My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
866
>
1600 - Food Program
>
PR0507015
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/16/2022 4:39:25 PM
Creation date
10/20/2021 9:41:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0507015
PE
1623
FACILITY_ID
FA0007685
FACILITY_NAME
RAMEN 101
STREET_NUMBER
866
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09741020
CURRENT_STATUS
01
SITE_LOCATION
866 W BENJAMIN HOLT DR
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
on"')REVISIONS r�RE\ ISIONS <br /> DESCRIPTION DATE: <br /> HOOD INFORMATION Job 2053190 w �Nrw� T�1�nu - Al <br /> By <br /> EXHAUST PLENUM HOOD CONFIG. HlIG7H TEMP L1r„IP40LU CES CLEAR L <br /> HOOD <br /> MAX. EXHAUST <br /> HOOD NOTE:MODEL ND-2 IS AN ETL LISTED HOOD aaa®�R IS1rAQ1%ITGL�(4M RK1111111W) <br /> 0 <br /> TAG MODEL LENGTH COOKING TOTAL END TO <br /> NO. CONSTRUCTION ROW ETL LISTING IS 200 CFM/FT(600 DEGREES) D <br /> TEMP. EXH.CFM WIDTH LENG. DIA. CFM S.P. END Q=ETL LISTING* 160"=3200 CFM<4400 CFM(DESIGN) <br /> IF1EM WMAPPER 11SLIM"fHlKdf+l zi� <br /> 5424 16'0.00" 600 Deg. 4400 10" 42" 4400 -1.028" 430 SS ALONE ALONE MODEL ND-2 IS ETL LISTED WITH 1 EX RISER UP TO 16' (PEE O"ONS raa�) <br /> 1 �HI9CUll�lrl�l <br /> ND-2 Where Exposed <br /> HOOD INFORMATION ON FILTER(S) LIGHT(S) UTILITY CABINET(S) �N <br /> HOOD FIRE SYSTEM ELECTRICAL SWITCHES FIRE HOOD E <br /> TAG WIRE SYSTEM HANGING p 01NO. TYPE QTY. HEIGHT LENGTH QTY. TYPE LOCATION 7--T <br /> v <br /> GUARD TYPE SIZE MODEL# QUANTITY PIPING WIGHT <br /> FILTER Wn 1HI HOOK I <br /> 1 Captrate Solo Filter 12 20" 16" 5 L55 Series E26 NO Right Ansul R102 3.0/3.0 SC-ElOO11102 1 Light YES 668 LBS <br /> 1 Fan <br /> "IIMIiII) 1LTfARlqIDDIFIF I I Q o <br /> HOOD OPTIONS <br /> HNO D TAG OPTION I I I I <br /> 1 FIELD WRAPPER 16.00" High Front,Left, Right <br /> ccn <br /> v <br /> BACKSPLASH 80.00" High X 204.00" Long 430 SS ITISTHEIRESPONSBUTT <br /> OFTHEARICHIIfTf1ECTOWMERTO I I I I I I <br /> Ef SUIRIE T HA-T THE HOW CLEMMCIE <br /> 61ILJIMMEHI)-�TNIELIE <br /> 3" /RlKIRIGMMUSMELIEWIATERIALS <br /> ISIRGOVIPLANICIEVAIMH I I I J <br /> ILOC44L Cam IREMMMEMEMM. <br /> 9.. I W <br /> O <br /> 10" 0) <br /> Z w W 41�A1"10019 I N <br /> } WO'Ar HH REWMABLECUIP CA <br /> 42" Z U)U <br /> OZ< 00 <br /> H (n W �SHI5M.W11IINIQa"rHl <br /> a co <br /> 54" Z W Of �C�11..(�"w LL <br /> U.L.Listed L55 Series E26 Canopy Light Fixture- 111 <br /> 0-w VERIFY CEILING HEIGHT 1 <br /> High Temp Assembly D-D_ N <br /> (no aLo z 0 <br /> LUZ <br /> r N O <br /> Q Height required to verify that the hood W LID -5 00 U <br /> will fit and to size the enclosure panels V v � N O <br /> W LL I- 2 <br /> Z <br /> utility FIAT O � <br /> Cabinet 0- � � V <br /> a I CD W W 1 <br /> X <br /> LIGHT FAN <br /> ND-2 Series S ecification ` v C LL <br /> FAN SWITCHES p rn <br /> CASHMI INTERFACE Q The model ND-2 is an exhaust only canopy hood rated for all types of cookingU I;n W M w <br /> equipment.The hood shall have the size,shape and performance specified on LU W 0 <br /> drawings. m 0 � N <br /> 0) C <br /> Construction shall be type 430 stainless steel,with a#3 or#4 polish where - W <br /> exposed.The manufacturer,ETL m < J <br /> 12" <br /> and NSF shall determine the individual component construction.Construction Q <br /> 16'0.00"Nom./16'0.00"OD shall be