ALL ELECTRICAL COMPONENTS SHALL BE ANCHORED AND INSTALLED PER <br />THE DETAILS ON THE DSA APPROVED CONSTRUCTION DOCUMENTS. <br />WHERE NO DETAIL IS INDICATED, THE FOLLOWING COMPONENTS SHALL <br />BE ANCHORED OR BRACED TO MEET THE FORCE AND DISPLACEMENT <br />REQUIREMENTS PRESCRIBED IN THE 2013 CBC, SECTION 1616A.1.18 <br />THROUGH 1616A.1.26 AND ASCE 7-10 CHAPTERS 13,26 AND 30, <br />1. ALL PERMANTENT EQUIPMENT AND COMPONENTS. <br />2. TEMPORARY OR MOVABLE EQUIPMENT THAT IS PERMANENTLY <br />ATACHED (e.g. HARD WIRED) TO THE BUILDING UTILITY SERVICES <br />SUCH AS ELECTRICITY. <br />3. MOVABLE EQUIPMENT WHICH IS STATIONED IN ONE PLACE FOR <br />MORE THAN 8 HOURS AND HEAVIER THAN 400 POUNDS ARE <br />REQUIRED TO BE ANCHORED WITH TEMPORARY ATTACHEMENTS. <br />THE ATTACHEMENT OF THE FOLLOWING ELECTRICAL COMPONENTS <br />SHALL BE POSITIVELY ATTACHED TO THE STRUCTURE, BUT NEED NOT BE <br />DETAILED ON PLANS. THESE COMPONENTS SALL HAVE FLEXIBLE. <br />CONNECTIONS PROVIDED BETWEEN THE COMPONENT AND ASSOCIATED <br />CONDUIT. <br />A. COMPONENTS WEIGHTING LESS THAN 400 POUNDS AND HAVE A <br />CENTER OF MASS LOCATED 4 FEET OR LESS ABOVE THE <br />ADJACENT FLOOR OR ROOF LEVEL THAT DRIRECTLY SUPPORT THE <br />COMPONENT. <br />B. COMPONENTS WEIGHING LESS THAN 20 POUNDS, OR IN THE CASE <br />OF DISTRIBUTED SYSTEMS, LESS THAN 5 POUNDS PER FOOT, <br />WHICH ARE SUSPENDED FROM A ROOF OR FLOOR. OR HUNG FROM <br />A WALL. <br />FOR THOSE ELEMENTS THAT DO NOT REQUIRE DETAILS ON THE <br />APPROVED DRAWINGS, THE INSTALLATION SHALL BE SUBJECT TO THE <br />APPROVAL OF THE STRUCTURAL ENGINEER OF RECORD AND THE DSA <br />DISTRICT STRUCTRAL ENGINEER. THE PROJECT INSPTECOR WILL VERIFY <br />THAT ALL COMPONENTS AND EQUIPMENT HAVE BEEN. ANCHORED IN <br />ACCORDANCE WITH THE ABOVE REQUIREMENTS. <br />ELECTRICAL DISTRIBUTION SYSTEMS SHALL BE BRACED TO COMPLY WITH <br />THE FORCES AND DISPLACEMENTS PRESCRIBED IN ASCE 7-10 SECTION <br />13.3 AS DEFINED IN ASCE 7-10 SECTION 13.3 AS DESCRIBED IN ASCE 7-10 <br />SECTION 13.5.3, 13.6.7, 13.6.5.6 AND 2013 CBC, SECTIONS 1616A.1.23, <br />1616k 124,1616A. 125 AND 1616A. 1.26. <br />THE BRACING AND ATTACHEMENS TO THE STRUCTURE SHALL BE <br />DETAILED TO THE APPROVED DRAWINGS OR THEY SHALL COMPLY WITH <br />ONE OF THE OSHPD PRE -APPROVALS (OPM #) AS MODIFIED TO SATISFY <br />.ANCHORAGE REQUIREMENTS OF ACI 