NTS <br />4 14" ACCESS PANEL <br />Ic <br />---- DRAIN LINE <br />I � <br />.,„.--------- -- FIXED AIR GAP, "SMITH" 3955 <br />14- 1" AIR GAP (MIN,) <br />1 1/2" VR. <br />CONNECT TO 2" WASTE <br />DROP AS INDICATED ON <br />PLUMBING FLOOR PIANS <br />FLOOR 15" 2" WASTE DROP <br />1 <br />El a' <br />SINK AND/OR LAVATORY <br />TAIL PIECE WITH INDIRECT DRAIN <br />CONNECTION, "SIOUX CHIEF <br />M <br />FR." MODEL 200-066• <br />/�p�/�)]+��1.[yyY lay'. { j 1Pa <br />P -TRAP <br />WALL. CLEANOUT <br />r <br />NTS <br />2" DRAIN WITH CAST IRON P -TRAP <br />3/4" CONDENSATE DROP <br />DRAIN FROM FAN COIL UNIT - <br />VENT <br />3/4" COPPER PIPE, SPRAY PAINT TO <br />MATCH CHROME PLATED CAST TUBE. <br />EXTEND CONDENSATE DRAIN THRU <br />WALL AND CONNECT TO TAIL <br />PIECE INDIRECT BRANCH. <br />ESCUTCHEON <br />WASTE DROP <br />REDUCED PRESSURE BACKFLOW PREVENTION <br />UNIT (RPBP), "WATTS" MODEL 009A QT. <br />CONNECT TO PIPING AS REQUIRED. <br />STUD WALL I <br />CW LINE <br />1/2" <br />1/2" BALL VALVE, p <br />ACCESS PANEL LO <br />TRAP PRIMER ! <br />PROVIDE MANIFOLD AND I <br />MULTIPLE LINES & FUNNELS <br />WHERE. TRAP PRIMER I <br />SERVES MULTIPLE DRAINS I UNION <br />t � <br />1/2" CW DROP <br />SEAL PENETRATION I <br />WATER TIGHT <br />FINISHED FLOOR <br />FLOOR DRAIN OR SINK <br />e <br />C�" I <br />• ,� , Q <br />4 <br />4 - a <br />1/2" CW TO TRAP, <br />CONNECT AS REQUIRED. <br />PROVIDE SLEEVE 1 " <br />CLEAR AROUND PIPE <br />OPEN TRENCH. <br />I � IN11� i111� �111t�=-� <br />PIPE, <br />,9"MIN. <br />FOR CASES OF LESS <br />6„MIN. 1 THAN 3'--0” OTHER- <br />WISE USE STEPPED <br />CONCRETE & SLEEVE I I! FOOTING. <br />FULL WIDTH, 9" OF NOT LESS NOT LESS SLOPE NOT MORE <br />CONCRETE ADJACENT AN 18" THAN 18" THAN 1 IN 2. PIPE <br />TO EITHER SIDE OF MUST NOT BE PLACED <br />SLEEVE, BELOW THIS LINE <br />RE' AT ON OF FIFES & TRENCHES TO FOUNDATIONS <br />NTS <br />SUPERSTRUT MODEL C -708-U <br />(OR EQUAL) PIPE CLAMP <br />SECURE PIPE TO STUD WITHIN <br />2" OF BASE OF RISER WITH , <br />1/4" x 2" LONG LAG BOLT <br />WITH WASHERS, <br />6°° (MIN. <br />18" (MAX. <br />INTERIOR FINISHED FLOOR <br />2" <br />d a. <br />e d <br />d <br />Q <br />EXTERIOR WALL <br />GAS RISER IN WALL SEE <br />PIANS FOR SIZE. <br />4" MAX. <br />PROVIDE SIGN AT BUILDING <br />WHICH READS" <br />"BUILDING G - GAS SHUT <br />OFF VALVE". LOCATE SIGN <br />AT 48" AFG. <br />PRESSURE REDUCING VALVE <br />0 <br />GAS SMUT OFF VALVE <br />CATHODIC GAS RISER <br />.