MATERIAL DATA.- <br />(information <br />ATA:(information shown is for structural design reference at new construction only. See <br />the Project Manual for all material specifications.) <br />Concrete ultimate strength: <br />F'c = 3.5 ksi Foundations (Designed for 3 ksi) <br />F'c = 4 ksi Interior Slab on Grade <br />F'c = 4 ksi Walls <br />F'c = 1.5 ksi Lean Mix Fill <br />Masonry: <br />F'm = 1.5 ksi <br />Grout = 2.0 ksi <br />Mortar = 1.3 ksi <br />Reinforcing steel yield strength: <br />Fy = 40 ksi At #3 and smaller <br />Fy = 60 ksi At #4 and larger <br />Steel yield strength (UNO): <br />Fy = 50 ksi W Shapes <br />Fy = 36 ksi plates & Shapes UNO <br />Fy P 50 ksi Plates at Moment Frame Connections <br />Fy = 46 ksi Rectangular HSS <br />Fy = 42 ksi Round HSS <br />Fy e 35 ksi Pipes <br />Fy o 36 ksi Anchor Rods <br />ASTM A325 Bolts <br />Fasteners: <br />Bolts ......... ...................................ASTM A307 <br />Anchor Bolts...............................ASTM F 1554 Grade 36 <br />Cold formed metal framing yield strength: <br />Fy = 33 ksi 13 & 20 gauge <br />Fy = 50 ksi 12,14 & 16 gauge <br />Wood Framing: <br />Posts & Headers DF#1 <br />2x Studs DF#2 <br />Plates & Sills DF#2 <br />LVL (minimum): <br />E = 1.9E3 ksi <br />Fb m2.6ksi <br />Fv = 2.85 psi <br />I -Joists 13" Red -165 by Red -Built <br />(El = 1,205E6 in -lbs) <br />FOUNDATION NOTES: <br />1. <br />ABBREVIATIONS <br />TYPICAL CONCRETE DETAILS <br />ADDNL <br />ADDITIONAL <br />GALV <br />GALVANIZED <br />AB <br />ANCHOR BOLT <br />GC <br />GENERAL CONTRACTOR <br />I ARCH <br />ARCHITECTURAL <br />HA <br />HEADED ANCHOR <br />BTW <br />BETWEEN <br />H <br />HIGH <br />BEV <br />BEVELLED <br />HSB <br />HIGH STRENGTH BOLT <br />BF <br />BRACED FRAME <br />HSS <br />HOLLOW STRUCTURAL STEEL <br />BLKG <br />BLOCKING <br />HORIZ <br />HORIZONTAL <br />BM <br />BEAM <br />LLH <br />LONG LEG HORIZONTAL <br />BOT <br />BOTTOM <br />LLV <br />LONG LEG VERTICAL <br />BRG <br />BEARING <br />MANUF <br />MANUFACTURER <br />CLR <br />CLEAR <br />MAX <br />MAXIMUM <br />CL <br />CENTERLINE <br />MB <br />MACHINE BOLT <br />I OC <br />ON CENTER <br />MECH <br />MECHANICAL <br />CMU <br />CONCRETE MASONRY UNIT <br />MTL <br />METAL <br />CP <br />COMPLETE PENETRATION <br />MF <br />MOMENT FRAME j <br />COL <br />COLUMN <br />MIN <br />MINIMUM <br />CONC <br />CONCRETE <br />NTS <br />NOT TO SCALE <br />' CON STR JT <br />CONSTRUCTION JOINT <br />OC <br />ON CENTER <br />CONT <br />CONTINUOUS <br />OH <br />OPPOSITE HAND <br />CJ <br />CONTROL JOINT, CONTRACTION JOINT OPNG <br />OPENING <br />CTSK <br />COUNTERSUNK <br />PEN <br />PLYWOOD/OSB EDGE NAILING <br />db <br />BAR DIAMETER <br />PL <br />PLATE <br />LTC <br />DEMAND CRITICAL <br />REINF <br />REINFORCING <br />DIA <br />DIAMETER <br />REQ`D <br />REQUIRED <br />DIM <br />DIMENSION <br />REQMT'S <br />REQUIREMENTS <br />DN <br />DOWN <br />(S) <br />SIMPSON STRONG -TIE <br />DO <br />DITTO (REPEAT) <br />SAD <br />SEE ARCHITECTURAL DRAWINGS <br />DS <br />DEPRESSED SLAB <br />SFR S <br />SEISMIC FORCE RESISTING SYSTEM <br />EA <br />EACH <br />SIM <br />SIMILAR <br />EE <br />EACH END <br />SOC <br />SLAB ON GRADE <br />EF <br />EACH FACE <br />SHTG <br />APA RATED SHEATHING <br />EJ <br />EXPANSION JOINT <br />STGR <br />STAGGERED <br />EL (ELEV) <br />ELEVATION <br />STN® HK <br />STANDARD HOOK <br />EN <br />EDGE NAILING <br />STIFF <br />STIFFENER <br />EWEF <br />EACH WAY EACH FACE <br />SQ <br />SQUARE <br />EO <br />EQUAL <br />SYMM <br />SYMMETRICAL <br />EQUIP <br />EQUIPMENT <br />TA <br />THREADED ANCHOR <br />ES <br />EACH SIDE <br />TSB <br />TOP AND BOTTOM <br />EW <br />EACH WAY <br />TOB <br />TOP OF BLOCK <br />FC <br />FACE OF CONCRETE <br />TOC <br />TOP OF CONCRETE <br />FD <br />FLOOR DRAIN <br />TOF <br />TOE' OF FOOTING, TOP OF FRAMING <br />FF <br />FINISHED FLOOR <br />TOS <br />TOP OF STEEL <br />FIN GRD <br />FINISHED GRADE <br />TOW <br />TOP OF WALL <br />FLG <br />FLANGE <br />TYP <br />TYPICAL <br />FOC <br />FACE OF CONCRETE <br />LINO <br />UNLESS NOTED OTHERWISE <br />FOM <br />FACE OF MASONRY <br />VERT <br />VERTICAL <br />FOS <br />FACE OF STUD <br />VIF <br />VERIFY IN FIELD <br />FTG <br />FOOTING <br />W <br />WIDE <br />GA <br />GAGE <br />WP <br />WORKING POINT <br />MATERIAL DATA.- <br />(information <br />ATA:(information shown is for structural design reference at new construction only. See <br />the Project Manual for all material specifications.) <br />Concrete ultimate strength: <br />F'c = 3.5 ksi Foundations (Designed for 3 ksi) <br />F'c = 4 ksi Interior Slab on Grade <br />F'c = 4 ksi Walls <br />F'c = 1.5 ksi Lean Mix Fill <br />Masonry: <br />F'm = 1.5 ksi <br />Grout = 2.0 ksi <br />Mortar = 1.3 ksi <br />Reinforcing steel yield strength: <br />Fy = 40 ksi At #3 and smaller <br />Fy = 60 ksi At #4 and larger <br />Steel yield strength (UNO): <br />Fy = 50 ksi W Shapes <br />Fy = 36 ksi plates & Shapes UNO <br />Fy P 50 ksi Plates at Moment Frame Connections <br />Fy = 46 ksi Rectangular HSS <br />Fy = 42 ksi Round HSS <br />Fy e 35 ksi Pipes <br />Fy o 36 ksi Anchor Rods <br />ASTM A325 Bolts <br />Fasteners: <br />Bolts ......... ...................................ASTM A307 <br />Anchor Bolts...............................ASTM F 1554 Grade 36 <br />Cold formed metal framing yield strength: <br />Fy = 33 ksi 13 & 20 gauge <br />Fy = 50 ksi 12,14 & 16 gauge <br />Wood Framing: <br />Posts & Headers DF#1 <br />2x Studs DF#2 <br />Plates & Sills DF#2 <br />LVL (minimum): <br />E = 1.9E3 ksi <br />Fb m2.6ksi <br />Fv = 2.85 psi <br />I -Joists 13" Red -165 by Red -Built <br />(El = 1,205E6 in -lbs) <br />FOUNDATION NOTES: <br />1. <br />Foundation Design Bearing Pressures: <br />TYPICAL CONCRETE DETAILS <br />Dead + Live = 3000 psf <br />TYPICAL WOOD DETAILS <br />Dead + Lige + Lateral = 4000 psf <br />2. <br />All sails work shall be done in accordance with the specifications, the <br />TYPICAL STEEL & METAL DECKING DETAILS <br />requirements of the Geotechnical Report noted below and Chapter 13A of the <br />FOUNDATION PLAN <br />2413 CBC. All foundations shall bear on firm, undisturbed, native sods or <br />ROOF FLAMING PLANS <br />& ISOMETRICS <br />engineered fill at or exceeding depths shown on the drawings. Engineered fill to <br />FLAMING ELEVATIONS <br />be compacted per Geotechnical report. Increase fill and or footing depth as <br />FOUNDATION DETAILS <br />required by Geotechnical Engineer. All footing excavations shall be as neat as <br />HIGH ROOF DETAILS <br />practicable. Over -excavations in width shall be filled with concrete, and in depth <br />_ <br />ADMIN & CANOPY ROOF DETAILS <br />may be filled with lean concrete or compacted approved backfill. All loose soils <br />LOW ROOF DETAILS_ <br />- - -- <br />.shall be removed from excavations prior to placement of reinforcing or concrete. <br />MISC. ROOF DETAILS .�...