dependent on the o W <br /> structural application to minimize distortion and other defects.All seams,joints U o <br /> 17'-0.00"Overall Length SECTION VIEW — MODEL ,�424ND-2 <br /> and penetrations of the hood enclosure to the lower outermost perimeter that m N <br /> directs and captures grease-laden vapor and exhaust gases shall have a HOOD — n Q co <br /> liquid-tight continuous external weld in accordance with NFPA 96.The hood shall oo <br /> PLAN VIEW Hood—L1 be wall type with a minimum of four connections for hanger rods.Connectors <br /> shall have 9/16"holes pre-punched in 1 %"x 1 Y2"angle iron at the factory to <br /> 16' 0.00" LONG 5 42 4 N D—2 allow for hanger rod connection by others. <br /> NOTE: Additional hanging angles provided for hoods 12'and longer. <br /> The hood shall be furnished with U.L.classified filters,supplied in size and 0 <br /> quantity as required by ventilator. <br /> LO <br /> The filters shall extend the full length of the hood and the filler panels shall not be 0) <br /> more than 6"in width. Q <br /> DEMONSTRATIONS ARE AVAILABLE AT THE 0 <br /> The hood manufacturer shall supply complete computer generated submittal Z Z <br /> drawings including hood sections CALIFORNIA BAY AREA DISPLAY CENTER <br /> view(s)and hood plan view(s).These drawings must be available to theFOR PRICES AND QUESTIONS, CALL 0 <br /> engineer,architect and owner for their use in construction,operation and DANNY NG <br /> maintenance. REFERENCE JOB#2053190 = UO <br /> Exhaust duct collar to be 4"high with 1"flange.Duct sizes,CFM and static REG91 @CAPTIVEAIRE.COM F__ <br /> pressure requirements shall be as shown on drawings.Static pressure PHONE:(415)956-2200 FAX:(919)227-5940 Cn <br /> requirements shall be precise and accurate;air velocity and volume <br /> information shall be accurate within 1-ft increments along the length of the W 0 <br /> ventilator. <br /> J <br /> U.L.incandescent light fixtures and globes shall be installed and pre-wired to a 0 <br /> junction box.The light fixtures shall be installed with a maximum of 4'0"spacing z O <br /> on center and allow up to a 100 watt standard light bulb. Z <br /> LU <br /> The hood shall have: <br /> -A double wall insulated front to eliminate condensation and increase rigidity. ~ Z <br /> 2"FLANGE TO The insulation shall have a flexural modulus of 475 El,meet UL 181 PLENUM PROTECTION <br /> NOZZLEW Z <br /> FASTEN TO WALL requirements and be in accordance with NFPA 90A and 90B. < U G C LU <br /> m <br /> -An integral front baffle to direct grease laden vapors toward the exhaust filter <br /> FLANGED FORWRAPPER PANELS LU <br /> bank. DUCTNOZZLE PROTECTION ' ) <br /> WALL / RIGIDITY -A built-in wiring chase provided for outlets and electrical controls on the hood DETECTORS W < 0 <br /> �. face and shall not co <br /> WRAPPER END penetrate the capture area or require an external chase way. a CD <br /> -Removable grease cup for easy cleaning. z <br /> O O <br /> The hood shall be ETL Listed as"Exhaust Hood Without Exhaust Damper", NSF <br /> FACTORY WELDED Listed and built in accordance with NFPA 96. Z Y <br /> WRAPPER MOUNTING <br /> FRONT CHANNEL APPLIANCE PROTECTION <br /> NOZZLE REMOTE MANUAL <br /> Stainless Steel Backs ash INSTALLER TO The hood shall be listed for 450°F cooking surfaces at 150 CFM/ft,600°F PULL STATION C