--� FINISHED GRADE <br />�li�lli�i111 <br />NOTES: <br />1. ALL EXPOSED GAS PIPING TO BE CLEANED, PRIMED, AND PAINTED (YELLOW). <br />CAST IRON OVERFLOW RAINWATER <br />EXTERIOR WALLLEADER, SEE PLANS FOR SIZE & <br />LOCATION. PROVIDE SUPPORT <br />BRACKET FOR EACH LENGTH, <br />4" MAX. WHERE NOZZLE IS INSTALLED AT STONE <br />DOWNSPOUT NOZZLE "ZURN" VENEER, EXTEND PIPING TO NOZZLE AS <br />Z-199. LOCATE BOTTOM OF REQUIRED. ALSO, SEAL NOZZLE AROUND <br />NOZZLE AT 12." AFG, STONE WITH ELASTOMERIC CAULK (CAULK TO <br />MATCH STONE COLOR) <br />ELBOW ADAPTER <br />FINISHED FLOOR <br />FINISHED GRADE <br />NXQ n <br />e <br />Q: Q <br />Q <br />OVERFLOW �INWATER LEADER DOWNSPOUT DEVIL <br />W <br />s � j <br />NTS <br />SECTION <br />INTERIOR CONCRETE SLAB <br />,�-�- EXTERIOR WALL <br />MIN. 1/2" PIPE WRAP, ALL AROUND <br />PIPING 0 CONC, CURB, TYP. <br />- PROVIDE MIN. 1" THICK CONC, <br />COVER OVER FOAM WRAP 0 <br />EXTERIOR SIDE OF CONC, CURB TYP. <br />CONCRETE MOW STRIP OR PAVING <br />AS OCCURS <br />I" FOAM PIPE WRAP, ALL AROUND <br />PIPING WHEN PENETRATING THRU <br />FOOTING <br />RWL PIPING <br />r--- CONCRETE FOOTING PER STRUCT, <br />I&T MJ 0 i ! An <br />AW <br />� <br />GAS COCK - LINE SIZE <br />(SEE PLANS FOR LINE SIZE.) <br />- UNION (TYP.) <br />�- - DIRT LEG <br />ZB-UNE (OR EQUAL) CE -SERIES PIPE <br />SUPPORT, SIMILAR TO DETAIL <br />NATURAL GAS PIPE, <br />SEE PLANS FOR SIZE <br />REDUCING UNION (AS REQUIRED) <br />REDUCE TO AC UNIT CONNECTION <br />SIZE <br />NOTES. <br />1. ALL EXPOSED GAS PIPING TO BE CLEANED, PRIMED, AND PAINTED (YELLOW). <br />2. FOR CLARITY, FLASHING NOT SHOWN. PROVIDE FLASHING FOR WATERTIGHT PENETRATIONS. <br />ROOFGAS CONNECTION <br />1/4" MIN. / 1 " MAX, <br />BUILDING OVERHANG <br />f <br />EXTERIOR WALL I <br />4" MAX. <br />GAS PIPE <br />PVC CAP <br />PVC TEE <br />11 i At <br />>#.:. <br />NO'S <br />AS REQUIRED <br />4"0 SCHEDULE 40 <br />PVC PIPE SLEEVE <br />A,.,! U,Aa ! BLOCKING WITH A35 <br />)TTOM WALL BLOCKING <br />1/2" HANGER ROD, SECURE TO <br />STRUCTURE PER DETAIL 1 /P5.1.1. <br />2" WIDE x10 GAUGE STEEL STRAP. <br />LOCATE LOWER STRAP TO BE AT 1/3 <br />HEIGHT OF HEATER, LOCATE TOP <br />STRAP AT 2/3 HEIGHT OF UNIT.. <br />2"x2px 1/4" ANGLE BRACE <br />NUT AND LOCKNUT EACH SIDE <br />GAUGE SHEET METAL