__...W...._....._... <br />Geotechnical Report by: <br />Condor Earth Technologies Inc. <br />Project No. 6999E <br />Dated. May 19, 2015 <br />3. <br />Where bottom of adjacent footings are different provide stepped footing per <br />51S1.1. <br />4. <br />Use 5/8" diameter x 12" (13°" at curbs) anchor bolts (AB) at 48"oc where not <br />otherwise noted. Minimum embedment into concrete is 7" (excluding curb) unless <br />detailed otherwise. Anchor bolts are to be tied in place prior to placement of <br />concrete. See shear wall schedule for additional requirements. Minimum: two <br />anchor bolts per sill piece. <br />5. <br />Typical Slab on Grade. 5" concrete reinforced with #4 @ 16"oc each way at mid - <br />depth over, vapor retarder (per specifications) and 4" min of No. 43/4"pea gravel <br />per Geotechnical recommendations and as approved by the Geotechnical <br />Engineer, Do not drive concrete trucks or large screed machines on vapor <br />barrier without additional buffer material and approval from the Structural <br />Engineer. <br />6. <br />Defer to Architectural and Plumbing drawings for depressed slabs for <br />Architectural flooring or inserts, sloped slabs to drain and pipes or conduits at <br />slab. See 8/S1.1 & 9/S1.1 at depressed slab & 7/S1.1 for pipes and conduits. <br />7. <br />Provide control joints (or construction/dowel joints at contractor's option) as <br />shown on plan (10"-0"oc max. UNO) per 6/S1.1. Install joints to divide slab into <br />rectangular areas with long dimension less than 1.5x short dimension. Install <br />joints at face of studs of wall where possible. Submit joint layout plan for review <br />prior to placement. <br />S. <br />Do not undercut existing foundations. Notify Engineer for review and possible <br />revisions, if existing foundation conditions are not as shown. <br />9. <br />Top of footing elevations to be determined by the contractor based on <br />information from the Civil drawings, Geotechnical report, Landscape, etc. <br />LIGHT GAUGE METAL FRAMING NOTES: <br />°I . See plans, details, and Architectural drawings for metal framing locations. See <br />Architectural drawings for wall widths and configurations .AlI framing designations are <br />per Steel Stud Manufactures Assoc.(SSMA) ICC ESR -3064P <br />2. Each products four part identification code identifiers, the size (both depth and flange <br />width) style, and material thickness in ails, example: 600S162-54 <br />660 - Member depth in 1/100" (6") <br />S - Member style - S=Stud, T=Track <br />162 - Flange width in 1/100" (15/8") <br />54 - Material thickness in mils (0.054") <br />MILS EQ. GAUGE <br />33 20 ga <br />43 13 ga <br />54 16 ga <br />63 14 ga <br />97 12 ga <br />3. Typical metal studs and framing are per plans LINO. Submit shop drawings and <br />manufacturer's information showing conformance to criteria shown on drawings and <br />specifications. Minimum metal gauge s 20 (33 mils). <br />4. Typical tracks are 43 mil rain and same as gauge at 54 mil framing. Flange to be <br />1 1/2" min. <br />5. Sheet Metal Screws (MS) or (SMS) to be Pan -Dead or Hex -Head self -drilling or pre- <br />drilled, size as noted on drawings, and of sufficient length to achieve full penetration <br />w/ 3 threads rain projection at all members at connections. Minimum edge distance <br />and spacing is 1" in all members. <br />6. Powder Driven Pins (PDP) in concrete to be X_U universal knurled shank fasteners <br />w/ 0.157" minimum shank diameter and 1 1/4" minimum embedment in concrete. <br />Minimum distance to edge of concrete