313, APPENDIX D. <br />COPIES OF THE MANUAL SHALL BE AVAILABLE ON THE JOBSITE PRIOR TO <br />THE START OF HANGING AND BRACING OF ELECTRICAL DISTRIBUTION <br />SYSTEMS. <br />THE STRICTURAL ENGINEER OF RECORD SHALL VERIFY THE; ADEQUACY <br />OF THE STRUCTURE TO SUPPORT THE HANGER AND BRACE LOADS. <br />& <br />AND <br />DESCRIPTION <br />WK- <br />E0.1 <br />AT <br />KVA <br />ONE THOUSAND VOLT -AMPS <br />CL <br />CENTERLINE <br />KW <br />ONE THOUSAND WATTS <br />° <br />DEGREE <br />TITLE 24 COMPLIANCE <br />NONE. <br />(E) <br />EXISTING <br />NONE <br />yM- <br />(ER) <br />EXISTING RELOCATED <br />MAX.. <br />MAXIMUM <br />'G` <br />GREEN INSULATED GROUND <br />MCB <br />MAIN CIRCUIT BREAKER <br />(N) <br />NEW <br />MECH. <br />MECHANICAL <br />1P, 2P, 3P <br />ONE POLE, TWO POLE, ETC. <br />MFR. <br />MANUFACTURER <br />% <br />PERCENT <br />MIN. <br />MINIMUM <br />0 <br />PHASE <br />MLO <br />MAIN LUGS ONLY <br />+ <br />PLUS/MINUS <br />MT <br />EMPTY CONDUIT W/ PULL -LINE <br /># <br />POUND OR NUMBER <br />ONE LINE DIAGRAM, FEEDER SCHEDULE, PANELS <br />NONE <br />(R) <br />RELOCATE <br />NONE <br />-N- <br />W/ <br />WITH <br />N.I.E.S, <br />NOT INCLUDED IN ELECTRICAL <br />W/O <br />WITHOUT <br />DETAILS <br />SCOPE <br />E5.3 <br />DETAILS <br />N.T.S. <br />NOT TO SCALE <br />DETAILS <br />.A- <br />NL <br />NIGHT LIGHT <br />AC <br />ALTERNATING CURRENT <br />NEC <br />NATIONAL ELECTRIC CGDE <br />AL, ALUM. <br />ALUMINUM <br />NEMA <br />NATIONAL ELECTRICAL <br />A, AMPS <br />AMPERES <br />E5.9 <br />MANUFACTURED ASSOCIATION <br />AWG <br />AMERICAN WIRE GAUGE <br />DETAILS <br />NONE <br />AIC <br />AMPERES INTERRUPTING <br />NONE <br />_O. <br />RELAY WITH ENCLOSURE. <br />CAPACITY <br />O.C. <br />ON CENTER <br />A.F.F. <br />ABOVE FINISHED FLOOR <br />O.F.C.I. <br />OWNER FURNISHED <br />ATS <br />AUTO TRANSFER SWITCH <br />LINE VOLTAGE AUTOMATIC "ON/OFF" CEILING MOUNTED DUAL TECHNOLOGY <br />OCCUPANCY SENSOR. SENSORSWITCH #CMRWPDT--9 <br />CONTRACTOR <br />LABEL TO MARK PLUG LOAD RECEPTACLE TO BE DETERMINED. <br />INSTALLED <br />-13o <br />O.F.O.I. <br />OWNER. FURNISHED OWNER <br />BRKR. <br />BREAKER <br />INSTALLED <br />BTR <br />BUILDING TELECOM ROOM <br />EXISTING CONDUIT RUN TO BE ABANDONED. CONDUIT ABOVE THE FLOOR <br />_x_ - _x_ <br />AND BELOW THE STRUCTURE ABOVE SHALL BE REMOVED. CONDUCTORS <br />P- <br />-------- <br />-C- <br />PVC <br />POLYVINYL CHLORIDE CONDUIT <br />C <br />CONDUIT <br />BRANCH CIRCUIT WITHOUT FURTHER DESIGNATION INDICATES A 2 #12 AWG <br />CB <br />CIRCUIT BREAKER <br />-R- <br />C.E.C. <br />CALIFORNIA ELECTRICAL CGDE <br />REF <br />ROOF EXHAUST FAN <br />CLG. <br />CEILING <br />REQ'D. <br />REQUIRED <br />CU <br />COPPER <br />RLA <br />RUNNING LOAD AMP <br />ADJACENT TO STRAIGHT OR CURVED CROSS -LINES INDICATES WIRE SIZE. <br />RSC <br />RIGID STEEL CONDUIT <br />"D- <br />CONDUIT RACEWAY SLEEVE.. <br />DC <br />DIRECT CURRENT <br />��- <br />S - <br />DIA. <br />DIAMETER <br />SIM. <br />SIMILAR <br />DWG <br />DRAWING <br />SPEC. <br />SPECIFICATION <br />DIST. <br />DISTRIBUTION <br />SWBD. <br />SWITCHBOARD <br />SWGR <br />SWITCHGEAR <br />.Ea <br />EA. <br />EACH <br />_T - <br />f EMT <br />ELECTRIC METALLIC TUBING <br />TER <br />TELECOM EQUIPMENT ROOM <br />TP <br />TAMPER PROOF <br />.F- <br />TR <br />TELECOM ROOM <br />F.A. <br />FIRE: ALARM <br />T.V. <br />TELEVISION <br />FLA <br />FULL LOAD AMPERES <br />TYP. <br />TYPICAL <br />FT <br />FOOT OR FEET <br />FACP <br />FIRE ALARM CONTROL PANEL <br />U- <br />FATC <br />FIRE ALARM TERMINAL CABINET <br />U.L. <br />UNDERWRITERS LAB. <br />U.O.N. <br />UNLESS OTHERWISE NOTED <br />"G- <br />UPS <br />UNINTERRUPTIBLE POWER <br />l GA <br />GAUGE <br />SUPPLY <br />GEN <br />GENERATOR. <br />_V_ <br />GFCI <br />GROUND FAULT CIRCUIT <br />V <br />VOLTS <br />INTERRUPTING <br />VAC <br />VOLTS ALTERNATE CURRENT <br />_H- <br />_W,° <br />H.I.A, <br />HIGH INTENSITY DISCHARGE <br />W <br />WATTS <br />HP <br />HORSE POWER <br />WP <br />WEATHERPROOF <br />WG <br />WIRE GUARD <br />IG <br />ol,o <br />ISOLATED GROUND <br />X- <br />XFMR <br />TRANSFORMER <br />_j_ <br />J -BOX <br />JUNCTION BOX <br />SHEET INDEX <br />SHEET <br />DESCRIPTION <br />SCALE <br />E0.1 <br />ABBREVIATIONS, SHEET INDEX & SYMBOLS <br />DONE <br />E0.2 <br />SCHEDULES <br />NONE <br />E0.3 <br />TITLE 24 COMPLIANCE <br />NONE <br />E0.4 <br />TITLE 24 COMPLIANCE <br />NONE. <br />E0.5 <br />TITLE 24 COMPLIANCE <br />NONE <br />E1.1 <br />ELECTRICAL SITE PLAN <br />1'" = 30' <br />E1.2 <br />ELECTRICAL SITE PLAN - DEMOLITION <br />1" = 30' <br />E2.1.1 <br />LIGHTING PLAN <br />4,f 19.056 <br />E2.1.2 <br />POWER PLAN" <br />= 1"-01' <br />E2.1.3 <br />POWER PLAN - ROOF" <br />r <br />E2.1.4 <br />KITCHEN POWER PLAN, EQUIPMENT SCHEDULE <br />4" = 11-011 <br />E2.1.5 <br />SIGNAL PLAN <br />4" 19_0„ <br />E2.1.6 <br />FIRE ALARM PLAN <br />8 1'-d" <br />E3.1 <br />FIRE ALARM NOTES, MATRIX, DETAIL, RISER <br />NONE <br />E3.2 <br />FIRE ALARM CALCULATIONS <br />NONE <br />E4.1 <br />ONE LINE DIAGRAM, FEEDER SCHEDULE, PANELS <br />NONE <br />E4.2 <br />LOW VOLTAGE SYSTEMS WIRING DIAGRAM, FIRE ALARM SYSTEM <br />NONE <br />" <br />77 <br />WIRING DIAGRAM <br />119� p"7v9.1 <br />E5.1 <br />DETAILS <br />NONE <br />E5.2 <br />DETAILS <br />NONE <br />E5.3 <br />DETAILS <br />NONE <br />E5.4 <br />DETAILS <br />NONE <br />E5.5 <br />DETAILS <br />NONE <br />E5.6 <br />DETAILS <br />NONE <br />E5.7 <br />DETAILS <br />NONE <br />E5.8 <br />DETAILS <br />NONE <br />E5.9 <br />DETAILS <br />NONE <br />E5,10 <br />DETAILS <br />NONE <br />E5.11 <br />DETAILS <br />NONE <br />"ANDARD ELECTRICAL SYMBOLS <br />SYMBOL <br />DESCRIPTION <br />SURFACE MOUNTED LUMINAIRE. <br />FLEX CONDUIT WITH WIRING FROM JUNCTION BOX TO DEVICE. WIRE SIZE, <br />QUANTITY AND GROUND CONDUCTOR AS REQUIRED. <br />........................ <br />CONDUIT WITH LOW VOLTAGE LIGHTING CONTROL WIRING. <br />_LTl <br />CONDUIT WITH LIGHTING CONTROL WIRING. <br />SURFACE MOUNTED LUMINAIRE. <br />FIRE ALARM SYSTEM CONDUIT AND WIRING. <br />FIRE <br />SPADE CONDUIT WITH PULL LINE. <br />SP --- <br />--COMM--- <br />MECHANICAL CONTROL SYSTEM CONDUIT AND WIRING. <br />POLE MOUNTED LUMINAIRE. <br />INTRUSION ALARM CONDUIT AND WIRING. <br />IA <br />DATA <br />DATA COMMUNICATIONS CONDUIT AND WIRING. <br />S <br />- <br />DATA COMMUNICATIONS CONDUIT AND WIRING. <br />DATA COMMUNICATIONS CONDUIT AND WIRING. <br />S <br />X 0-I <br />FUSED DISCONNECT SWITCH WITH CLASS 'R' DUAL ELEMENT FUSES, SIZE <br />TO SUIT EQUIPMENT NAME: PLATE RATING. NUMBER ADJACENT INDICATES <br />AMPERE RATING OF SWITCH. <br />X&J <br />THERMAL MAGNETIC CIRCUIT BREAKER DISCONNECT, NUMBER ADJACENT <br />INDICATES AMPERE RATING OF SWITCH. <br />me = MOMENTARY CONTACT. <br />CONTROL AND/OR EQUIPMENT, N.I.E.S., INSTALL AND CONNECT AS READ, <br />20 AMP 125V 3W DUPLEX CONVENIENCE. RECEPTACLE, MOUNTED +16" A.F.F. <br />MOTOR, N.I.E.S., CONNECT AS REQUIRED. <br />r <br />FIRE SPRINKLER RISER BELL, BELL N.I.E.S., CONNECT AS REQ'D. <br />(+15" A.F.F. MINIMUM) TO BOTTOM OF BOX. <br />DISTRIBUTION PANEL/MOTOR CONTROL CENTER. <br />® <br />BRANCH CIRCUIT PANELBOARD, SURFACE MOUNTED. <br />+16" A.F.F. (+15" A.F.F. MINIMUM) TO BOTTOM OF BOX. <br />BRANCH CIRCUIT PANELBOARD, FLUSH MOUNTED. <br />® <br />TERMINAL CABINET HINGED NEMA 1 SURFACE MOUNTED SIZE AS REQUIRED. <br />TELEPHONE TERMINAL BACKBOARD, 4'x8'x3/4" PLYWOOD WITH 1/2"C - 'I #6G' <br />TO GROUND BAR.. <br />m <br />GROUND - TYPICAL AT TRANSFORMER, TERMINAL CABINETS, TERMINAL <br />BOARDS AND PANELBOARDS. <br />SOLID FILLED RECEPTACLE DESIGNATES TAMPER RESISTANT <br />GROUND BUS BAR. <br />RECEPTACLE, TYPE AS INDICATED ON PLANS. <br />NUMBERED NOTE. <br />' <br />EQUIPMENT TAG, PROVIDE EQUIPMENT AND/OR CONNECTIONS AS REQ'D. <br />- <br />PLAN OR DETAIL CALL OUT. <br />" <br />77 <br />EQUIPMENT DESIGNATION, <br />119� p"7v9.1 <br />PANEL AND BRANCH CIRCUIT DESIGNATION, CONNECT TO PANEL AND <br />CIRCUIT INDICATED. <br />1arol�A <br />AIC SHORT CIRCUIT RATING. <br />S2 <br />TWO POLE HORSEPOWER RATED DISCONNECT SWITCH. <br />F-9 <br />BACKSTOP WINCH CONTROLLER PROVIDED BY EQUIPMENT MANUFACTURER, <br />CONTRACTOR INSTALLED. COORDINATE WITH EQUIPMENT CONTROLLER <br />SPECIFIED IN 11480. <br />r -WA -P-1 <br />WIRELESS ACCESS POINT, SURFACE MOUNTED. <br />C = ABOVE COUNTER MOUNTED, SEE ARCHITECTURAL DRAWINGS. <br />LIGHTING CONTROL PANEL. <br />0 CH <br />JUNCTION BOX, SIZE AND TYPE AS INDICATED OR REQUIRED. <br />El <br />EMERGENCY POWER POWER. nLIGHT #nPP16 ER WITH OPTIONAL TEST <br />SWITCH. MOUNT ABOVE GRID CEILING WHERE APPLICABLE. PROVIDE ACCESS <br />DOOR AT HARD LID CEILING LOCATIONS. <br />T = THERMAL OVERLOAD, FLUSH MOUNTED IN FINISHED AREAS. <br />SOUND SYSTEM SPEAKER ARRAY. <br />TELEPHONE/DATA OUTLET, 4 11/16" SQUARE. X 2 1/8" DEEP BOX W/ I -DEVICE <br />SOUND SYSTEM SUB WOOFER SPEAKER. <br />I� <br />SOUND SYSTEM BLEACHER SPEAKER. <br />PP <br />LIGHTING CONTROL POWER. PACK ATTACHED TO J -BOX ABOVE CEILING, SEE <br />WIRING DIAGRAM ON DETAIL SHEET, nLIGHT #nPP16 <br />FL <br />PLUG LOAD POWER PACK ATTACHED TO J -BOX ABOVE CEILING, SEE WIRING <br />DIAGRAM ON DETAIL SHEET. FLIGHT #nPP16 PL T24 <br />AUTOMATIC "ON/OFF" DUAL TECHNOLOGY OCCUPANCY SENSOR W/ DIMMING <br />CONTROL, WALL MOUNTED +48" A.F.F. TO TOP OF BOX. STUB VC INTO <br />ACCESSIBLE CEILING SPACE, TERMINATE W/ INSULATED