1. MECHANICAL AND PLUMBING DETAILS APPLY TO ALL BUILDINGS WHETHER REFERENCED OR NOT. <br />2. PROVIDE FIRE STOPPING ASSEMBLY PROTECTION FOR DUCT PENETRATIONS OF RATED ASSEMBLIES. <br />FIRE STOP RATING SHALL MATCH RATED ASSEMBLY BEING PENETRATED. <br />3. DUCTWORK AND PIPING SHALL NOT PENETRATE INTO OR THROUGH IT CLOSETS OR ELECTRICAL <br />ROOM UNLESS IT SERVES THAT SPECIFIC ROOM. <br />4. REFERENCE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF DIFFUSERS/GRILLES. <br />5. DRAWINGS SHALL BE CONSIDERED DIAGRAMMATIC. THE CONTRACTORS SHALL COORDINATE LOCATION <br />OF ALL MECHANICAL DUCTWORK, EQUIPMENT, AND PIPING WITH ALL OTHER TRADES ON THIS <br />PROJECT. <br />6. CEILING SUPPLY AIR DIFFUSERS TO HAVE 4 --WAY BLOW PATTERN UNLESS SHOWN OTHERWISE. <br />7. THERMOSTATS TO BE INSTALLED AT 46" AFF (TOP OF THERMOSTAT). DO NOT INSTALL <br />THERMOSTATS OVER CASEWORK OR SHELVING OVER 24" IN DEPTH AND 34" IN HEIGHT. <br />ALL MECHANICAL AND PLUMBING COMPONENTS SHALL BE ANCHORED AND INSTALLED PER THE DETAILS ON <br />THE DSA APPROVED CONTRACT DOCUMENTS. WHERE NO DETAIL IS INDICATED, THE FOLLOWING <br />COMPONENTS SHALL BE ANCHORED OR BRACED TO MEET THE FORCE AND DISPLACEMENT` REQUIREMENTS <br />PRESCRIBED IN THE 2013 CBC, SECTION 1616A.1.18 THROUGH 1616A.1.26 AND ASCE 7--10, CHAPTERS IS, <br />16 AND 30. <br />1. ALL PERMANENT EQUIPMENT AND COMPONENTS <br />2. TEMPORARY OR MOVABLE EQUIPMENT THAT IS PERMANENTLY ATTACHED (E.G. HARD WIRED) TO THE <br />BUILDING UTILITY SERVICES SUCH AS ELECTRICITY, GAS, OR WATER. <br />3. MOVABLE EQUIPMENT WHICH IS STATIONED IN ONE PLACE FOR MORE THAN 8 HOURS AND HEAVIER <br />THAN 400 POUNDS ARE REQUIRED TO BE ANCHORED WITH TEMPORARY ATTACHMENTS. <br />THE ATTACHMENT OF THE FOLLOWING MECHANICAL COMPONENTS SHALL BE POSITIVELY ATTACHED TO THE <br />STRUCTURE, BUT NEED NOT BE DETAILED ON THE PLANS. THESE COMPONENTS SHALL HAVE FLEXIBLE <br />CONNECTIONS PROVIDED BETWEEN THE COMPONENT AND ASSOCIATED DUCTWORK, PIPING, AND CONDUIT. <br />A. COMPONENTS WEIGHING LESS THAN 400 POUNDS AND HAVE A CENTER OF MASS LOCATED 4 FEET <br />OR LESS ABOVE THE ADJACENT FLOOR OR ROOF LEVEL THAT DIRECTLY SUPPORT THE <br />COMPONENT. <br />B. COMPONENTS WEIGHING LESS THAN 20 POUNDS, OR IN THE CASE OF DISTRIBUTED SYSTEMS, LESS <br />THAN 5 POUNDS PER FOOT, WHICH ARE SUSPENDED FROM A ROOF OR FLOOR OR HUNG FROM A <br />WALL. <br />FOR THOSE ELEMENTS THAT DO NOT REQUIRE DETAILS ON THE APPROVED DRAWINGS, THE INSTALLATION <br />SHALL BE SUBJECT TO THE APPROVAL OF THE STRUCTURAL ENGINEER OF RECORD AND THE DSA <br />DISTRICT STRUCTURAL ENGINEER, THE PROJECT INSPECTOR WILL VERIFY THAT ALL COMPONENTS AND <br />EQUIPMENT HAVE BEEN ANCHORED IN ACCORDANCE WITH THE ABOVE REQUIREMENTS. <br />PIPING AND, DUCTWORK SYSTEM BRACING NOTE: <br />PIPING AND DUCTWORK SHALL BE BRACED TO COMPLY THE FORCE AND DISPLACEMENTS PRESCRIBED IN <br />ASCE 7-10 SECTION 13.3 AS DEFINED IN ASCE 7-10 SECTION 13.6.6, 13.6.7, AND 13.6.5.6, AND 2013 <br />CBC, SECTIONS 1616A.1.23, 1616A.1.24, 1616A=1.25, AND 1615A.1.26. <br />THE BRACING AND ATTACHMENT TO THE STRUCTURE SHALL BE DETAILED ON THE APPROVED DRAWINGS <br />OR THEY SHALL COMPLY WITH ONE OF THE OSHPD