Laserfiche WebLink
NOTES: <br />1. COORDINATE EXACT LOCATION WITH <br />ELECTRICAL SUBCONTRACTOR. <br />2. INSTALL CONTROLLER TO MALL WITH <br />MOUNTING KIT. <br />3, AUTOMATIC CONTROLLER TO BE INSTALLED <br />PLUMB AND LEVEL. <br />AUTOMATIC CONTROLLER WITH <br />WALL MOUNT KIT <br />110 V ELECTRIC SERVICE <br />SEE ELECTRICAL DRAWINGS <br />2" PVC CONDUIT FOR CONTROL WIRE <br />2" PVC LONG SWEEP ELL AND CONDUIT <br />TO PLANTER. SEE ELECTRICAL DRAWINGS <br />CONCRETE SLAB - - <br />SEE ARCHITECTURAL DRAWINGS <br />AUTOMATIC CONTROLLER DETAIL <br />NOTES: <br />1. REFER TO LEEMCO MANUEL FOR JOINT <br />RESTRAINT REQUIREMENTS FOR ALL.. FITTINGS. <br />L = LENGTH IN WHICH JOINT RESTRAINT 45 REQUIRED <br />2. ALL LEEMCO HARDWARE TO BE STAINLESS STEEL. <br />y� <br />0 <br />0 <br />L <br />NOTES: <br />1. FOR GROUNDING THE CONTROLLER, THE CONTRACTOR MAY USE EITHER METHOD SHOWN, GROUNDING ROD OR GROUNDING PLATE. <br />2, GROUNDING RODS SHALL BE DRIVEN INTO THE EARTH WITH TOPS NOT LESS THAN 12" BELOW THE FINISH GRADE. <br />3, THE GROUNDING GRID SHALL BE TESTED FOR EARTH RESISTANCE, USING A VIBRA GROUND, MEGAR OR OTHER APPROVED TYPE <br />INSTRUMENT. THE TEST SHALL NOT BE RUN UNTIL THE GROUNDING GRID HAS BEEN INSTALLED FOR A FEW WEEKS AND THE EARTH <br />HAS HAD AN OPPORTUNITY TO "SETTLE" AROUND THE RODS. THE RESISTANCE OF THE GROUNDING ROD SMALL NOT BE GREATER <br />THAN 15 OHMS. TO HAVE A GROUNDING NETWORK, THAT WILL BE AS EFFECTIVE AS POSSIBLE, THE RESISTANCE SHALL BE 5 OHMS <br />OR LESS, IF NECESSARY THE GROUNDING GRID MAY NEED TO BE TREATED WITH SALT OR OTHER TYPE CHEMICAL IN ORDER TO <br />IMPROVE IT. REMEMBER THAT THE EFFECTIVENESS OF THE SURGE ARRESTOR IS DRASTICALLY REDUCED AS THE RESISTANCE GOES <br />"UP". ANYTHING OVER 15 OHMS RENDERS THE SURGE ARRESTOR ALMOST OF NO VALVE IN PROTECTING THE EQUIPMENT. <br />4. IF DESIRED RESISTANCE IS NOT ACHIEVED, CONTRACTOR TO INSTALL ANOTHER GROUNDING ROD OR PLATE SO THE ELECTRODE SPHERE <br />OF INFLUENCE BOUNDARIES DO NOT OVERLAP, <br />UL COPPER GROUND PL <br />(4" X 96" X .0625") <br />#6 AWG SOLID BARE CC <br />WIRE <br />! AUTOMATIC CONTROLLER <br />90 DEGREE LEEMCO SELF -RESTRAINED FITTING <br />PVC PIPE <br />LEEMCO PIPE -TO -PIPE RESTRAINT, LPP SERIES <br />1 _ SET VALVE BOX LEVEL, PLACE LOCATOR INSIDE. <br />VALVE BOX TO BE LEVEL WITH GRADE. <br />2, INSTALL VALVE BOX EXTENSIONS AS REQUIRED. <br />3. CONNECT ALL WIRES WITH WEATHER TIGHT CONNECTORS. <br />SPLICES IN WIRE SHALL BE PERMITTED ONLY AT VALVE LOCATIONS. <br />4. TAPE AND BUNDLE WIRE EVERY 10 FEET <br />5. PROVIDE 18" EXPANSION LOOP AT EACH WIRE CONNECTION <br />IN VALVE BOX <br />6. ALL LEEMCO HARDWARE TO BE STAINLESS STEEL. <br />FINISH GRADE <br />w <br />tx <br />o w <br />Al <br />-LATERAL FOR <br />POP-UP AND <br />BUBBLER HEADS <br />LATERAL FOR <br />I ROTOR HEADS <br />6, FOR VALVES WITH PRESSURE REGULATION <br />FEATURE, <br />SET VALVE PRESSURE AS PER <br />MANUFACTURERS RECOMMENDATIONS TO THE <br />PRESSURE <br />AS FOLLOWS: <br />POP --UP SPRAY HEADS: <br />35 <br />- 40 <br />PSI <br />INTERMEDIATE POP --UP ROTOR HEADS: <br />50 <br />- 55 <br />PSI <br />POP-UP ROTOR HEADS: <br />60 <br />- 70 <br />PSI <br />BUBBLER HEADS:: <br />30 <br />- 4.0 <br />PSI <br />DRIP SYSTEMS: <br />15 <br />- 20 <br />PSI <br />VALVE BOX, SETTINGS, AND CLEARANCES <br />4" 2' <br />4' 9' <br />6 AWG SOLID BARE CC <br />WIRE <br />_.. -_--__._._-.---- <br />I <br />2 <br />NOTES: <br />1. REFER TO LEEMCO MiANUEL FOR JOINT <br />RESTRAINT REQUIREMENTS FOR ALL FITTINGS. <br />L = LENGTH IN WHICH JOINT RESTRAINT IS REQUIRED <br />2. ALL LEEMCO HARDWARE TO BE STAINLESS STEEL. <br />:.LECTRODE <br />SPHERE OF <br />NFLUENCE <br />3OUNDARIES <br />PVC SWEEP ELL <br />(1 1/2" OR LAr <br />6 AWG SOLID I <br />COPPER `MIRES <br />JL COPPER CLAD GROUND ROD <br />;5/8" X 10`) <br />* OR BELOW FROSTLINE, WHICHEVER IS DEEPER <br />SECTION <br />LEEMCO PIPE -TO -PIPE RESTRAINT, LPP SERIES <br />LEEMCO LH SERIES JOINT RESTRAINT <br />LEEMCO TEE FITTING <br />PVC PIPE <br />ROTATED VIEW OF TEE <br />COMPONENTS INSTALLATION <br />212 VALVE <br />JE BOX, MO.1220-12 <br />TOWN COVER, AND <br />TENSION. GREEN COLOR <br />AUTOMATIC CONTROLLER <br />CONCRETE PAD <br />CARSON VALVE BOX, MODEL 910 <br />WITH BOLT DOWN COVER, GREEN <br />COLOR, OR APPROVED EQUAL. <br />CADWELD CONNECTION <br />NOTES: <br />1. OF 14 WIRE AND COMMUNICATION CABLE NOT SHOWN, SEE OVERALL SCHEMATIC LAYOUT DETAIL. <br />2. VALVE BOX AND LID TO BE CONCRETE H2O TRAFFIC RATED. TOP OF BOX TO BE LEVEL, FLUSH TO FINISH <br />GRADE IF LOCATED IN PAVED AREA,, 1" ABOVE FINISH GRADE IF LOCATED IN NON PAVED AREA. USE <br />VALVE BOX EXTENSIONS AS REQUIRED TO ENCASE VALVE AND PIPE WITHIN BOX WITH A 3" CLEARANCE BELOW. <br />ALL PENETRATION SHALL BE SEALED FROM THE INSIDE. <br />NORMALLY OPEN <br />'MASTER SOLENOID <br />CONTROL VALVE <br />VALUE BOX <br />FROM BACKFLOW <br />EARTH CONTACT MATERIAL PREVENTION DEVICE <br />3 <br />i <br />UL COPPER GROUND PLATE <br />UL COPPER CLAD GROUND ROD <br />"110 - O "` ;► <br />D EQUAL. CARSON VALVE BOX, MODEL 910 WITH BOLT - -� <br />ON DEC=ODER DOWN COVER, GREEN COLOR, OR APPROVED EQUAL <br />8' X 5/8" UL COPPER CLAD GROUND ROD -- <br />10' ,6 SOLID COPPER GROUND WIRE �--- �- <br />I <br />3 <br />ONTROL VALVE CARSON VALVE BOX, MODEL 910 WITH BOLT <br />E j DOWN COVER, GREEN COLOR, OR APPROVED EQUAL <br />3N (2 REQ'D.) i CAD WELD CONNECTOR <br />E <br />THREAD INTO 801H <br />TOMATIC CONTROL VALVE 8 X 5/8" UL COPPER CLAD GROUND ROD <br />10' #6 SOLID COPPER GROUND WIRE <br />np-rnnp-p <br />OTHER AUTO. <br />_VE ON SAME <br />Q'D. PLACE <br />:R BASE OF BOX. <br />IVER ROCK, 6" DEEP <br />SERIES ADAPTER <br />PVC PIPE <br />kBLE <br />--RAL TEE <br />TWO WIRE <br />CABLE <br />TO P VI EW <br />3 <br />FLOW SENSOR <br />10 PIPE DIAMETERS <br />STRAIGHT PIPE <br />NO FITTINGS <br />MV <br />5 PIPE <br />DIAMETERS <br />STRAIGHT PIPE <br />NO FITTINGS <br />TO SPRINKLER <br />SYSTEM <br />' 4- � <br />FS <br />VALVE BOX <br />DISTANCE CHART <br />REFER TO THE FOLLOWING TABLE THAT LISTS THE LENGTH (IN FEET) FOR EACH SIZE/TYPE FITTING WITHIN WHICH ALL <br />JOINTS JUST BE RESTRAINED. ALL FITTINGS AND JOINT RESTRAINTS SHALL BE INSTALLED PER MANUFACTURERS <br />RECOMMENDATIONS & SPECIFICATIONS. <br />AS AN EXAMPLE, IF YOU ARE INSTALLING A 3" MAINLINE W4TH A DIRECTIONAL CHANCE OF 90`, REFER TO CHART <br />UNDER PIPE SIZE TO 3" AND UNDER BENDS 90 YOU WILL SEE THE DISTANCE OF 11'. IF THERE IS ANY JOINT <br />(VALVE, BELL, ETC.) YOU MUST INSTALL A JOINT RESTRAINT WITHIN 11' OF THE 90' MAINLINE DIRECTIONAL CHANGE. <br />i <br />PIPE BENDS <br />REDUCERS <br />DEAD END <br />i SIZE 1 1' <br />22° 45° <br />900 <br />1 STEP 12 STEP <br />5 STEP, <br />BLIND SERV. B. <br />2" 1' <br />1' 2' <br />6' <br />_ <br />- <br />19' 6' <br />2.5 1 ' <br />2' 4' <br />9' <br />1 4 - <br />4 <br />23'10' <br />3" <br />4 <br />5Z8" x 5.5" 100 <br />8' 10 <br />4 <br />.30 15 <br />4" 2' <br />4' 9' <br />20' <br />14' 20 <br />31 <br />45' 25' <br />6" <br />1 <br />30' 4Li <br />53' <br />4 " <br />8"4' <br />15 <br />_ <br />�33' S5' <br />- <br />63' <br />7. ' 70' <br />10 55''' <br />12 5 -- .._.._...1..0'._.. <br />9' 19 <br />21' - <br />45' <br />- 53' -- <br />36 56' <br />- - --38 -- -- - - ----6 5 -- - <br />75'� <br />- --- 83' --- -- - <br />_ _ <br />96' 90' <br />- 112' ---.....__.-._1.1_ t�'..-.