My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
STONEWOOD
>
1405
>
3600 - Recreational Health Program
>
PR0541197
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2024 4:29:24 PM
Creation date
10/20/2021 12:38:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
WORK PLANS
RECORD_ID
PR0541197
PE
3612
FACILITY_ID
FA0000922
FACILITY_NAME
VISTA VERDE APARTMENTS
STREET_NUMBER
1405
STREET_NAME
STONEWOOD
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
21621019
CURRENT_STATUS
01
SITE_LOCATION
1405 STONEWOOD AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MAIN PLAN DESCRIPTION OF PROJECT REVISIONS BY <br /> SCALE 1" = 20' EXISTING POOL EQUIPMENT ENCLOSURE <br /> Remodel of Existing Swimming Pool <br /> PROPERTY LINE Construction of New Spa <br /> --------------------------------- ------------------------ <br /> ----------------- -------------------------------------------------------------------------------------------------------- <br /> EXISTING POOL/SPA SAFETY SIGNAGE I <br /> NEW SPA BEING INSTALLED--\ Z_LOCATED ON FENCE I <br /> I <br /> FENCE LINE I POOL SCOPE OF WORK <br /> Li Drain Pool <br /> \ EXISTING COVERED I Strip Plaster to Substrate <br /> PATIO m., <br /> Install Trim Tile on Shallow End Steps <br /> 2x2 Black, Flush with Plaster, Slip-Resistant <br /> 20 ft.4 in. [a---- a--- EI <br /> Install Breakline Tile at 4 Y2' Depth <br /> Existing Recessed Pit Area ; I No Greater than 4" Wide Pattern <br /> 3 <br /> Concrete To Be Removed for Spa Installation i ; n I (209)599-3317 <br /> z Flush with Plaster, Slip-Resistant 600 N. <br /> Frontagee Rd <br /> Install new waterline depth markers at 4 Y2' depth Ripon, CA <br /> _____ ___ white with 4" black lettering © 2010 Burkett's Pool Plastering, Inc. <br /> APARTMENT BUILDING m APARTMENT BUILDING I Shall Contain the FT Symbol <br /> ILIC#608182 <br /> APARTMENT BUILDING ft.3 m. I Spaced no further than 25'Apart <br /> GAS AND ELECTRICAL RUN FOR SPA i Install new deck depth markers at 4 V2 depth <br /> Flush with Concrete, Slip-Resistant <br /> GAS—1.5"PE PIPE,BURIED IN TRENCH-18" ii EXISTING POOL I white with 4" black letterin <br /> ELECTRICAL—IN CONDUIT,BURIED IN TRENCH-18" BEING REMODELED I g <br /> I Shall Contain the FT Symbol <br /> Spaced no further than 25'Apart <br /> IF <br /> Install NO DIVE Markers <br /> Install on Depths of 6' or less <br /> MAIN ACCESS GATE �, Flush with Concrete, Slip-Resistant Tiles <br /> SECONDARY ACCESS GATE Installed adjacent to depth markers on deck <br /> MEANS of EGREsss i Replace Hand Rail at Shallow End Stairs <br /> Install Commercial 3-Bend Rail <br /> LAUNDRY ROOM �G� i Min. 28" in Height from Deck and stairs <br /> And I Non-Corrosive Material, Bonded <br /> UTILITY I Main Drain —currently split greater than 36"Apart <br /> FENCE LINE i Install Aquastar 10" Round Sumpless Covers (x2) <br /> O ISkimmers—2 Total PAGE <br /> o Single Equalizer Lines on Each <br /> APARTMENT BUILDING i Install Aquastar 10" Round Sumpless Covers on each <br /> Prep and plaster pool with smooth white plaster <br /> I r` <br /> m POOL SPECIFICATIONS MAIN <br /> Surface Area—824 Sq Ft <br /> I <br /> Perimeter— 116 Ft <br /> Volume—24,600 gallons <br /> Turnover rate @ 6 hrs = 68 gpm JOB ADDRESS <br /> APARTMENT BUILDING APARTMENT BUILDING <br /> I <br /> EXISTING EQUIPMENT LIST <br /> POOL Vista Verde <br /> FILTER— Hayward Pro Series S-244T 511 Eastwood Ave <br /> PUMP— Emerson 1 hp (potential 75 gpm @ 60 TDH) Manteca, CA 95336 <br /> SANITIZER— Hayward Chemical Feeder <br /> I FLOW METER— Blue White <br /> FLOW METER READING—65-70 gpm <br /> SUCTION PIPE SIZE (Main Drain) —2.5" PVC <br /> I SUCTION PIPE SIZE (Skimmer) —2.5" PVC <br /> RETURN PIPE SIZE—2.5" PVC <br /> I <br /> I <br /> I <br /> I <br /> NEW SPA SPECIFICATIONS <br /> I <br /> Perimeter: 32 Ft Area: 64 Sq Ft <br /> Size: 8' x 8' Depth: 3'/' <br /> Gallons: approx. 