PRE -APPROVALS (OPM #) AS MODIFIED TO SATISFY <br />ANCHORAGE REQUIREMENTS OF AGI 316, APPENDIX D. <br />COPIES OF THE MANUAL SHALL BE AVAILABLE ON THE JOBSITE PRIOR TO THE START OF HANDING AND <br />BRACING OF THE PIPE AND DUCTWORK SYSTEMS. <br />THE STRUCTURAL ENGINEER OF RECORD SHALL VERIFY THE ADEQUACY OF THE STRUCTURE TO SUPPORT <br />THE HANGER AND BRACE LOADS. <br />AIR CONDITIONING <br />EXHAUST <br />FAN <br />SCHEDULE <br />MANUFACTURER & <br />MANUFACTURER & <br />EXTERNAL SP <br />SUPPLY AIR BLOWER <br />HEATING CAPACITY (BTUH) <br />MIM. COOLING CAPACITY MBH <br />ARI CONDITIONS) <br />HEATING CAPACITY (BTUH) <br />MAXIMUM UNIT <br />CONTROL INTERLOCK <br />SCHEDULE <br />SYMBOL <br />MODEL NUMBER <br />TOTAL CFM <br />INCHES W.C.) <br />MOTOR HP <br />MOTOR BHP <br />MOTOR RPM <br />ELECTRICAL <br />WEIGHT <br />(LBS.) <br />AC UNIT <br />LIGHT SWITCH <br />OUTSIDE AIR <br />(CFM) <br />DETECTOR <br />WEIGHT <br />ESP. <br />NOTES <br />NOMINAL <br />DESIGN <br />INTERLOCK <br />INTERLOCK <br />EF <br />GREENHECK <br />1,200 <br />0.375 <br />1/2 <br />0.12 <br />HP <br />1,000 <br />120V/10/60 Hz <br />125 <br />AC/G1 <br />G120 <br />1G <br />MODEL: CUE -161 -VG <br />TOTAL <br />SENSIBLE <br />INPUT <br />OUTPUT <br />PHASE <br />HERTZ <br />VOLTS <br />PHASE <br />HERTZ <br />MOCP <br />EF <br />2G <br />GREENHECK <br />MODEL: CUE -099 -VG <br />425 <br />0.375 <br />1/4 <br />0.05 <br />AC <br />1,725 <br />120V/10/60 Hz <br />100 <br />AC/G2 <br />G116 <br />EF <br />3G <br />GREENHECK <br />MODEL: CUE -099 -VG <br />625 <br />0.375 <br />1/4 <br />0.07 <br />HEATING TO BE 8 STAGES FURNACE CONTROL (MIN.) <br />1,725 <br />120V/10/60 Hz <br />100 <br />AC/G3 <br />G109 <br />EF <br />GREENHECK <br />1,200 <br />0.375 <br />1/2 <br />0.12 <br />25 <br />1,000 <br />120V/10/60 Hz <br />150 <br />MAU/1G <br />NA <br />\4G7 <br />MODEL: CUE -099 -VG <br />STAGE = <br />2ND STAGE = <br />11.20 <br />EER <br />208 <br />30 <br />60 <br />40 <br />SEE NOTE 4 <br />NOT REQUIRED <br />NOTES: <br />COOLING <br />(MIN) COOLING <br />LISTED AT 2ND STAGE. PROVIDE WITH POWER <br />2. UNIT TO BE INTERLOCKED TO KITCHEN HOOD AND EXHAUST FAN <br />1. PROVIDE ROOF MOUNTED EXHAUST FANS WITH <br />MANUFACTURER'S ROOF CURB. <br />3, UNIT TO BE PROVIDED WITH THE FOLLOWING: <br />2. LISTED MAXIMUM UNIT WEIGHT INCLUDES ALL ACCESSORIES (ROOF CURB, BIRDSCREENS, <br />DAMPERS, ETC.). <br />1. MECHANICAL AND PLUMBING DETAILS APPLY TO ALL BUILDINGS WHETHER REFERENCED OR NOT. <br />2. PROVIDE FIRE STOPPING ASSEMBLY PROTECTION FOR DUCT PENETRATIONS OF RATED ASSEMBLIES. <br />FIRE STOP RATING SHALL MATCH RATED ASSEMBLY BEING PENETRATED. <br />3. DUCTWORK AND PIPING SHALL NOT PENETRATE INTO OR THROUGH IT CLOSETS OR ELECTRICAL <br />ROOM UNLESS IT SERVES THAT SPECIFIC ROOM. <br />4. REFERENCE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF DIFFUSERS/GRILLES. <br />5. DRAWINGS SHALL BE CONSIDERED DIAGRAMMATIC. THE CONTRACTORS SHALL COORDINATE LOCATION <br />OF ALL MECHANICAL DUCTWORK, EQUIPMENT, AND PIPING WITH ALL OTHER TRADES ON THIS <br />PROJECT. <br />6. CEILING SUPPLY AIR DIFFUSERS TO HAVE 4 --WAY BLOW PATTERN UNLESS SHOWN