTES: <br />1, SEE PROJECT SPECS FOR MORE DETAILS. <br />2. FIRE HYDRANTS TO BE AS SHOWN ON CITY STANDARD W -8A OR APPROVED EQUAL & CONFORM TO A.W.W.A. C-503. <br />3. FIRE HYDRANTS SHALL HAVE A 3 FOOT CLEARANCE FROM OBSTRUCTIONS ON ALL SIDES. <br />4. BREAK OFF BOLTS ARE TO BE HOLLOW BOLTS LOCATED THROUGH THE FIRE HYDRANT FLANGE WITH THE BOLTS POINTING DOWN. <br />5, ALL HYDRANTS SHALL BE POSITIONED SUCH THAT THE 2-1/2" DISCHARGES ARE 45 DEGREES, <br />6. ALL HYDRANTS SHALL BE POSITIONED SUCH THAT THE 4-1/2" DISCHARGE IS O DEGREES. <br />APPROVED BY CIVIL ENGINEER: <br />FIRE HYDRANT DRAWING NO, <br />P� / <br />DAN EAVENSON, P.E. MANTECA UNIFIED SCHOOL DISTRICT <br />THRUST BLOCK DIMENSIONS <br />FITTINGS <br />FIRE HYDRANT (MIDST BE INSTALLED LEVEL & PLUMB) <br />I SIDE "B" <br />22-1/2 ® <br />6" & 8" LINE <br />2'-0" <br />21-011 <br />BREAK OFF BOLTS (HOLES DOWN) <br />3' -JO` <br />3'-011 <br />90° <br />6" BREAK OFF SPOOL ABOVE CONCRETE <br />T -('til <br />18" <br />5'-0" SIDEWALK <br />T-V01' <br />2" CLEAR <br />z <br />T -O" <br />DEA END <br />45r(,SI <br />CURB <br />11.5 SF <br />e <br />3.5 SF <br />18T0 24..,. <br />11.5 SF <br />32EE <br />16.5 SF <br />MIN. <br />4,5 SF <br />11.5 SF <br />TRACER VIRE W/ 2" <br />PLATEDvSOLID ' <br />r'00LPABOVEGROUND <br />12" THICK, Tx 3' <br />CLOW RESILIENT - <br />BOLTS <br />CONCRETE PAq <br />yVEDG R MUELER <br />RESILIENT SEAT, OR <br />oEQUAL. <br />GATE VALVE IS <br />6" D.I.P.,,TO <br />BE BOLTED TO TEE. <br />OR P.V.0 <br />6 FLG X MJ GATE <br />VALVE. <br />G-5 VALVE BOX <br />DRAPE TRACER WIRE LOOP <br />8" FROM TOP OF BOX <br />WATER MAIN <br />CONCRETE THRUST <br />BLOCK <br />V24" 18" V �.� � a 24" <br />tl `� FIRE HYDRANT " <br />tl FIRE HYDRANT I 3 FIRE HYDRANT <br />LL <br />f <br />a FACE OF CURB WALK a <br />( <br />0 y 4 q.tl <br />5` WALKLANDSCAPE <br />ACE OF CURB ¢ 10' WALK I <br />p FACE OF CURB <br />NOTES: <br />1, SEE PROJECT SPECS FOR MORE DETAILS. <br />2. FIRE HYDRANTS TO BE AS SHOWN ON CITY STANDARD W -8A OR APPROVED EQUAL & CONFORM TO A.W.W.A. C-503. <br />3. FIRE HYDRANTS SHALL HAVE A 3 FOOT CLEARANCE FROM OBSTRUCTIONS ON ALL SIDES. <br />4. BREAK OFF BOLTS ARE TO BE HOLLOW BOLTS LOCATED THROUGH THE FIRE HYDRANT FLANGE WITH THE BOLTS POINTING DOWN. <br />5, ALL HYDRANTS SHALL BE POSITIONED SUCH THAT THE 2-1/2" DISCHARGES ARE 45 DEGREES, <br />6. ALL HYDRANTS SHALL BE POSITIONED SUCH THAT THE 4-1/2" DISCHARGE IS O DEGREES. <br />APPROVED BY CIVIL ENGINEER: <br />FIRE HYDRANT DRAWING NO, <br />P� / <br />DAN EAVENSON, P.E. MANTECA UNIFIED SCHOOL DISTRICT <br />THRUST BLOCK DIMENSIONS <br />FITTINGS <br />I SIDE "A" <br />I SIDE "B" <br />22-1/2 ® <br />6" & 8" LINE <br />2'-0" <br />21-011 <br />45" <br />3' -JO` <br />3'-011 <br />90° <br />4'-0` <br />T -('til <br />TEE <br />3i_0£! <br />T-V01' <br />DEAD END <br />3'-0t' <br />T -O" <br />sod <br />FITTINGS SIDE <br />FITTINGS I <br />:FAIL <br />,IDEi;Btl <br />b3 <br />22-1/2 <br />BEND <br />10" LINT; <br />4" 15 SF <br />22-1/2 ° <br />31-0" <br />V-0` <br />45' <br />4i-011 <br />41-0t1 <br />90. <br />5'-0` <br />glµnit <br />TEE <br />4:41 <br />3'--611 <br />DEA END <br />45r(,SI <br />31-614 <br />sod <br />FITTINGS SIDE <br />FITTINGS I <br />SIDE -SSIDE <br />"Btl <br />22-1/2 <br />BEND <br />12" LINE <br />4" 15 SF <br />22-1/2 ® <br />31-611 <br />3'4" <br />45` <br />51 011 <br />51-W <br />906 <br />61 0,1 <br />71-4-1 <br />TEE <br />5'-7" <br />Y-711 <br />DEALT ENR <br />4'-10"' <br />4'-10" <br />ANGLE <br />MINIMUM THRUST BLOCK AREAS <br />(IN SQUARE FEET) <br />PIPE SIZE <br />TEE <br />900 <br />BEND <br />45 ° <br />BEND <br />22-1/2 <br />BEND <br />DEAD END . <br />4" 15 SF <br />2 SF <br />1.5 SF <br />1 SF <br />1.5 SF <br />6" 3 SF <br />4.5 SF <br />2.5 SF <br />1.5 SF <br />3 SF I <br />81; 5 SF <br />7 SF <br />4 SF <br />2 SF <br />5 SF I <br />8.5 SF <br />11.5 SF <br />6.5 SF <br />3.5 SF <br />8.5 SF <br />11.5 SF <br />32EE <br />16.5 SF <br />9 SF <br />4,5 SF <br />11.5 SF <br />cu <br />:rn <br />I, 1 IP 9 S . <br />NOTES: <br />I. AREAS ARE FOR 200 POUNDS PER SQUARE INCH WATER PRESSURE AND SANDY TYPE SOILS. <br />2. BLOCKING SHALL BE MADE OF CLASS "B" CONCRETE AND SHALL BE PLACED BETWEEN UNDISTURBED GROUND AND THE FITTING TO BE <br />ANCHORED. THE BLOCKING SHALL BE PLACED SO THAT THE JOINTS OF THE PIPE AND FIT T INGS WILL BE ACCESSIBLE FOR REPAIR, <br />3. THRUST BLOCKS SHALL BE CONSTRUCTED AT PIPE DIAMETER CHANGES AND AT OTHER FITTINGS NOT LISTED, AND SHALL BE PLACED AS <br />DIRECTED BY THE ENGINEER. <br />4, CONCRETE SHALL BE A MINIMUM OF 12" THICK. <br />APPROVED BY CIVIL ENGINEER: (� °�°► BLOCK <br />p� [� <br />THRUST BLOCK SCHEDULE DRAWING NO. <br />FP -2 <br />MANTECA UNIFIED SCHOOL DISTRICT <br />DAN EAVENSON, P.E, , M w <br />DET. A <br />CHAIN (GALVANIZED COATED) AND PADLOCK I <br />(B R EAK-A-WAY) GATE VALVES PER FIRE <br />DEPARTMENT CODE1y4• SQ, I TAMPER <br />PADLOCK I SWITCH <br />RISING STEM <br />6" DIAMETER <br />THERMAL PROTECTION COVER WILKINS MODEL 350 ADA DOUBLE TEMPER SWITCH <br />TO BE APPROVED BY DISTRICT CHECK DETECTOR ASSEMBLY Ea <br />(SEE DET. A) It. <br />PRIOR TO ORDERING \ BODY <br />PADLOCK <br />TAMPER SWITCH 1" SQUARE <br />MIN.)) <br />-RISING STEM STANDPIPE S <br />EXTENSION (7" <br />DUCTILE IRON PIPE � _, _ �. 