My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
1400
>
2300 - Underground Storage Tank Program
>
PR0231951
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2021 12:05:00 PM
Creation date
10/18/2021 8:14:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231951
PE
2361
FACILITY_ID
FA0003704
FACILITY_NAME
DART CONTAINER CORP
STREET_NUMBER
1400
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04932015
CURRENT_STATUS
01
SITE_LOCATION
1400 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Recommended Practices for the Testing and Verification of Spill,Overfill,Leak Detection and Secondary Containment Equipment at UST Facilities <br /> 7.3.3 Description of Test. The procedures in 8. Reconnect the probe cable and turn on power <br /> this test are for overfill alarms that are an integral to monitor. <br /> part of a typical ATG that uses magnetostrictive 9. Set the fuel float in the middle of the probe and <br /> probes for fuel level measurements in the UST.The <br /> verify that it is showing the correct inch read- <br /> ATG probe is removed from the tank. When the ing on the monitoring panel. <br /> product float is moved to the position correspond- <br /> ing to the 90 percent fill level, the alarm should 10.Slowly move the fuel float up the probe until <br /> activate. the overfill alarm is triggered. If the float <br /> is moved too quickly, it may not trigger the <br /> 7.3.4 Preparation. Use this test procedure in alarm. <br /> conjunction with the monitoring system manufac- <br /> turer's installation and maintenance instructions. 11-Measure the distance from the bottom of the <br /> probe to the bottom of the fuel float (confirm <br /> Refer to the tank manufacturer's tank chart for the different manufacturers point of measurement <br /> capacity in gallons,the diameter and the volume of on the float) when the float first triggers the <br /> product that corresponds to the product level. alarm. <br /> When possible,print out the system setup to verify 1.2.On the tank chart, find the volume that corre- <br /> the proper configuration of the ATG. sponds to the height of the float and determine _ <br /> the percent of tank capacity. <br /> 7.3.5 Test Equipment. Test equipment shall Use this formula to determine the percent of <br /> include: <br /> tank capacity at which the alarm was triggered: <br /> • tools for the removal of the ATG probe; <br /> Percent Tank Capacity = (product volume <br /> • tape measure or gauge stick. when 90 percent alarm triggered/total tank 3 <br /> 7.3.6 Test Procedure. volume) x 100 <br /> 13.Clear the alarm condition. <br /> 1.Measure the product level in the tank riser <br /> where the ATG probe has been removed and 14.Compare the measurements in Steps I 1 and 12 <br /> compare to the console reading to confirm ATG to the values programmed into the console. <br /> accuracy. If the reading does not agree, contact 15.Reinstall the ATG probe. <br /> the appropriate person. <br /> 2.Verify that the overfill alarm on the ATG is set to 7.3.7 Pass/Fail Criteria. <br /> provide a warning when the tank is no more than If the overfill alarm(s)activates when the tank is <br /> 90 percent full. Consult the tank chart for the no more than 90 percent full, the overfill alarm <br /> inch-level setting for 90 percent tank volume. passes the test. <br /> 3.Verify on the ATG console that the overfill alarm • If the fuel level on the console does not agree <br /> circuit is operational. with the gauge stick reading,the system fails the <br /> 4.Activate the overfill alarm warning to verify test. <br /> its operation. If found defective, contact the • If the overfill alarm(s) does not activate in the <br /> appropriate person. test mode, it fails the test. <br /> 5.Remove the ATG probe cap and disconnect the • If the overfill alarm(s) does not activate or <br /> cable from the ATG. activates at any product level above 90 percent <br /> 6. Remove the ATG probe from the tank. Use tank capacity, it fails the test. <br /> care to ensure that the product float on the stem <br /> does not catch on the bottom of the riser during <br /> removal. <br /> 7.Inspect the probe. The floats must move freely <br /> on the stem without binding. <br /> pei.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.