OTHERWISE. <br />7. THERMOSTATS TO BE INSTALLED AT 46" AFF (TOP OF THERMOSTAT). DO NOT INSTALL <br />THERMOSTATS OVER CASEWORK OR SHELVING OVER 24" IN DEPTH AND 34" IN HEIGHT. <br />ALL MECHANICAL AND PLUMBING COMPONENTS SHALL BE ANCHORED AND INSTALLED PER THE DETAILS ON <br />THE DSA APPROVED CONTRACT DOCUMENTS. WHERE NO DETAIL IS INDICATED, THE FOLLOWING <br />COMPONENTS SHALL BE ANCHORED OR BRACED TO MEET THE FORCE AND DISPLACEMENT` REQUIREMENTS <br />PRESCRIBED IN THE 2013 CBC, SECTION 1616A.1.18 THROUGH 1616A.1.26 AND ASCE 7--10, CHAPTERS IS, <br />16 AND 30. <br />1. ALL PERMANENT EQUIPMENT AND COMPONENTS <br />2. TEMPORARY OR MOVABLE EQUIPMENT THAT IS PERMANENTLY ATTACHED (E.G. HARD WIRED) TO THE <br />BUILDING UTILITY SERVICES SUCH AS ELECTRICITY, GAS, OR WATER. <br />3. MOVABLE EQUIPMENT WHICH IS STATIONED IN ONE PLACE FOR MORE THAN 8 HOURS AND HEAVIER <br />THAN 400 POUNDS ARE REQUIRED TO BE ANCHORED WITH TEMPORARY ATTACHMENTS. <br />THE ATTACHMENT OF THE FOLLOWING MECHANICAL COMPONENTS SHALL BE POSITIVELY ATTACHED TO THE <br />STRUCTURE, BUT NEED NOT BE DETAILED ON THE PLANS. THESE COMPONENTS SHALL HAVE FLEXIBLE <br />CONNECTIONS PROVIDED BETWEEN THE COMPONENT AND ASSOCIATED DUCTWORK, PIPING, AND CONDUIT. <br />A. COMPONENTS WEIGHING LESS THAN 400 POUNDS AND HAVE A CENTER OF MASS LOCATED 4 FEET <br />OR LESS ABOVE THE ADJACENT FLOOR OR ROOF LEVEL THAT DIRECTLY SUPPORT THE <br />COMPONENT. <br />B. COMPONENTS WEIGHING LESS THAN 20 POUNDS, OR IN THE CASE OF DISTRIBUTED SYSTEMS, LESS <br />THAN 5 POUNDS PER FOOT, WHICH ARE SUSPENDED FROM A ROOF OR FLOOR OR HUNG FROM A <br />WALL. <br />FOR THOSE ELEMENTS THAT DO NOT REQUIRE DETAILS ON THE APPROVED DRAWINGS, THE INSTALLATION <br />SHALL BE SUBJECT TO THE APPROVAL OF THE STRUCTURAL ENGINEER OF RECORD AND THE DSA <br />DISTRICT STRUCTURAL ENGINEER, THE PROJECT INSPECTOR WILL VERIFY THAT ALL COMPONENTS AND <br />EQUIPMENT HAVE BEEN ANCHORED IN ACCORDANCE WITH THE ABOVE REQUIREMENTS. <br />PIPING AND, DUCTWORK SYSTEM BRACING NOTE: <br />PIPING AND DUCTWORK SHALL BE BRACED TO COMPLY THE FORCE AND DISPLACEMENTS PRESCRIBED IN <br />ASCE 7-10 SECTION 13.3 AS DEFINED IN ASCE 7-10 SECTION 13.6.6, 13.6.7, AND 13.6.5.6, AND 2013 <br />CBC, SECTIONS 1616A.1.23, 1616A.1.24, 1616A=1.25, AND 1615A.1.26. <br />THE BRACING AND ATTACHMENT TO THE STRUCTURE SHALL BE DETAILED ON THE APPROVED DRAWINGS <br />OR THEY SHALL COMPLY WITH ONE OF THE OSHPD PRE -APPROVALS (OPM #) AS MODIFIED TO SATISFY <br />ANCHORAGE REQUIREMENTS OF AGI 316, APPENDIX D. <br />COPIES OF THE MANUAL SHALL BE AVAILABLE ON THE JOBSITE PRIOR TO THE START OF HANDING AND <br />BRACING OF THE PIPE AND DUCTWORK SYSTEMS. <br />THE STRUCTURAL ENGINEER OF RECORD SHALL VERIFY THE ADEQUACY OF THE STRUCTURE TO SUPPORT <br />THE HANGER AND BRACE LOADS. <br />ITEM TO BE REMOVED / DEMOED <br />RETURN OR EXHAUST AIR DUCT <br />SUPPLY AIR DUCT <br />FLEXIBLE CONNECTION <br />------- - �� BLV BALL VALVE <br />BV. BALANCE VALVE <br />BFV BUTTERFLY VALVE <br />---+�- CKV. CHECK VALVE <br />THERMOMETER, PRESSURE GAUGE <br />-;�-- OUTSIDE AIR INTO LOUVER <br />-r---- RETURN OR EXHAUST AIR INTO REGISTER <br />SUPPLY AIR FROM REGISTER <br />EXHAUST