PLATE <br />(APED TO CURVE OF WATER <br />ATER. <br />,TER HEATER STRAP <br />0 <br />AC UNIT <br />PROVIDE RUBBER GROMMET <br />AT ALL UNIT PENETRATIONS <br />�- SRING ISOLATION <br />/ ROOF CURB <br />ROOF SURFACE <br />EXTEND PIPE SLEEVE 14" <br />BEYOND BUILDING OVERHANG. <br />r VALVE BOX, PROVIDE WITH <br />EXTENSION AS REQUIRED <br />- GAS PIPE <br />END PIPE SLEEVE WITHIN VALVE <br />BOX, ANNULAR SPACE BETWEEN <br />PIPE AND SLEEVE TO BE OPEN. <br />A35 <br />WALL BLOCKING <br />WASHER EER -� 1/2"0 x 3-1/2- <br />LONG LAG SCREW <br />(TYP. OF 2) <br />2"x2"x1/4" WELDED FRAME SECURE TO WALL BACKING <br />PLATE WITH 1/2" x 3 1/2" LONG LAG SCREW/BOLT WITH <br />3" MINIMUM EMBEDMENT -� 2 PER FRAME (4 TOTAL) <br />--- SECURE STRAP TO WALL 1/2" x 3 1/2" (MIN) LONG <br />LAG SCREW/BOLT WITH 3'° MINIMUM EMBEDMENT. <br />PROVIDE WASHER AT EACH SCREW. SEE <br />-� °° ARCHITECTURAL DRAWINGS FOR BLOCKING DETAILS <br />12 <br />45' t <br />,r <br />5/16" STEEL PLATE WELDED TOj�� - <br />"L"s WITH 3/16" FILLET WELD ELECTRIC WATER HEATER, MOUNT <br />BOTTOM OF SUPPORT AT 7'-0" <br />� ��A*BOVE FINISHED FLOOR. <br />�tt`��` 8"" <br />THERMOMETER <br />PRESSURE AND TEMPERATURE RELIEF <br />VALVE, RUN DISCHARGE TO ADJACENT <br />FLOOR DRAIN, PROVIDE WITH A 1" <br />AIR GAP AT DISCHARGE <br />TIMECLOCK <br />UNION (TYP.) <br />'HERMO.I+�FTER <br />HOT WA R - ti <br />NTS <br />°-" HOT WATER RETURN <br />AQUASTAT <br />HOT WATER RECIRCULATING PUMP <br />BALL. VALVE TYP. <br />� �--- CHECK VALVE (TYP-) <br />�- COLD WATER <br />EXPANSION TANK, WATTS <br />MODEL DET -12 OR EQUAL <br />- DIELECTRIC UNION (TYP.) <br />ELECTRIC WATER HEATER, <br />MOUNT ON (E) FLOOR <br />WESTON <br />. ASSOCIATES <br />4701 ANNE WAY I CARMICHAEL, CA 95608 I 916) 482--0820 <br />WESTON & ASSOCIATES #15-012 <br />� pEE5S,1 <br />, <br />O A. W . 4e <br />0 No. M3122t3 ©' <br />3 n �' <br />L rn <br />RENEWAL ELATE: � <br />1�'� 1 213 1 1241 5 �' <br />CNAN�� CQ <br />Or Cfsk1 <br />Copyright 0 2014 Rainfed Grau Architects. All rights reserved. Reproduction of ftw plans, either In whoie or in part, indu(fiq any form <br />of copying ardor preparation rk de rNsWe works ihsreof, for any ream without prierwdbn pemission, is strlo€ly prIhlbited. <br />e <br />r 1 <br />r i <br />m , <br />r A IR I <br />DRAWN PROJECT NO. <br />DW 15-1207 <br />CHECKED DATE <br />DW 06-26-15 <br />SCALE SHEET <br />