1300 gal <br /> 30 Minute Turnover Rate: 43 gpm <br /> I Number of Jets: 8 Type: Lasco (typ.) Venturi Air Line <br /> Interior Finish <br /> Type: Plaster <br /> Color: White <br /> Plumbing/Circulation Notes <br /> --------------- --------------------------------------------------------------------- I Main Drain (Floor Suction Outlet) <br /> ------------------------------------------------------------------------------- Split a Minimum of 36"Apart <br /> PROPERTYLINE Suction Pipe Size: 2" PVC (5.85 fps @ 60 gpm max. flow through filtration system) <br /> ANSI/ASME/APSP-7 Approved Covers Installed on Each Outlet(x2) <br /> Aquastar 10" Round Sumpless Covers (x2): 170 gpm max. flow rating <br /> VICINITY-MAP Skimmers <br /> No Sump Required <br /> #of Skimmers: 1 <br /> Skimmer Flow Rating: 75 gpm max. <br /> Skimmer Suction Pipe Size: 2" PVC (5.85 fps @ 60 gpm max. flow through filtration system) <br /> Filtration Return <br /> ` Return Line: 2" PVC (5.85 fps @ 60 gpm max. flow through filtration system) <br /> # of Inlets: 2—located in wall of foot well <br /> Each Return Inlet Pipe Size: 2" PVC, with directional eyeball fitting <br /> Jet System—Jandy 2hp PHPF— rated at 158 gpm @ 40 TDH <br /> Suctions Split a Minimum of 36"Apart— Inside Edge of Cover to Inside Edge of Cover <br /> Suction Lines: 4" PVC (4.48 fps @ 175 gpm max. flow through jet system) <br /> NOTE: less than 6 fps on suction side <br /> - 'I+ ANSI/ASME/APSP-7 Approved Covers Installed on Each Outlet(x2) <br /> i Aquastar 10" Round Sumpless Covers (x2): 360 gpm max. flow rating <br /> Requires 3" Deep Sump— per manufacturer's specifications <br /> may, Jet Return Line Loop: 3" PVC (7.73 fps @ 175 gpm max. flow through jet system) <br /> � .' NOTE: less than 8 fps on return side <br /> Return Inlets: 8 Jet Return Inlets, LASCO type Jet Bodies <br /> -� Automatic Fill Device with Anti-Syphon/Backflow Prevention <br /> Lighting <br /> #of Lights in Spa: 1 <br /> Type: Pentair Commercial White LED <br /> CONSTRUCTION PERFORMED UNDER THE FOLLOWING STANDARDS PLAN PAGES/CONTENTS (One 70 watt LED Light is equivalent to one standard 500 watt Light) <br /> SPA Equipment <br /> _ Panel/Controller: Pentair LX-80 Controller with Breaker Panel <br /> PAGE 1: Site Plan, General Overview of Project date 8-22-2014 <br /> California Fire Code 2013 Edition ')AGE 2: Pool Remodel Work With Emergency Shut-off and Timer <br /> California Building Code 2013 Edition Spa Light: (1) Pentair Commercial White LED Lights—Small Niche <br /> PAGE 3: Spa Plumbing and Equipment Layout GFCI Protection for Light located at equipment room <br /> California Mechanical Code 2013 Edition °AGE 4: Spa Tile and Coping Filters: (1) Hayward High Rate Commercial Sand Filter scale 1'" — 10' <br /> California Plumbing Code 2013 Edition PAGE 5: Additional Work, Accessory Safety and Accessibility Equipment r = Max. Commercial Flow Rating: 106 gpm ea& C <br /> California Electrical Code 2013 Edition ( Filter Pump: (1) Jandy PlusHP — PHPF%hp 4 <br /> Energy Efficiency Standards 2008 Edition (Title 24) Potential Flow Rating: 52 gpm @ 60 TDH <br /> Jet Pump: (1) Jandy PlusHP — PHPF 2 hp Drawn By KPM <br /> Potential Flow Rating: 158 gpm @ 40 TDH <br /> Heater: (1) Raypak 400,000 btu <br /> Effluent Flow Meter: Blue White Job <br /> Influent Pressure Guage: (1) Typ. —One Installed on Filter Pump Vista Verde <br /> Effluent Pressure Guage: (1) Typ. —One installed after Filter Name <br /> Sanitizer: Rola Chem chemical feeder pump <br /> Sheet# 1 <br /> Of 5 Sheets <br />
The URL can be used to link to this page
Your browser does not support the video tag.