36" (PAINTED RED) (14" MAX. <br />(TYPICAL) FLANGED ELBOW <br />e 3 pWITH SEPARATE FDC STANDPIPE GROUND LINE MARK <br />SEE DETAIL ABOVE <br />FOR ATTACHED FDC GROUND LINE OR <br />FINISH GRADE MAX. PIPE SUPPORTS -' FINISHED GRADE STANDPIPE <br />MIiV ..._., _. I I STANDPIPE <br />r I ! (PAINTED BLACK) <br />GROUND UNE OR <br />6 FINISHED ADE <br />/ \ CONCRETE GRPAD \,\ 5y8" <br />"95% COMPACTION 30" <br />MINIMUM <br />12 <br />FLOW OUT TO FIRE HYDRANT 5 <br />DIAMETER <br />FLOW N <br />LINE AND/OR POST INDICATOR ASSEMBLY <br />THRUST BLOCK BUILDING F.P. WITH BODY REPROVED <br />SERVICE SEE DET. <br />FP -3 FOR TYPICAL <br />F.P. SETUP)ff <br />TO BUILDING <br />z <br />NOTES: <br />1. REMOVE THE BODY FROM THE TOP OF THE INDICATOR POST ASSEMBLY. <br />2. CUT THE REQUIRED LENGTH OFF THE BOTTOM OF THE STANDPIPE FOR THE GROUND LINE TO MATCH UP WITH THE STANDPIPE GROUND <br />NOTES: LINE MARK. <br />1, SEE PROJECT SPECS FOR MORE DETAILS. 3, CUTTHE 1" SQ, EXTENSION AT A DISTANCE OF 9" ABOVE THE TOP OF THE STANDPIPE. <br />2. CONTACT LOCAL FIRE MARSHAL OR DSA INSPECTOR FOR ALL INSPECTIONS. 4. SET THE "OPEN" AND "CLOSED" TARGETS FOR THE APPROPRIATE VALVE SIZE. <br />3, ALL CONNECTIONS ON ASSEMBLY TO BE FLANGED, 5. RE -ATTACH THE BODY TO THE TOP OF THE INDICATOR POST ASSEMBLY. <br />4. BACKFLOW DEVICE SIZE IS TO BE SAME SIZE AS EXISTING MAIN. 6. ALL POST INDICATOR VALVES SHALL BE INSTALLED WITH AN ELECTRONIC UL LISTED TAMPER SWITCH. <br />5. DISTRICT TO PROVIDE IN-LINE METER IF REQUIRED BY CITY ENGINEER, 7. THERE SHALL BE 36" OF UNOBSTRUCTED CLEARANCE AROUND THE PERIMETER OF ALL POST INDICATOR VALVES. <br />6. ALL ABOVE GROUND PIPING AND FITTINGS SHALL BE COPPER, NO -LEAD BRONZE, OR DUCTILE IRON. S. POST INDICATOR VALVE SHALL BE LOCATED AT A MINIMUM 54T ROM BUILDING. <br />APPROVED BY CIVIL ENGINEER: BACKFLOW P R EVEI! TE R APPROVED BY CIVIL ENGINEER: TA®ARD DOST <br />DRAWING NO. DRAWING NO, <br />FOR FIRE LIKESINDICATOR VALVE FP -5 <br />P-4 <br />DAN EAVENSON, P.E. - CITY ENGINEER MANTECA UNIFIED SCHOOL_ DISTRICT DAN EAVENSON, P.E. - CITY ENGINEER MANTECA UNIFIES? SCHOOL. DISTRICT <br />STANDARD FOR FIRE MUaD PROTECTION SYSTEM <br />rn i2l M nimf-a <br />NOTES: <br />1. FIRE HYDRANTS, ON-STREETAND/OR ON SITE, SHALL BE INSTALLED IN ACCORDANCE WITH CITY STANDARD SPECIFICATIONS. INSPECTION <br />APPROVAL BY FIRE DEPARTMENT AND/OR LOCAL DSA INSPECTOR IS REQUIRED PRIOR TO ANY BACKFILL. <br />2. A MATERIALS INSPECTION IS REQUIRED BEFORE ASSEMBLING UNDERGROUND FIRE PROTECTION SYSTEMS. LOCAL FIRE DEPARTMENT <br />PLAN APPROVAL IS REQUIRED PRIOR TO CONSTRUCTION, <br />3. A PRESSURE TEST AT 200 PSI FOR 2 HOURS WITNESSED BY THE LOCAL FIRE DEPARTMENT IS REQUIRED FOR ALL SYSTEMS. PLEASE NOTE <br />THAT UNDERGROUND FIRE PROTECTION SYSTEM CAN ONLY BE FILLED USING A JUMPER EQUIPPED WITH A BACKFLOW PREVENTION <br />DEVICE ACCORDING TO CITY STANDARDS, PIPE MAY BE CENTER LOADED FOR THIS INSPECTION, HOWEVER, ALL THRUST BLOCKS AND <br />JOINTS MUST BE EXPOSED, PLEASE ALSO NOTE THAT COATING AND WRAPPING OF BOLTS AND TIE RODS, IF REQUIRED, MUST BE <br />COMPLETED BEFORE CALLING FOR AN INSPECTOR. <br />4. A SUCCESSFUL