BUSHING. <br />nLIGHT #nWSX PDT LV DX WH <br />D -I <br />1 -POLE DIMMING CONTROLS, WALL MOUNTED x-45" A.F.F. TO TCP OF BOX. <br />STUB 1"C INTO ACCESSIBLE CEILING SPACE, TERMINATE W/ INSULATED <br />BUSHING. nLIGHT ##nPODM DX <br />1 = (1) ACTIVATED DATA DROP <br />LIME VOLTAGE DUAL TECHNOLOGY OCCUPANCY SENSOR., WALL MOUNTED <br />+48" A.F.F. TO TOP OF BOX. SENSORSWITCH #W8X PDT <br />dS <br />AUTOMATIC "ON/OFF" CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY <br />SENSOR. nLIGHT #nCM PDT 9 <br />P1 <br />CEILING MOUNTED PHOTOSENSOR FOR DAYLIGHT CONTROL, AUTOMATIC <br />SWITCHING AND DIMMING FOR ONE LIGHTING ZONE. <br />nLIGHT #nCM ADCX <br />M <br />RELAY WITH ENCLOSURE. <br />USED ONLY AT CMU WALL LOCATIONS, <br />IP CLOCK WITH WIRE GUARD. <br />P� <br />SECURITY SYSTEM, MOTION SENSOR, SONITROL. <br />KP <br />SECURITY SYSTEM, KEYPAD, SONITROL. <br />ENCLOSURE TO BE USED ONLY AT CMU WALL LOCATIONS. <br />SECURITY SYSTEM, MAGNETIC DOOR CONTACT. <br />OL <br />LINE VOLTAGE AUTOMATIC "ON/OFF" CEILING MOUNTED DUAL TECHNOLOGY <br />OCCUPANCY SENSOR. SENSORSWITCH #CMRWPDT--9 <br />STANDARD ELECTRICAL SYMBOLS <br />SYMBOL DESCRIPTION <br />SURFACE MOUNTED LUMINAIRE. <br />a a <br />SUSPENDED LUMINAIRE. <br />RECESSED MOUNTED LUMINAIRE. <br />0 <br />SURFACE MOUNTED LUMINAIRE. <br />(�H <br />WALL MOUNTED LUMINAIRE. <br />RECESSED MOUNTED LUMINAIRE. <br />WALL MOUNTED ILLUMINATED EXIT SIGN. <br />0-0 <br />POLE MOUNTED LUMINAIRE. <br />LUMINAIRE SHADING INDICATES LUMINAIRE CONNECTED TO EMERGENCY <br />POWER SOURCE. MINIMUM 90 MINUTE EMERGENCY OPERATION. <br />B <br />LUMINAIRE TAG, LETTER INDICATES TYPE, SEE LUMINAIRE SCHEDULE. <br />S <br />SINGLE POLE TOGGLE SWITCH, MOUNTED +48" A.F.F. MAX TO TOP OF BOX. <br />s aS Ia <br />SWITCH SUBSCRIPTS; a,b,c = DEVICE CONTROL, p = PILOT LIGHT, k = KEYED, <br />S kS ma <br />me = MOMENTARY CONTACT. <br />20 AMP 125V 3W DUPLEX CONVENIENCE. RECEPTACLE, MOUNTED +16" A.F.F. <br />(+15" A.F.F. MINIMUM) TO BOTTOM OF BOX. <br />20 AMP 125V 3W DOUBLE DUPLEX CONVENIENCE RECEPTACLE, MOUNTED <br />+16" A.F.F. (+15" A.F.F. MINIMUM) TO BOTTOM OF BOX. <br />20 AMP 125V 3W DUPLEX CONVENIENCE RECEPTACLE W/ GROUND FAULT <br />INTERRUPTER, MOUNTED +16" A.F,F. (+15" A.F.F. MIN.) TO BOTTOM OF BOX, <br />SOLID FILLED RECEPTACLE DESIGNATES TAMPER RESISTANT <br />RECEPTACLE, TYPE AS INDICATED ON PLANS. <br />NEMA 14-50R RECEPTACLE, MOUNTED +16" A.F.F. (+15" A.F.F. MINIMUM) <br />TO BOTTOM OF BOX. <br />DOUBLE FACED PEDESTAL DUPLEX RECEPTACLE, REFER TO FOODSERVICE <br />EQUIPMENT ELECTRICAL FLOOR PLAN, CONNECTED BY ELECTRICAL <br />CONTRACTOR. <br />NEMA 5-15R RECEPTACLE, MOUNTED +16" A.F.F. (+15" A.F.F. MINIMUM) <br />TO BOTTOM OF BOX. <br />SUBSCRIPTS <br />DEVICE SUBSCRIPTS DESIGNATE THE FOLLOWING: <br />C __Q <br />C = ABOVE COUNTER MOUNTED, SEE ARCHITECTURAL DRAWINGS. <br />TK <br />TK T OUTLET MOUNTED TOE KICK. <br />L <br />L = KEYED S.S. LOCKING COVER. <br />T S <br />T = THERMAL OVERLOAD, FLUSH MOUNTED IN FINISHED AREAS. <br />TELEPHONE/DATA OUTLET, 4 11/16" SQUARE. X 2 1/8" DEEP BOX W/ I -DEVICE <br />RING AND PLATE, MOUNTED +16" A.F.F (-x-15" A.F.F. MINIMUM) TO BOTTOM OF <br />BOX. STUB 1.25" CONDUIT INTO ACCESSIBLE CEILING SPACE, TERMINATE W/ <br />INSULATING BUSHING. ACTIVATED DEVICES. (1) DATA & (1) TELEPHONE. <br />TD = (1) ACTIVATED TELEPHONE / (1) ACTIVATED DATA DROPS <br />'777 <br />,77 <br />1 = (1) ACTIVATED DATA DROP <br />2 -- (2) ACTIVATED DATA DROPS <br />IP COMBINATION CLOCK/SPEAKER ENCLOSURE AND BAFFLE FOR RECESSED <br />FLUSH MOUNTED APPLICATIONS. SURFACE MOUNT ENCLOSURE TO BE <br />USED ONLY AT CMU WALL LOCATIONS, <br />IP OUTDOOR WEATHERPROOF SPEAKER, ENCLOSURE AND BAFFLE. <br />FOR RECESSED FLUSH MOUNTED APPLICATIONS. SURFACE MOUNT <br />ENCLOSURE TO BE USED ONLY AT CMU WALL LOCATIONS. <br />20 AMP 125V 3W PLUG LOAD CONTROLLED SPLIT CIRCUIT DUPLEX <br />RECEPTACLE, MOUNTED +16" A.F.F. (+15" A.F.F. MIN.) TO BOTTOM OF BOX. <br />LABEL TO MARK PLUG LOAD RECEPTACLE TO BE DETERMINED. <br />20 AMP 125V 3W PLUG LOAD CONTROLLED SPLIT CIRCUIT DOUBLE DUPLEX <br />RECEPTACLE, MOUNTED +16" A.F.F. (+15" A.F.F. MIN.) TO BOTTOM OF BOX. <br />LABEL TO MARK PLUM LOAD RECEPTACLE TO BE DETERMINED, <br />RACEWAY INSTALLED IN CEILING OR WALL. ROUTE EXPOSED IN ALL <br />UNFINISHED AREAS. <br />-®--- <br />RACEWAY INSTALLED BELOW FINISHED FLOOR OR GRADE. <br />EXISTING CONDUIT RUN TO BE ABANDONED. CONDUIT ABOVE THE FLOOR <br />_x_ - _x_ <br />AND BELOW THE STRUCTURE ABOVE SHALL BE REMOVED. CONDUCTORS <br />SHALL BE REMOVED. <br />-------- <br />EXISTING CONDUIT RUN, VERIFY ROUTING ON THE JOB. <br />ARROW AT END OF RACEWAY INDICATES HOME RUN TO RESPECTIVE <br />PANELBOARD OR SWITCHBOARD, <br />BRANCH CIRCUIT