__...._ <br />INSTALLATION CHART <br />REFER TO THE FOLLOWING TABLE WHICH LISTS THE NUMBER OF BOLTS, SIZE, AND TORQUE FOR EACH BOLT IN <br />REFERENCE TO THE SIZE OF P[PE WHICH IS BEING RESTRAINED. <br />AS AN EXAMPLE, IF YOU HAVE A 3" PIPE, YOU WILL NEED 2 BOLTS THAT ARE 3/8 X 2.5" AND TIGHTEN THEM <br />WITH A TORQUE WRENCH TO 20 FT -LBS. <br />PIPE <br />SIZE <br />NO_ <br />BOLTS <br />BOLT I TORQUE <br />SIZE 1I='T­LBS. <br />2" <br />2 <br />3/8" x 2.5" 20 <br />2.5" <br />2 <br />3 8" x 2.5" 20 <br />3" <br />2 <br />3 8" x 2.5" 20 <br />4" <br />2 <br />1 2" x 3°' 50 <br />6" <br />2 <br />j 2 °' x 3.5" 50 <br />8" <br />4 <br />1 2" x 4" 50 <br />10 <br />4 <br />5Z8" x 5.5" 100 <br />12" <br />4 <br />5/8" x 5.5" 100 <br />CONTACT NUNZIO DICHRISTOPHER 0 (916) 202-1333, THE LEEMCO REPRESENTATIVE, FOR ALL QUESTIONS <br />CONCERNING LEEMCO PRODUCTS. COORDINATE AN INSTALLATION CLINIC WITH NUNZIO PRIOR TO INSTALLING THE <br />MAINLINE. <br />LEEI1lIO® MINT RESTRAINTS CHART <br />NOTE: <br />1. MOUNT ON ANY SURFACE WHERE IT WILL BE <br />EXPOSED TO UNOBSTRUCTED RAINFALL, BUT WIRELESS RECEIVER <br />NOT IN PATH OF SPRINKLER SPRAY, <br />2. MOUNT NO MORE THAN 1000' FROM THE <br />RECEIVER UNIT WITH A CLEAR LINE OF SITE. <br />3, MOUNT RECEIVER UNIT NO MORE THAN 6' <br />FROM THE CONTROLLER. F9C) <br />15-24 <br />MTwg 0 u <br />Mama y a c <br />Take hara <br />W o r o n i e c k i <br />LANDSCAPE ARCHITECTURE <br />AND PLANNING <br />10411 Cold Placerville Road <br />.S'6I%1`G 20.5" <br />916369-3990 <br />Peter D, Larimer C-5284 <br />Copyright 0 2014 Rainforth Srau Architects. All rights reserved. Reproduction of these plans, eliher in whole or in pari, including any form <br />of copying and/or preparation of derivative works thereof, for any reason without prior written permission, is strictly prohibited. <br />DSA <br />File No. 39-53 <br />IDENTIFICATION STAMP <br />DIV. OF THE STATE ARCHITECT <br />02-114490 INC 1 <br />AC,L FLS,,,- SS <br />WIRELESS RAIN SENSOR <br />WITH MOUNTING ARM DATE IC <br />MOUNT WIRELESS RAIN <br />SENSOR A MINIMUM OF <br />G0" ABVERADE °OR FINISH LINCOLN E.S. CAFETERIA <br />PEDESTRIAN CLEARANCE <br />REQUIREMENTS <br />CLASSROOM MODERNIZATION, <br />EXTERIOR WALL (SEE NOTE) INCREMENT 1: CAFETERIA <br />MANTECA UNIFIED SCHOOL DISTRICT <br />ANTECA. CALIFORNIA <br />SECTION VIEW <br />__.__._..___.. __._._...___._._------._._._-__ __-__.__---______.________.------_,_--_.---------------.__. <br />9 DECODER GROUNDING ROD �C? WIRELESS RAIN SENSOR DETAIL <br />r- --- <br />- -J <br />DRAWN PROJECT N©. <br />PL 15-12117 <br />GHECKI=L3 DATE <br />PL 6 26-15 <br />SCALE SHEET <br />