NTS
<br />4 14" ACCESS PANEL
<br />Ic
<br />---- DRAIN LINE
<br />I �
<br />.,„.--------- -- FIXED AIR GAP, "SMITH" 3955
<br />14- 1" AIR GAP (MIN,)
<br />1 1/2" VR.
<br />CONNECT TO 2" WASTE
<br />DROP AS INDICATED ON
<br />PLUMBING FLOOR PIANS
<br />FLOOR 15" 2" WASTE DROP
<br />1
<br />El a'
<br />SINK AND/OR LAVATORY
<br />TAIL PIECE WITH INDIRECT DRAIN
<br />CONNECTION, "SIOUX CHIEF
<br />M
<br />FR." MODEL 200-066•
<br />/�p�/�)]+��1.[yyY lay'. { j 1Pa
<br />P -TRAP
<br />WALL. CLEANOUT
<br />r
<br />NTS
<br />2" DRAIN WITH CAST IRON P -TRAP
<br />3/4" CONDENSATE DROP
<br />DRAIN FROM FAN COIL UNIT -
<br />VENT
<br />3/4" COPPER PIPE, SPRAY PAINT TO
<br />MATCH CHROME PLATED CAST TUBE.
<br />EXTEND CONDENSATE DRAIN THRU
<br />WALL AND CONNECT TO TAIL
<br />PIECE INDIRECT BRANCH.
<br />ESCUTCHEON
<br />WASTE DROP
<br />REDUCED PRESSURE BACKFLOW PREVENTION
<br />UNIT (RPBP), "WATTS" MODEL 009A QT.
<br />CONNECT TO PIPING AS REQUIRED.
<br />STUD WALL I
<br />CW LINE
<br />1/2"
<br />1/2" BALL VALVE, p
<br />ACCESS PANEL LO
<br />TRAP PRIMER !
<br />PROVIDE MANIFOLD AND I
<br />MULTIPLE LINES & FUNNELS
<br />WHERE. TRAP PRIMER I
<br />SERVES MULTIPLE DRAINS I UNION
<br />t �
<br />1/2" CW DROP
<br />SEAL PENETRATION I
<br />WATER TIGHT
<br />FINISHED FLOOR
<br />FLOOR DRAIN OR SINK
<br />e
<br />C�" I
<br />• ,� , Q
<br />4
<br />4 - a
<br />1/2" CW TO TRAP,
<br />CONNECT AS REQUIRED.
<br />PROVIDE SLEEVE 1 "
<br />CLEAR AROUND PIPE
<br />OPEN TRENCH.
<br />I � IN11� i111� �111t�=-�
<br />PIPE,
<br />,9"MIN.
<br />FOR CASES OF LESS
<br />6„MIN. 1 THAN 3'--0” OTHER-
<br />WISE USE STEPPED
<br />CONCRETE & SLEEVE I I! FOOTING.
<br />FULL WIDTH, 9" OF NOT LESS NOT LESS SLOPE NOT MORE
<br />CONCRETE ADJACENT AN 18" THAN 18" THAN 1 IN 2. PIPE
<br />TO EITHER SIDE OF MUST NOT BE PLACED
<br />SLEEVE, BELOW THIS LINE
<br />RE' AT ON OF FIFES & TRENCHES TO FOUNDATIONS
<br />NTS
<br />SUPERSTRUT MODEL C -708-U
<br />(OR EQUAL) PIPE CLAMP
<br />SECURE PIPE TO STUD WITHIN
<br />2" OF BASE OF RISER WITH ,
<br />1/4" x 2" LONG LAG BOLT
<br />WITH WASHERS,
<br />6°° (MIN.
<br />18" (MAX.
<br />INTERIOR FINISHED FLOOR
<br />2"
<br />d a.
<br />e d
<br />d
<br />Q
<br />EXTERIOR WALL
<br />GAS RISER IN WALL SEE
<br />PIANS FOR SIZE.
<br />4" MAX.
<br />PROVIDE SIGN AT BUILDING
<br />WHICH READS"
<br />"BUILDING G - GAS SHUT
<br />OFF VALVE". LOCATE SIGN
<br />AT 48" AFG.