AIR DUCT SECTION <br />RETURN AIR DUCT SECTION <br />SUPPLY AIR DUCT SECTION <br />12 x 10 DUCT FIRST FIGURE 510E SHOWN <br />SECON FIGURE SIDE NOT SHOWN) <br />SQUARE TO ROUND TRANSITION <br />fF� TURNING VANES <br />--� FLEXIBLE DUCTWORK <br />VCD VCD <br />---�-' VOLUME CONTROL DAMPER <br />R _ D_ <br />RISE OR DROP IN DIRECTION OF ARROW <br />SUPPLY AIR GRILLE ID ZE <br />CFM <br />RETURN AIR GRILLE ID -I -E-- <br />FM <br />EXHAUST AIR GRILLE ID <br />.. !. <br />' rainarchitects <br />forth <br />ROOM THERMOSTAT (SEE MECHANICAL NOTES <br />FOR MOUNTING HEIGHT) <br />Yom' DIAMETER <br />AC AIR CONDITIONING <br />AD, AP ACCESS DOOR, ACCESS PANEL <br />CC CENTER TO CENTER <br />CFM,f CUBIC FEET OF AIR PER MINUTE <br />(E), (N) EXISTING, NEW <br />EA EXHAUST AIR <br />EAD EXHAUST AIR DAMPER <br />EF EXHAUST FAN <br />`F DEGREES FAHRENHEIT <br />FA / FB FROM ABOVE / FROM BELOW <br />FD / FSD FIRE DAMPER / FIRE SMOKE DAMPER >; <br />GA. GAUGE =' <br />GALV. GALVANIZED <br />ESTON <br />GPM GALLONS PER MINUTE ASSOCIATES <br />HP / 6HP HORSEPOWER / BREAK HORSEPOWER <br />MAX., MIN. MAXIMUM, MINIMUM <br />MECHANICAL ENGINEERS <br />M.D. MANUAL DAMPER 4701 ANNE WAY k CARMICHAEL, CA 95608 1 (91 b) 4€ 2-0820 <br />NA NOT APPLICABLE WESTON & ASSOCIATES #15012 <br />NTS NOT TO SCALE <br />pFESS�G� <br />PRV. PRESSURE REDUCING VALVE e ®® A, pit E -le <br />OA OUTSIDE AIR.y <br />c� � No. M312 a u <br />OAD OUTSIDE AIR DAMPER ' <br />IRA RETURN AIR <br />RENEWAL DATE: <br />RAO RETURN AIR DAMPER v�'� v31t2015C�_- <br />flA N <br />RF RELIEF FAN <br />SMS SHEET METAL SCREW <br />SA, OA, SUPPLY AIR, OUTSIDE AIR <br />TA / T8 TO ABOVE / TO BELOW <br />T.C.V. TEMPERATURE CONTROL VALVE <br />T.C.P. TEMPERATURE CONTROL PANEL <br />TYP. TYPICAL <br />$ ON/OFF SWITCH / STARTER <br />ROOM NAME ROOM NAME AND NUMBER <br />0 <br />ALL WORK PERFORMED UNDER THIS CONTRACT IS TO CONFIRM TO THE FOLLOWING <br />CODES AND REGULATIONS: <br />1. CALIFORNIA ADMINISTRATIVE CODE, 2013 <br />2. CALIFORNIA BUILDING CODE, 2013 <br />3. CALIFORNIA MECHANICAL CODE, 2013 <br />4. CALIFORNIA PLUMBING CODE, 2013 <br />5. CALIFORNIA FIRE CODE, 2013 <br />6. CALIFORNIA ELECTRICAL. CODE, 2013 <br />7. CALIFORNIA ENERGY CODE, 2013 <br />THE ABOVE CODES AND REGULATIONS REFER TO THE LATEST EDITION OR REVISION IF <br />FORCE ON THE DATE OF THE CONTRACT, UNLESS OTHERWISE STATED. NOTHING ON <br />THE DRAWINGS IS TO BE CONSTRUED AS REQUIRING OR PERMITTING WORK THAT IS <br />CONTRARY TO THE LISTED CODES AND REGULATIONS, OR OTHER LOCAL, STATE OR <br />FEDERAL CODES OR REGULATIONS WHICH MAY BE APPLICABLE. <br />Copyright Q 2014 Rainforth Grau Architects. All rights reserved. Reproduction of ftse plans, either In whole or In part, Intruding any form <br />of copying andfor proration of derlvaM works toed, for any reason vA#*ut prior wri ten permission, is Wcdy prol•rltaited, <br />mu <br />File tela.: 39-53 <br />IDENTIFICATION STAMP <br />DIV. OF THE STATE ARCHITECT <br />02-114490 INC. 1 <br />AC r' FLSSS <br />DATE i 1/ D )/jS- <br />pr <br />r::.