is 21/2". Minimum spacing to be 4" O.C. DO <br />NOT use PDP at concrete curbs. Install per ICC ESR -2269- <br />7. Powder [given Pins at steel & curtain wall framing clips to be Simpson (S) PDPT <br />Pins with 0.300" O heads dia. & 0.145" O shank dia. Install per mfr & <br />IAPMO ES EIS -236. <br />6. Expansion bolt size and embedment required per drawings & 16/S1.1.1. Minimum <br />edge distance in track is 2" and minimum spacing is 4"'oc UNO. For expansion <br />bolts through metal tracks use 3" square x 1/4" Plate Washer (or equivalent round <br />washer) at track. Drill hole in plate Washer for expansion bolt as needed to achieve <br />minimum edge distances. <br />9. Provide light gauge metal backing for Architectural finishes and furnishings, SAD. <br />INTENT OF DRAWINGS: <br />1. Typical Details and General Notes on these drawings apply to all parts of the <br />project except where specifically detailed or noted otherwise. <br />2. See Project Manual for material specifications. <br />3. Resolve any conflicts on the drawings with the Architects and Structural Engineer <br />before proceeding with construction. Dimensions take precedence over scale of <br />drawings. However, any significant conflicts should be resolved as noted above. <br />4. These drawings represent the finished structure but do not indicate the means or <br />methods or sequences of construction. The contractor is responsible for all <br />temporary bracing, shoring and contractor is responsible for determining and <br />enforcing all construction load limits on the structure. <br />DESIGN CRITERIA: <br />1. Dodoes and Standards: <br />2013 California Building Code (CSC) as adopted by DSA <br />ACI 313611 - ACI Building Code requirements for Structural Concrete <br />AISC 350-10 Specification for Structural Steel Buildings <br />AISC 5100-07 Cold Formed Steel Structural Members <br />ANSI/AWC NDS -2012 for Wood Framing <br />TMS 402-11 Building Code Requirements for Masonry Structures <br />2. Wind Design: <br />Risk Category III <br />Basic Wind Speed V3S =115 MPH Ultimate <br />Exposure Category <br />3. Seismic Desi i7: <br />Disk Category III <br />Design Category D <br />Sail Site Class E <br />Importance Factor, le 1.25 <br />Spectral Response Accelerations <br />Ss = 0.970 g S1 = 0.343 g <br />Sds a 0.6 g Sd1 = 0.6 ­ 5g <br />Analysis Procedure = Equivalent Lateral Force Procedure <br />Response Modification R = 6.50 Light framed walls sheathed with wood struct panels <br />R = 5.00 Special Reinforced Masonry shearwalls <br />R v 5.00 used For Seismic Design of All Lateral Systems <br />Overstrength Factor Do = 2.50 <br />Deflection Amplification C,1 = 3.50 <br />Seismic Coefficient Cs .- 0.151 WW <br />Cs = 0.130 W used for deisgn of All Lateral Systems <br />4. Dead Loads: <br />Nigh Roof = 25 psf (including 5 psf allowance for future solar) <br />Low Roof= 20 psf (including 5 psf allowance for future solar) <br />5. Live Loads: <br />Roof = 20 psf <br />GENERAL NOTES: <br />1. Refer to sheets 41.1, S1.2, S1.3 and S1.4 for standard details of new construction. <br />Defer to the project manual for materials and methods at new construction. <br />2. Building dimensions shown are for general reference only. See Architectural drawings <br />(SAD) for all actual building dimensions. Any discrepancies are to be brought to the <br />attention of the Architect/Engineer so clarification can be made prior to commencing <br />work. All dimensions related to existing conditions