My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
1400
>
2300 - Underground Storage Tank Program
>
PR0231951
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2021 12:05:00 PM
Creation date
10/18/2021 8:14:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231951
PE
2361
FACILITY_ID
FA0003704
FACILITY_NAME
DART CONTAINER CORP
STREET_NUMBER
1400
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04932015
CURRENT_STATUS
01
SITE_LOCATION
1400 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C <br /> Recommended Practices for the Testing and Verification of Spill,Overfill,Leak Detection and Secondary Containment Equipment at UST Facilities = <br /> Verify that the console has no active or ;k.;'� • L - <br /> recurring history of leak detection-related <br /> warnings or alarms. In the event of any r J. {r1• ?, _ _ <br /> such warnings or alarms, notify the appro- <br /> priate person before continuing the test. <br /> Where possible print out the system setup ��!' ',F` �Y "';: * z � - <br /> and any alarm histories from the console. - <br /> Save the printout for facility records or <br /> make an electronic copy. <br /> 8.2.1.5 Test Equipment. Test equip- <br /> ment shall include: - K <br /> • tools for the removal of the ATG probe <br /> and sensors; <br /> • tape measure or gauge stick; <br /> • water-finding paste. <br /> 8.2.1.6 Test Procedure. <br /> 1. Measure the product and water level € <br /> in the tank and compare to the console <br /> readings to confirm ATG accuracy. If <br /> the readings do not agree, contact the FIGURE 8-2. When removing and replacing the ATG <br /> appropriate person. probe, be careful to avoid damaging any of the compo- <br /> 2. Remove the ATG probe cap and nents. <br /> disconnect the cable from the ATG. <br /> 9. Clear the alarm conditions. <br /> 3. Remove the ATG probe from the tank. <br /> Use care to ensure that the floats on 10. For the water float, slowly move the <br /> float the probe until the water <br /> alarm s <br /> the stem do not catch on the bottom s triggered. <br /> i <br /> of the riser during removal. <br /> 4. Inspect the probe. The floats must u• Measure the distance from the bottom <br /> move freely on the stem without of the probe to the water float when <br /> binding. If any parts are damaged the float first triggers the water alarm. <br /> or missing, contact the appropriate 12. Compare the measurements for prod- <br /> person. uct float and the water float in Steps 8 <br /> 5. Reconnect the probe cable. and I I to the values programmed into <br /> the console. <br /> 6. Set the fuel float in the middle of the <br /> probe and verify that it is showing the 8.2.1.7 Pass/Fail Criteria. If the mea- <br /> correct inch reading on the console. surements for the product and water floats <br /> match the values programmed in the con- <br /> 7. Slowly move the fuel float up the sole and the console acknowledges the <br /> probe until the high product alarm is high product and water level alarms, the <br /> triggered on the console.If the system ATG probe passes the test. <br /> does not alarm at the pre-set level, <br /> contact the appropriate person. If the measurements for the product and <br /> 8. Measure the distance from the bottom water floats do not match the values pro- <br /> of the probe to the fuel float when the grammed in the console or the console <br /> float first triggers the high product does not acknowledge the high product <br /> alarm. or water level alarms, the ATG probe fails <br /> the test. <br /> pei.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.