� <br />INCREMENT <br />CAFETERIA <br />MANTECAUNIFIED SCHOOL <br />VIANTECA, CALIFORNIA <br />MECHANICAL - <br />LEGEND, SCHEDULES, AND NOTE] <br />DRAW 4 DW PROJECT NO- <br />CHECKED DATE <br />DW <br />SCALE SHEET <br />15-1207 <br />06-26-15 <br />AIR CONDITIONING <br />UNIT SCHEDULE <br />MADE-UP Alm"UNIT <br />SCHEDULE <br />SUPPLY AIR BLOWER <br />MANUFACTURER & <br />NOMINAL <br />SUPPLY AIR BLOWER <br />HEATING CAPACITY (BTUH) <br />MIM. COOLING CAPACITY MBH <br />ARI CONDITIONS) <br />HEATING CAPACITY (BTUH) <br />MINIMUM <br />SYMBOL <br />UNIT ELECTRICAL DATA <br />MINIMUM <br />DUCT SMOKE <br />MAXIMUM <br />UNIT <br />SYMBOL <br />MODEL NUMBER <br />TONAGE <br />EER / <br />SEER <br />OUTSIDE AIR <br />(CFM) <br />DETECTOR <br />WEIGHT <br />ESP. <br />NOTES <br />NOMINAL <br />DESIGN <br />FLA <br />FLA <br />FLA <br />HP <br />hHP <br />TSP <br />CFM <br />MAXIMUM CFM <br />bHP <br />ESP <br />LD8 <br />TOTAL <br />SENSIBLE <br />INPUT <br />OUTPUT <br />PHASE <br />HERTZ <br />VOLTS <br />PHASE <br />HERTZ <br />MOCP <br />GREENHECK <br />MODEL. IG -109-H12 <br />1,200 <br />(LBS.) <br />0.28 <br />0.5 <br />0.65 <br />MIN. <br />AC <br />CARRIER <br />CARRIER WEATHEREXPERT <br />WEATHEREXPERT <br />79F <br />71'F <br />100,000 <br />80,000 <br />120 <br />10 <br />60 <br />48 <br />1ST STAGE = 248 <br />1ST2ND <br />IST STAGE = 200 <br />00 <br />HEATING TO BE 8 STAGES FURNACE CONTROL (MIN.) <br />27 <br />PROVIDE WITH MEDIUM STATIC DRIVE UNIT TO HAVE 2 STAGES OF <br />1G <br />MODEL: 2r3 <br />25 <br />10,000 <br />10,000 <br />5.94 <br />1.2 <br />305,9 <br />231.8 <br />STAGE = <br />2ND STAGE = <br />11.20 <br />EER <br />208 <br />30 <br />60 <br />40 <br />SEE NOTE 4 <br />NOT REQUIRED <br />3,500 <br />COOLING <br />(MIN) COOLING <br />LISTED AT 2ND STAGE. PROVIDE WITH POWER <br />2. UNIT TO BE INTERLOCKED TO KITCHEN HOOD AND EXHAUST FAN <br />EF/4G, UNIT <br />TO OPERATE WHENEVER EF/4G IS ENABLED. <br />3, UNIT TO BE PROVIDED WITH THE FOLLOWING: <br />EXHAUST <br />- SEE NOTE 5 <br />FOR DETAILS <br />AC <br />CARRIER WEATHEREXPERT <br />7.5 <br />3,000 <br />1.40 <br />91.0 <br />0.80 <br />91.0 <br />84,4 <br />1 ST STAGE= 1200 <br />1ST STAGE -_98 <br />13.0 <br />EER <br />208 <br />310 <br />60 <br />36 <br />500 <br />REQUIRED <br />2,000 <br />PROVIDE <br />UNIT TO <br />WITH MEDIUM STATIC DRIVE <br />HAVE 3 STAGES OF COOLING (MIN) <br />2G <br />MODEL: 48LCD-008 <br />FILTERS, AND <br />RECIRCULATING PUMP, <br />4. PROVIDE UNIT WITH A VENTSTAR MODEL T8850 PROGRAMMABLE THERMOSTAT. <br />2ND STAGE=150 <br />2ND STAGE=120 <br />45 <br />COOLING <br />LISTED AT 3RD <br />STAGE <br />AC <br />3G <br />CARRIER WEATHEREXPERT <br />MODEL: 48LCD-005 <br />4 <br />1,600 <br />1,600 <br />0.95 <br />0.80 <br />4.9.1 <br />366 <br />IST STAGE=50.0 <br />2ND STAGE=72.0 <br />1ST STAGE=41.0 <br />2ND STAGE=56.0 <br />16.4 <br />SEER <br />208 <br />30 <br />60 <br />27 <br />40 <br />625 <br />NOT REQUIRED <br />1,200 <br />UNIT TO <br />COOLING <br />HAVE 2 STAGES <br />LISTED AT 2ND <br />OF COOLING (MIN) <br />STAGE <br />NOTES: <br />1. SCHEDULED COOLING CAPACITIES ARE LISTED AT NOMINAL CFM (400 CFM/TON) <br />AT ARI CONDITIONS - 95-F AMBIENT, 80-F DB <br />/' 67°F WB. REFERENCE FLOORPLANS FOR <br />ACTUAL DESIGN CFM AND