shall be verified by the contractor <br />and submitted in writing to the Architect/Engineer for review prior to construction. <br />3. Drawings shall NOT be scaled. All dimensions and fit shall be determined and <br />verified by the contractor prior to commencing work.. <br />4. Details not fully or specifically shown shall be of same nature as other similar <br />conditions. <br />5. Refer to Architectural drawings for sidewalk slabs and dimensions. <br />6. Coordination of mechanical, electrical, plumbing, and site utility systems with the <br />structural system is the responsibility to the General Contractor. Use details 2/S1.1, <br />3/S1.1, and 7/S1.1. At conditions where these details do not appear to apply, notify <br />the Structural Engineer prior to installation. At conditions where field modifications of <br />mechanical, electrical, plumbing, or site utilities affect structural systems, notify <br />Structural Engineer prior to installation. <br />7. Verify weights and locations of mechanical units with Mechanical Engineer prior to <br />placement. units varying over 10% in weight shall be reviewed by the Structural <br />Engineer prior to installation (mechanical weights shown are maximum). Contractor to <br />verify mechanical unit sizes and weights as installed prior to installation of special <br />framing to ensure correct placement under curbs, etc. <br />3. Shoring and bracing design, materials and installation shall be provided by the <br />General Contractor, and shall be adequate for all loads. Leave in place as long as <br />may be required for safety and until final structural construction is completed. <br />9. Special Inspections are required per the DSA approved Testing and Inspection Form <br />103. Structural observation is required for the following unless directed otherwise: <br />- Reinforcing steel <br />- Timber wall & roof framing <br />- Steel roof framing <br />Notify ASG at least 3 days prior to completion of above work. <br />TESTING & INSPECTIONS: <br />1. Per DSA Approved Foran 103 in project manual. <br />S0.1 ___ <br />GENERAL NOTES <br />S1.1 <br />TYPICAL CONCRETE DETAILS <br />S1.2 <br />TYPICAL WOOD DETAILS <br />S1.3 <br />TYPICAL CMU & I -JOIST DETAILS <br />S1.4 <br />TYPICAL STEEL & METAL DECKING DETAILS <br />52.1.1 <br />FOUNDATION PLAN <br />S2.1.2 <br />53.1.1 SECTIONS <br />ROOF FLAMING PLANS <br />& ISOMETRICS <br />53.1.2 <br />FLAMING ELEVATIONS <br />54.1.1 <br />FOUNDATION DETAILS <br />S5.1.1 <br />HIGH ROOF DETAILS <br />55.1.2 <br />_ <br />ADMIN & CANOPY ROOF DETAILS <br />55.1.3 <br />LOW ROOF DETAILS_ <br />- - -- <br />55.1.4 <br />MISC. ROOF DETAILS .�...__...W...._....._... <br />650 University Ave., Suite 110 <br />Sacramento, 0A 95325 <br />Phone: (916) 5149109 <br />ASC Project No. 15015 <br />Copyright 0 20iS Rainforth Grau Architects, All rights reserved. Reproduction of these pians, either in whole or in pari. Including any form <br />of copying and/or preparation of derivative works thereof, for any reason without prior written permission, is strictly prohibited. <br />CASA I SE <br />Fite No. 39-53 <br />IDENTIFICATION STAMP <br />DIV. OF THE STATE ARCHITECT <br />02 -114490 <br />AC_ FLS SS <br />DATE I i. 0/I r - <br />AN1}e�©���c> <br />NO. SE -2911,0 j <br />EXP. 12/37/F�1 <br />OF GA0�� <br />t � t <br />DRAWN <br />Revision TJS <br />CHECKED <br />TGK <br />SCALE <br />As indicated <br />PROJECT NO. <br />15-1207 <br />DATE <br />6-26-15 <br />SHEET <br />SO.1 <br />