<br />PRESSURE REDUCING VALVE
<br />0
<br />GAS SMUT OFF VALVE
<br />CATHODIC GAS RISER
<br />.--� FINISHED GRADE
<br />�li�lli�i111
<br />NOTES:
<br />1. ALL EXPOSED GAS PIPING TO BE CLEANED, PRIMED, AND PAINTED (YELLOW).
<br />CAST IRON OVERFLOW RAINWATER
<br />EXTERIOR WALLLEADER, SEE PLANS FOR SIZE &
<br />LOCATION. PROVIDE SUPPORT
<br />BRACKET FOR EACH LENGTH,
<br />4" MAX. WHERE NOZZLE IS INSTALLED AT STONE
<br />DOWNSPOUT NOZZLE "ZURN" VENEER, EXTEND PIPING TO NOZZLE AS
<br />Z-199. LOCATE BOTTOM OF REQUIRED. ALSO, SEAL NOZZLE AROUND
<br />NOZZLE AT 12." AFG, STONE WITH ELASTOMERIC CAULK (CAULK TO
<br />MATCH STONE COLOR)
<br />ELBOW ADAPTER
<br />FINISHED FLOOR
<br />FINISHED GRADE
<br />NXQ n
<br />e
<br />Q: Q
<br />Q
<br />OVERFLOW �INWATER LEADER DOWNSPOUT DEVIL
<br />W
<br />s � j
<br />NTS
<br />SECTION
<br />INTERIOR CONCRETE SLAB
<br />,�-�- EXTERIOR WALL
<br />MIN. 1/2" PIPE WRAP, ALL AROUND
<br />PIPING 0 CONC, CURB, TYP.
<br />- PROVIDE MIN. 1" THICK CONC,
<br />COVER OVER FOAM WRAP 0
<br />EXTERIOR SIDE OF CONC, CURB TYP.
<br />CONCRETE MOW STRIP OR PAVING
<br />AS OCCURS
<br />I" FOAM PIPE WRAP, ALL AROUND
<br />PIPING WHEN PENETRATING THRU
<br />FOOTING
<br />RWL PIPING
<br />r--- CONCRETE FOOTING PER STRUCT,
<br />I&T MJ 0 i ! An
<br />AW
<br />�
<br />GAS COCK - LINE SIZE
<br />(SEE PLANS FOR LINE SIZE.)
<br />- UNION (TYP.)
<br />�- - DIRT LEG
<br />ZB-UNE (OR EQUAL) CE -SERIES PIPE
<br />SUPPORT, SIMILAR TO DETAIL
<br />NATURAL GAS PIPE,
<br />SEE PLANS FOR SIZE
<br />REDUCING UNION (AS REQUIRED)
<br />REDUCE TO AC UNIT CONNECTION
<br />SIZE
<br />NOTES.
<br />1. ALL EXPOSED GAS PIPING TO BE CLEANED, PRIMED, AND PAINTED (YELLOW).
<br />2. FOR CLARITY, FLASHING NOT SHOWN. PROVIDE FLASHING FOR WATERTIGHT PENETRATIONS.
<br />ROOFGAS CONNECTION
<br />1/4" MIN. / 1 " MAX,
<br />BUILDING OVERHANG
<br />f
<br />EXTERIOR WALL I
<br />4" MAX.
<br />GAS PIPE
<br />PVC CAP
<br />PVC TEE
<br />11 i At
<br />>#.:.
<br />NO'S
<br />AS REQUIRED
<br />4"0 SCHEDULE 40
<br />PVC PIPE SLEEVE
<br />A,.,! U,Aa ! BLOCKING WITH A35
<br />)TTOM WALL BLOCKING
<br />1/2" HANGER ROD, SECURE TO
<br />STRUCTURE PER DETAIL 1 /P5.1.1.
<br />2" WIDE x10 GAUGE STEEL STRAP.
<br />LOCATE LOWER STRAP TO BE AT 1/3
<br />HEIGHT OF HEATER, LOCATE TOP
<br />STRAP AT 2/3 HEIGHT OF UNIT..