WITHOUT FURTHER DESIGNATION INDICATES A 2 #12 AWG <br />CIRCUIT WITH 1 #12 AWG GROUND. <br />STRAIGHT CROSS -LINES IN BRANCH CIRCUIT RACEWAY INDICATE NUMBER <br />OF #12 AWG WIRES IN A CIRCUIT. SHORT LINES INDICATE UNGROUNDED <br />CONDUCTORS. LONG LINES INDICATE NEUTRAL CONDUCTORS. WIRES <br />SHOWN ARE IN ADDITION TO 1 #12 AWG GROUNDING CONDUCTOR. <br />BRANCH CIRCUIT WITH GROUNDING WIRE LARGER. THAN #12 AWG. NUMBER <br />#1G <br />ADJACENT TO CURVED CROSS -LINE INDICATES WIRE SIZE. <br />BRANCH CIRCUIT RACEWAY WITH WIRE OTHER. THAN #12 AWG. NUMBER <br />ADJACENT TO STRAIGHT OR CURVED CROSS -LINES INDICATES WIRE SIZE. <br />#io <br />UNGROUNDED AND NEUTRAL CONDUCTORS SHALL BE THE SAME SIZE <br />UNLESS OTHERWISE NOTED. <br />CONDUIT RACEWAY SLEEVE.. <br />INDICATES RACEWAY TURNING UP. <br />��- <br />INDICATES RACEWAY TURNING DOWN. <br />INDICATES RACEWAY STUB, TERMINATE W/ BUSHING OR CAP IF <br />UNDERGROUND. <br />APPLICABLE CODES <br />ALL WORK PERFORMED UNDER THIS CONTRACT IS TO CONFIRM TO THE FOLLOWING <br />ODES AND REGULATIONS: <br />1. CALIFORNIA ADMINISTRATIVE CODs:., 2013 3 <br />2: CALIFORNIA BUILDING CODE, 2013 <br />3.' CALIFORNIA .MECHANICAL CODE, 2013. <br />4. CALIFORNIA PLUMBING CODE, 2013 <br />5,i CALIFORNIA FIRE CODE, 2013 <br />6.1, CALIFORNIA ELECTRICAL CODE, 2013 <br />`i.;=. CALIFORNIA ENERGY CODE, 2013 <br />THIt ABOVE CODES AND REGULATIONS REFER TO THE LATEST EDITION OR REVISION IF I <br />FORCE ON THE DALE OF THE CONTRACT, UNLESS OTHERWISE STATED. NOTHING ON <br />THE DRAWINGS IS TO BE CONSTRUED AS REQUIRING OR PERMITTING WORK THAT ,IS <br />CONTRARY TO THE LISTED CODES AND REGULATIONS, OR OTHER LOCAL, STATE OR <br />FEDERAL._ CODES OR REGULATIONS WHICH MAY BE APPLICABLE. <br />No. E 017376{n : <br />Exp. 9-30-16 <br />Copyright C 2009 Rainforth Crau Architects. All rights reserved. Reproduction of these dans, either in whole or in part, including any form j <br />of copying and/or preparation of derivative woft thereof, for any reason without prior written permission, is strictly prohibited. 1 <br />LSSA <br />File No. .. <br />F'IDENTIFICATION STAMP <br />L}IV. OF THE STATE ARCHITECT <br />ggqE) <br />AC - FLS RV l aS <br />DATE <br />zzzzsu si <br />DRAVVN IDLY PROJECT NO. 15-1207 <br />CHECKED DATE <br />YSL 6-26-15 <br />SCALE SHEET <br />AS SHOWN <br />4/9 4/269 5 4 6}:24;26 M <br />