BALANCE ACCORDINGLY. <br />2. PROVIDE ALL UNITS WITH THE FOLLOWING MANUFACTURER'S FACTORY INSTALLED <br />OPTIONS <br />/ ACCESSORIES: <br />- HINGED ACCESS PANELS <br />- COIL GUARDS <br />- 2" PLEATED FILTERS (MERV 13 FILTERS) <br />- TXV VALVE <br />- 0-1009 ENTHALPY ECONOMIZER WITH BAROMETRIC RELIEF. PROVIDE WITH <br />JADE T24 <br />COMPLIANT CONTROLLER. <br />- CARRIER COMFORTLINK CONTROLS <br />3. PROVIDE EACH UNIT WITH A VENTSTAR MODEL T8850 PROGRAMMABLE THERMOSTAT. <br />4. AC/1G MINIMUM OUTSIDE AIR TO BE 1,200 WHEN CO2 IS SATISFIED. MINIMUM <br />OUTSIDE <br />AIR WHEN CO2 IS NOT SATISFIED TO BE 3,000 CFM <br />5. AC UNIT AC/IG TO BE PROVIDED WITH MICROMETAL PCD--HE34F-2MH POWER EXHAUST. <br />POWER EXHAUST TO BE 23OV/30, <br />MODULATING EXHAUST, EQUIPED WITH TWO 3 <br />HP MOTORS AND CAPABLE OF EXHAUSTING 9,900 CFM AT 2" WC. POWER EXHAUST FLA = 17.6 <br />ITEM TO BE REMOVED / DEMOED <br />RETURN OR EXHAUST AIR DUCT <br />SUPPLY AIR DUCT <br />FLEXIBLE CONNECTION <br />------- - �� BLV BALL VALVE <br />BV. BALANCE VALVE <br />BFV BUTTERFLY VALVE <br />---+�- CKV. CHECK VALVE <br />THERMOMETER, PRESSURE GAUGE <br />-;�-- OUTSIDE AIR INTO LOUVER <br />-r---- RETURN OR EXHAUST AIR INTO REGISTER <br />SUPPLY AIR FROM REGISTER <br />EXHAUST AIR DUCT SECTION <br />RETURN AIR DUCT SECTION <br />SUPPLY AIR DUCT SECTION <br />12 x 10 DUCT FIRST FIGURE 510E SHOWN <br />SECON FIGURE SIDE NOT SHOWN) <br />SQUARE TO ROUND TRANSITION <br />fF� TURNING VANES <br />--� FLEXIBLE DUCTWORK <br />VCD VCD <br />---�-' VOLUME CONTROL DAMPER <br />R _ D_ <br />RISE OR DROP IN DIRECTION OF ARROW <br />SUPPLY AIR GRILLE ID ZE <br />CFM <br />RETURN AIR GRILLE ID -I -E-- <br />FM <br />EXHAUST AIR GRILLE ID <br />.. !. <br />' rainarchitects <br />forth <br />ROOM THERMOSTAT (SEE MECHANICAL NOTES <br />FOR MOUNTING HEIGHT) <br />Yom' DIAMETER <br />AC AIR CONDITIONING <br />AD, AP ACCESS DOOR, ACCESS PANEL <br />CC CENTER TO CENTER <br />CFM,f CUBIC FEET OF AIR PER MINUTE <br />(E), (N) EXISTING, NEW <br />EA EXHAUST AIR <br />EAD EXHAUST AIR DAMPER <br />EF EXHAUST FAN <br />`F DEGREES FAHRENHEIT <br />FA / FB FROM ABOVE / FROM BELOW <br />FD / FSD FIRE DAMPER / FIRE SMOKE DAMPER >; <br />GA. GAUGE =' <br />GALV. GALVANIZED <br />ESTON <br />GPM GALLONS PER MINUTE ASSOCIATES <br />HP / 6HP HORSEPOWER / BREAK HORSEPOWER <br />MAX., MIN. MAXIMUM, MINIMUM <br />MECHANICAL ENGINEERS <br />M.D. MANUAL DAMPER 4701 ANNE WAY k CARMICHAEL, CA 95608 1 (91 b) 4€ 2-0820 <br />NA NOT APPLICABLE WESTON & ASSOCIATES #15012 <br />NTS NOT TO SCALE <br />pFESS�G� <br />PRV. PRESSURE REDUCING VALVE e ®® A, pit E -le <br />OA OUTSIDE AIR.y <br />c� � No. M312 a u <br />OAD OUTSIDE AIR DAMPER ' <br />IRA RETURN AIR <br />RENEWAL DATE: <br />RAO RETURN AIR DAMPER v�'� v31t2015C�_- <br />flA N <br />RF RELIEF FAN <br />SMS SHEET METAL SCREW <br />SA, OA, SUPPLY AIR, OUTSIDE AIR <br />TA / T8 TO ABOVE / TO BELOW <br />T.C.V. TEMPERATURE CONTROL VALVE <br />T.C.P. TEMPERATURE CONTROL PANEL <br />TYP. TYPICAL <br />$ ON/OFF SWITCH / STARTER <br />ROOM NAME ROOM NAME AND NUMBER <br />0 <br />ALL WORK PERFORMED UNDER THIS CONTRACT IS TO CONFIRM TO THE FOLLOWING <br />CODES AND REGULATIONS: <br />1. CALIFORNIA ADMINISTRATIVE CODE, 2013 <br />2. CALIFORNIA BUILDING CODE, 2013 <br />3. CALIFORNIA MECHANICAL CODE, 2013 <br />4. CALIFORNIA PLUMBING CODE, 2013 <br />5. CALIFORNIA FIRE CODE, 2013 <br />6. CALIFORNIA ELECTRICAL. CODE, 2013 <br />7. CALIFORNIA ENERGY CODE, 2013 <br />THE ABOVE CODES AND REGULATIONS REFER TO THE LATEST EDITION OR REVISION IF <br />FORCE ON THE DATE OF THE CONTRACT, UNLESS OTHERWISE STATED. NOTHING ON <br />THE DRAWINGS IS TO BE CONSTRUED AS REQUIRING OR PERMITTING WORK THAT IS <br />CONTRARY TO THE LISTED CODES AND REGULATIONS, OR OTHER LOCAL, STATE OR <br />FEDERAL CODES OR REGULATIONS WHICH MAY BE APPLICABLE. <br />Copyright Q 2014 Rainforth Grau Architects. All rights reserved. Reproduction of ftse plans, either In whole or In part, Intruding any form <br />of copying andfor proration of derlvaM works toed, for any reason vA#*ut prior wri ten permission, is Wcdy prol•rltaited, <br />mu <br />File tela.: 39-53 <br />IDENTIFICATION STAMP <br />DIV. OF THE STATE ARCHITECT <br />02-114490 INC. 1 <br />AC r' FLSSS <br />DATE i 1/ D )/jS- <br />pr <br />r::.� <br />INCREMENT <br />CAFETERIA <br />MANTECAUNIFIED SCHOOL <br />VIANTECA, CALIFORNIA <br />MECHANICAL - <br />LEGEND, SCHEDULES, AND NOTE] <br />DRAW 4 DW PROJECT NO- <br />CHECKED DATE <br />DW <br />SCALE SHEET <br />15-1207 <br />06-26-15 <br />MADE-UP Alm"UNIT <br />SCHEDULE <br />SUPPLY AIR BLOWER <br />EVAPORATIVE COOLING <br />HEATING CAPACITY (BTUH) <br />UNIT ELECTRICAL DATA <br />MAXIMUM <br />SYMBOL <br />MANUFACTURER & <br />MODEL NUMBER <br />UNIT <br />WEIGHT <br />NOTES <br />ESP. <br />FLA <br />FLA <br />DESIGN CFM <br />HP <br />hHP <br />TSP <br />MIN. <br />MBIA <br />EDS <br />EWB <br />LD8 <br />INPUT <br />OUTPUT <br />VOLTS <br />PHASE <br />HERTZ <br />(LBS.) <br />MAU <br />1 G <br />GREENHECK <br />MODEL. IG -109-H12 <br />1,200 <br />1/3 <br />0.28 <br />0.5 <br />0.65 <br />MIN. <br />MBH <br />97'F <br />79F <br />71'F <br />100,000 <br />80,000 <br />120 <br />10 <br />60 <br />16.5 <br />20 <br />1,200 <br />HEATING TO BE 8 STAGES FURNACE CONTROL (MIN.) <br />NOTES: <br />1. PROVIDE UNIT WITH 2" MERV 8 PLEATED FILTERS <br />2. UNIT TO BE INTERLOCKED TO KITCHEN HOOD AND EXHAUST FAN <br />EF/4G, UNIT <br />TO OPERATE WHENEVER EF/4G IS ENABLED. <br />3, UNIT TO BE PROVIDED WITH THE FOLLOWING: <br />- ROOF CURB AND PEDESTAL MOUNT <br />- HINGED ACCESS PANELS <br />- PLEATED FILTERS (MERV 8 FILTERS) <br />- EVAPORATIVE COOLING WITH CELDEK MEDIA, 2" ALUM. MESH <br />FILTERS, AND <br />RECIRCULATING PUMP, <br />4. PROVIDE UNIT WITH A VENTSTAR MODEL T8850 PROGRAMMABLE THERMOSTAT. <br />ITEM TO BE REMOVED / DEMOED <br />RETURN OR EXHAUST AIR DUCT <br />SUPPLY AIR DUCT <br />FLEXIBLE CONNECTION <br />------- - �� BLV BALL VALVE <br />BV. BALANCE VALVE <br />BFV BUTTERFLY VALVE <br />---+�- CKV. CHECK VALVE <br />THERMOMETER, PRESSURE GAUGE <br />-;�-- OUTSIDE AIR INTO LOUVER <br />-r---- RETURN OR EXHAUST AIR INTO REGISTER <br />SUPPLY AIR FROM REGISTER <br />EXHAUST AIR DUCT SECTION <br />RETURN AIR DUCT SECTION <br />SUPPLY AIR DUCT SECTION <br />12 x 10 DUCT FIRST FIGURE 510E SHOWN <br />SECON FIGURE SIDE NOT SHOWN) <br />SQUARE TO ROUND TRANSITION <br />fF� TURNING VANES <br />--� FLEXIBLE DUCTWORK <br />VCD VCD <br />---�-' VOLUME CONTROL DAMPER <br />R _ D_ <br />RISE OR DROP IN DIRECTION OF ARROW <br />SUPPLY AIR GRILLE ID ZE <br />CFM <br />RETURN AIR GRILLE ID -I -E-- <br />FM <br />EXHAUST AIR GRILLE ID <br />.. !. <br />' rainarchitects <br />forth <br />ROOM THERMOSTAT (SEE MECHANICAL NOTES <br />FOR MOUNTING HEIGHT) <br />Yom' DIAMETER <br />AC AIR CONDITIONING <br />AD, AP ACCESS DOOR, ACCESS PANEL <br />CC CENTER TO CENTER <br />CFM,f CUBIC FEET OF AIR PER MINUTE <br />(E), (N) EXISTING, NEW <br />EA EXHAUST AIR <br />EAD EXHAUST AIR DAMPER <br />EF EXHAUST FAN <br />`F DEGREES FAHRENHEIT <br />FA / FB FROM ABOVE / FROM BELOW <br />FD / FSD FIRE DAMPER / FIRE SMOKE DAMPER >; <br />GA. GAUGE =' <br />GALV. GALVANIZED <br />ESTON <br />GPM GALLONS PER MINUTE ASSOCIATES <br />HP / 6HP HORSEPOWER / BREAK HORSEPOWER <br />MAX., MIN. MAXIMUM, MINIMUM <br />MECHANICAL ENGINEERS <br />M.D. MANUAL DAMPER 4701 ANNE WAY k CARMICHAEL, CA 95608 1 (91 b) 4€ 2-0820 <br />NA NOT APPLICABLE WESTON & ASSOCIATES #15012 <br />NTS NOT TO SCALE <br />pFESS�G� <br />PRV. PRESSURE REDUCING VALVE e ®® A, pit E -le <br />OA OUTSIDE AIR.y <br />c� � No. M312 a u <br />OAD OUTSIDE AIR DAMPER ' <br />IRA RETURN AIR <br />RENEWAL DATE: <br />RAO RETURN AIR DAMPER v�'� v31t2015C�_- <br />flA N <br />RF RELIEF FAN <br />SMS SHEET METAL SCREW <br />SA, OA, SUPPLY AIR, OUTSIDE AIR <br />TA / T8 TO ABOVE / TO BELOW <br />T.C.V. TEMPERATURE CONTROL VALVE <br />T.C.P. TEMPERATURE CONTROL PANEL <br />TYP. TYPICAL <br />$ ON/OFF SWITCH / STARTER <br />ROOM NAME ROOM NAME AND NUMBER <br />0 <br />ALL WORK PERFORMED UNDER THIS CONTRACT IS TO CONFIRM TO THE FOLLOWING <br />CODES AND REGULATIONS: <br />1. CALIFORNIA ADMINISTRATIVE CODE, 2013 <br />2. CALIFORNIA BUILDING CODE, 2013 <br />3. CALIFORNIA MECHANICAL CODE, 2013 <br />4. CALIFORNIA PLUMBING CODE, 2013 <br />5. CALIFORNIA FIRE CODE, 2013 <br />6. CALIFORNIA ELECTRICAL. CODE, 2013 <br />7. CALIFORNIA ENERGY CODE, 2013 <br />THE ABOVE CODES AND REGULATIONS REFER TO THE LATEST EDITION OR REVISION IF <br />FORCE ON THE DATE OF THE CONTRACT, UNLESS OTHERWISE STATED. NOTHING ON <br />THE DRAWINGS IS TO BE CONSTRUED AS REQUIRING OR PERMITTING WORK THAT IS <br />CONTRARY TO THE LISTED CODES AND REGULATIONS, OR OTHER LOCAL, STATE OR <br />FEDERAL CODES OR REGULATIONS WHICH MAY BE APPLICABLE. <br />Copyright Q 2014 Rainforth Grau Architects. All rights reserved. Reproduction of ftse plans, either In whole or In part, Intruding any form <br />of copying andfor proration of derlvaM works toed, for any reason vA#*ut prior wri ten permission, is Wcdy prol•rltaited, <br />mu <br />File tela.: 39-53 <br />IDENTIFICATION STAMP <br />DIV. OF THE STATE ARCHITECT <br />02-114490 INC. 1 <br />AC r' FLSSS <br />DATE i 1/ D )/jS- <br />pr <br />r::.� <br />INCREMENT <br />CAFETERIA <br />MANTECAUNIFIED SCHOOL <br />VIANTECA, CALIFORNIA <br />MECHANICAL - <br />LEGEND, SCHEDULES, AND NOTE] <br />DRAW 4 DW PROJECT NO- <br />CHECKED DATE <br />DW <br />SCALE SHEET <br />15-1207 <br />06-26-15 <br />