<br />2"x2px 1/4" ANGLE BRACE
<br />NUT AND LOCKNUT EACH SIDE
<br />GAUGE SHEET METAL PLATE
<br />(APED TO CURVE OF WATER
<br />ATER.
<br />,TER HEATER STRAP
<br />0
<br />AC UNIT
<br />PROVIDE RUBBER GROMMET
<br />AT ALL UNIT PENETRATIONS
<br />�- SRING ISOLATION
<br />/ ROOF CURB
<br />ROOF SURFACE
<br />EXTEND PIPE SLEEVE 14"
<br />BEYOND BUILDING OVERHANG.
<br />r VALVE BOX, PROVIDE WITH
<br />EXTENSION AS REQUIRED
<br />- GAS PIPE
<br />END PIPE SLEEVE WITHIN VALVE
<br />BOX, ANNULAR SPACE BETWEEN
<br />PIPE AND SLEEVE TO BE OPEN.
<br />A35
<br />WALL BLOCKING
<br />WASHER EER -� 1/2"0 x 3-1/2-
<br />LONG LAG SCREW
<br />(TYP. OF 2)
<br />2"x2"x1/4" WELDED FRAME SECURE TO WALL BACKING
<br />PLATE WITH 1/2" x 3 1/2" LONG LAG SCREW/BOLT WITH
<br />3" MINIMUM EMBEDMENT -� 2 PER FRAME (4 TOTAL)
<br />--- SECURE STRAP TO WALL 1/2" x 3 1/2" (MIN) LONG
<br />LAG SCREW/BOLT WITH 3'° MINIMUM EMBEDMENT.
<br />PROVIDE WASHER AT EACH SCREW. SEE
<br />-� °° ARCHITECTURAL DRAWINGS FOR BLOCKING DETAILS
<br />12
<br />45' t
<br />,r
<br />5/16" STEEL PLATE WELDED TOj�� -
<br />"L"s WITH 3/16" FILLET WELD ELECTRIC WATER HEATER, MOUNT
<br />BOTTOM OF SUPPORT AT 7'-0"
<br />� ��A*BOVE FINISHED FLOOR.
<br />�tt`��` 8""
<br />THERMOMETER
<br />PRESSURE AND TEMPERATURE RELIEF
<br />VALVE, RUN DISCHARGE TO ADJACENT
<br />FLOOR DRAIN, PROVIDE WITH A 1"
<br />AIR GAP AT DISCHARGE
<br />TIMECLOCK
<br />UNION (TYP.)
<br />'HERMO.I+�FTER
<br />HOT WA R - ti
<br />NTS
<br />°-" HOT WATER RETURN
<br />AQUASTAT
<br />HOT WATER RECIRCULATING PUMP
<br />BALL. VALVE TYP.
<br />� �--- CHECK VALVE (TYP-)
<br />�- COLD WATER
<br />EXPANSION TANK, WATTS
<br />MODEL DET -12 OR EQUAL
<br />- DIELECTRIC UNION (TYP.)
<br />ELECTRIC WATER HEATER,
<br />MOUNT ON (E) FLOOR
<br />WESTON
<br />. ASSOCIATES
<br />4701 ANNE WAY I CARMICHAEL, CA 95608 I 916) 482--0820
<br />WESTON & ASSOCIATES #15-012
<br />� pEE5S,1
<br />,
<br />O A. W . 4e
<br />0 No. M3122t3 ©'
<br />3 n �'
<br />L rn
<br />RENEWAL ELATE: �
<br />1�'� 1 213 1 1241 5 �'
<br />CNAN�� CQ
<br />Or Cfsk1
<br />Copyright 0 2014 Rainfed Grau Architects. All rights reserved. Reproduction of ftw plans, either In whoie or in part, indu(fiq any form
<br />of copying ardor preparation rk de rNsWe works ihsreof, for any ream without prierwdbn pemission, is strlo€ly prIhlbited.
<br />e
<br />r 1
<br />r i
<br />m ,
<br />r A IR I
<br />DRAWN PROJECT NO.
<br />DW 15-1207
<br />CHECKED DATE
<br />DW 06-26-15
<br />SCALE SHEET
<br />
|