BACTERIAL TEST AND FLUSHING WITNESSED BY THE LOCAL FIRE DEPARTMENT IS REQUIRED BEFORE CONNECTING TO THE <br />PUBLIC MAIN IS PERMITTED. <br />5, SEPARATE SUBMITTALS TO THE MANTECA FIRE DEPARTMENT ARE REQUIRED FOR ABOVE GROUND FIRE PROTECTION SYSTEMS., <br />6. VALVES ON BACKFLOW DEVICES ARE NOT TO BE USED TO SUBSTITUTE FOR VALVES SHOWN ON DIAGRAM. BACKFLOW DEVICE MUST <br />REMAIN IN ORIGINAL CONFIGURATION AS PURCHASED FROM MANUFACTURER. <br />APPROVED BY CIVIL ENGINEER: TYPICAL FIRE <br />DRAWING NO, <br />PROTECTION SET-UP <br />MANTECA UNIFIED SCHOOL DISTRICT <br />DAN EAVENSON, F.E. -CITY ENGINEER <br />4" X 2 1/2- X 2 1/2- BRASS BODY <br />FDC (SINGLE CLAPPER DESIGN) <br />THREADED BRASS j <br />CHECK VALVE L. <br />MIIIN <br />-T L l=� I <br />`I <br />BUILDING T <br />DESIGNATION I <br />6" X 12" ALL WEATHER PLACARD, WHITE <br />WITH BLACK LETTERING (SEE DET. A) <br />TAMPER SWITCH <br />6" INDICATOR POST <br />(SEE DETAIL FP -5) <br />36" <br />MIIN <br />( l FINISHED <br />GRADE <br />j3 <br />=-illI , <br />4" SCH. 40 GALV. E SINGLE CHECK VALVE WILKINS <br />STEEL PIPE i MODEL 310 OR EQUAL <br />VC -90O CL 20d <br />PVC C-900 CL 200-N,, C <br />TO --- I-jP - _ . - , �I tI FLOW <br />BUILDING. <br />€ <br />TEE POST INDICATOR VALVE <br />18' 181, <br />WIN MIIN <br />NOTES: <br />1. SEE PROJECT SPECS FOR MORE DETAILS. <br />2, ALL FIRE LINE MATERIAL SHALL BE APPROVED BY THE LOCAL FIRE MARSHAL PRIOR TO INSTALLATION. <br />3, TAMPER SWITCH SHALL BE INSTALLED ON P€V AND CONDUIT RUN TO BUILDING MECHANICAL ROOM OR OTHERWISE DIRECTED. <br />4. A MINIMUM 12" X 6" WHITE ALL WEATHER PLACARD MUST BE INSTALLED ON FDC WITH BLACK WRITING DENOTING SERVICE LOCATION. <br />6. ALL POST INDICATOR VALVES SHALL BE INSTALLED WITH AN ELECTRONIC UL LISTED TAMPER SWITCH, <br />7.THERE SHALL BE 36" OF UNOBSTRUCTED CLEARANCE AROUND THE PERIMETER OF ALL POST INDICATOR VALVES, <br />8. POST INDICATOR VALVE SHALL BE LOCATED AT A MINIMUM S -FT ROM BUILDING <br />APPROVED BY CIVIL ENGINEER: FIFE DEPARTMENT <br />DRAWING NO. <br />CONNECTIOP /PIV FP-6 <br />EAVENSON, P.E. CITY ENGINEER MANTECA UNIFIED SCHOOL DISTRICT <br />ro <br />W W W mcrEll g LOr% �+ +• <br />OFESSIn <br />iA� l <br />No. C54088 <br />OR 12-31.15 � <br />F DF C�L�� <br />Copyright 0 2014 Rainforth Grau Architects. All rights reserved. Reproduction of these pians, either in whole or in pari, including any form <br />of copying and/or preparation of derivative works thereof, for any reason without prior written permission, is strictly prohibited. <br />DSA <br />File No. 39-53 <br />IDENTIFICATION STAMP <br />DIV. OF THE STATE ARCHITECT <br />02 114490 INC 1 <br />AI / FLS SS <br />DATE t! ® 1 <br />r <br />DRAWN PROJECT" NO. <br />SLS 15-014 <br />CHECKED DATE <br />JDE 6-26-15 <br />SCALE SHEET <br />AS NOTED <br />C3.0.1 <br />