Laserfiche WebLink
ACOUSTICAL CEILINGS <br />Section 09510 <br />15-1207 <br />1) SDS greater than 1.15 and less than 1.73: <br />For z/h greater than 0.5: 8'x 12' <br />For z/h less than or equal to 0.5: 12'x 12' <br />2) SDS greater than 1.73: <br />For z/h greater than 0.5: 8'x 8' <br />For z/h less than or equal to 0.5: 8'x 12' <br />2. Method of Attachment: Secure all lateral bracing to structural members as shown on <br />the plans. Secure at right angles to the direction of the partition and four ways in large <br />ceiling areas. <br />3. Attachment of bracing wires shall be in accordance with ASTM C636, Part 2, and as <br />shown; no splicing is allowed. <br />C. Compression Struts: Install per drawings at bracing wire lateral force bracing. Compression <br />strut shall resist vertical component of force induced by the bracing wires. Fasten strut to <br />main runner and extend to and fasten to the structural members supporting the floor or roof <br />above. <br />1. Strut and diagonal bracing shall be designed and constructed in compliance with the <br />DSA IR, and shall not be more than 1 (horizontal) in 6 (vertical) out of plumb. <br />2. Provide solid blocking wherever necessary for proper installation and connection at <br />strut to floor or roof framing. <br />D. Acoustical Ceiling Panels: <br />1. Install acoustical panels in coordination with suspended system, with edges resting on <br />flanges of main runner and cross tees. Cut and fit panels neatly against abutting <br />surfaces. Support edges by wall moldings. <br />2. Cut and rabbet edges of tegular edge acoustical panels, at border areas and vertical <br />surfaces to exactly match factory cut tegular edge. <br />3. Panel weighing more than'/2 P.S.F. shall be positively attached to ceiling runners in <br />accordance with IR 25-2-13. <br />E. Demolition of Existing Suspended Ceiling System and Panels: <br />Where existing suspended acoustical ceilings are indicated to be removed, unless <br />otherwise noted, this includes the acoustical panels, ceiling grid, all accessories and <br />trim, hanger wires, bracing wire, compression struts, and any other components that <br />are a part of the existing ceiling system. All components for the specified ceiling <br />system are to be new. <br />3.04 ADJUSTING AND CLEANING <br />A. Upon completion, clean soiled and discolored surfaces so that installation is free from <br />defects. Remove and replace damaged or improperly applied material, as directed. <br />B. Acoustical ceiling panels, acoustical ceiling tile and suspended ceiling system shall be free of <br />scratches, stains, smudges, fingerprints, discolorations, breaks, chips or other damage. <br />Finished ceilings shall be uniform in appearance, including uniform color and texture. <br />E <br />