U HOOD SHEET <br /> FASTEN WRAPPER SPECIAL I/8"KINK cooking surfaces at 200 CFM/ft,and 700°F cooking surfaces at 250 CFM/ft.The c O <br /> and S i d e s p I a s h SEE DETAIL WRAPPER FRONT TO FACTORY hood shall be ETL Listed as"Exhaust Hood Without Exhaust Damper". <br /> CHANNEL <br /> Backsplash is t0 be manufactured from #3 O 4 REMOVABLE STAINLESS vJ <br /> STAINLESS OPTIONAL PRE-WIRED ELECTRICAL <br /> finish SSS Of the same guage and ma erial s the TERMINAL BOX WITH TERMINAL STRIPS, STEEL SERVICE DOOR <br /> POP-RIVETS AGENT TANK <br /> hoods. It Will be supplied With Batton strips an BY OTHERS 3-PHASE CONTACTABLE) OVERLOADS <br /> P P P (IF APPLICABLE) FAN AND LIGHT QROFESSION <br /> end strips as needed to close all seams and edges. CONTROL PANEL OEM RELEASE/ DATE• q( <br /> 1/2" WRAPPER END BRACKET ASSEMBLY \�\t���Q� XI A p HF C <br /> FIELD DRILLED HOLES <br /> TYPICAL ANSUL R-102 SYSTEM LAYOUT <br /> ln�= DETAIL <br /> No. <br /> . 6-30-21 <br /> 1-3/8" DRAWN <br /> Batton Strip Metall FIELD WRAPPER BY: �TgTFOF CA F���\P <br /> SCALE: <br /> 3/4" = V-0" <br /> CORNER HANGING ANGLE DETAIL ND-2 CAPTRATE & KLEEN-CARD FILTERS ® ® <br /> FOR QUESTIONS, CALL THE CAPTIVE—AIRE HOODS ARE CAPTRATE CAPTRATE ® ° KLEEN-GARD <br /> 1/2" DIA. ALL THREAD ROD STEEL HANGING ANGLE ARE BUILT IN COMPLIANCE WITH n ® ® MASTER DRAWING <br /> CONNECTED TO ROOF JOIST` CAPTIVE-AIRE SYSTEMS BUILT IN COMPLIANCE WITH GREASE-STO19 SOLO GREASE-STO19 COMBO ° SS BAFFLE TYPE <br /> THROUGH ANOTHER CENTRAL CALIFORNIA OFFICE DmT I I ° ° <br /> HANGING ANGLE BUILT =NSFA FILTER INFORMATION FILTER INFORMATION ° FILTER INFORMATION Designed by : T.W <br /> ® ACCORDANCE <br /> Region 91 <br /> �OSTEO �Aigp U <iSTEO <br /> InterQalk Date : Oct 5, 2020 <br /> 1/2" DIA. HEAVY DUTY NUT 8 ADRIAN COURT NEPA #96 NOM. SIZE ACTUAL DIMENSIONS FREE AREA WEIGHT VELOCITY STATIC PRESSURE NOM. SIZE ACTUAL DIMENSIONS FREE AREA WEIGHT VELOCITY STATIC PRESSURE NOM. SIZE ACTUAL DIMENSIONS FREE AREA WEIGHT VELOCITY STATIC PRESSURE <br /> AND WASHER — ONE ABOVE BURLINGAME, CA 94010 NFPA #96 NSF STANDARD #2 (H x W) (H x W x D) (SQ. FEET) (LBS) (FPM) (WATER GAUGE) (H x W) (H x W x D) (SQ. FEET) (LBS) (FPM) (WATER GAUGE) (H x W) (H x W x D) (SQ. FEET) (LBS) (FPM) (WATER GAUGE) <br /> AND ONE BELOW HANGING ANGLE UL 710 & ULC710 STANDARDS UL STANDARD #1046 SHEET NO. <br /> PHONE: (415) 956-2200 E.T.L. LISTED 3054804-001 INT. MECH. CODE IMC 20 x 20 19-5/8" x 19-5/8" x 1-70��8 11 100 0.25 20 x 20 19-5/8" x 19-5/8" x 1-7�� g 15 100 0.50 20 x 20 19-5/8" x 19-5/8" x 1-7 � 3 11 100 0.25 <br /> EMAIL: REG91@CAPTIVEAIRE.COM ( ) Scale : AS SHOWN <br /> 20 x 16 19-5 8" x 15-5 8" x 1-7 S78 8.9 125 0.35 20 x 16 19-5 8" x 15-5 8" x 1-7 878 12 125 0.70 20 x 16 19-5/8" x 15-5/8" x 1-7�8�3 8.9 125 0.35 1 <br /> ROD, NUTS, AND WASHERS TO BE SUPPLIED BY INSTALLING CONTRACTOR 16 x 20 15-5/8" x 19-5/8" x 1-7A8J8 9.1 150 0.45 16 x 20 15-5 8" x 19-5 8" x 1-7 �l8 12 150 0,90 16 x 20 15-5/8" x 19-5/8" x 1-7X83 9.1 150 0.45 <br /> HANGING ANGLE IS PRE-PUNCHED AT FACTORY X - X - 15-5 8 X 15-5 8 X 1-7 8 15-5 8 x 15-5 8 x 1-7 <br /> 16 x 16 — 39 7.4 175 0.75 16 x 16 .39 10 175 1.20 16 x 16 835 7.4 175 0.75 <br /> Drawn : W.P.D. <br /> Job : <br /> SHEET <br /> H = 1 <br /> OF SHEETS <br />
The URL can be used to link to this page
Your browser does not support the video tag.