My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
2050
>
2200 - Hazardous Waste Program
>
PR0514483
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/4/2022 3:43:41 PM
Creation date
10/21/2021 9:47:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0514483
PE
2228
FACILITY_ID
FA0010987
FACILITY_NAME
TEC Equipment
STREET_NUMBER
2050
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
Ave
City
Lathrop
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
2050 E Louise Ave
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of hazardous waste violations that have not been <br /> addressed for TEC Equipment as of October 19 , 2021 . <br /> Open violations from May 01 , 2020 inspection <br /> Violation #502 - Failed to comply with new hazardous waste tank system assessment requirements . <br /> OBSERVATION : This facility has hazardous waste tanks but no tank assessment documents for the following : <br /> -One 240-gallon used oil tank . <br /> -One 220-gallon waste antifreeze tank. <br /> Note: both tanks located near hazardous waste storage area . <br /> REGULATION GUIDANCE : <br /> Title 22 California Code of Regulations section 66265 . 192(a) <br /> Owners or operators of new tank systems or components shall ensure that the foundation , structural support, <br /> seams , connections , and pressure controls ( if applicable) are adequately designed and that the tank system has <br /> sufficient structural strength , compatibility with the waste(s) to be transferred , stored or treated , and corrosion <br /> protection so that it will not collapse , rupture , or fail . The owner or operator shall obtain a written assessment <br /> reviewed and certified by an independent, qualified , professional engineer, registered in California in accordance <br /> with section 66270, 11 (d ) attesting that the system has sufficient structural integrity, is acceptable for the <br /> transferring , storing and treating of hazardous waste , and that the tanks and containment system are suitably <br /> designed to achieve the requirements of this article . This assessment shall be obtained prior to placing the tank <br /> system in service , and shall be kept on file at the facility. This assessment shall also include , at a minimum , the <br /> following information : <br /> ( 1 ) design standard (s) according to which the tank(s) and ancillary equipment are or will be constructed ; <br /> (2) hazardous characteristics of the waste (s) to be handled ; <br /> (3) for new tank systems or components in which the external shell of a metal tank or any external metal component <br /> of the tank system is or will be in contact with the soil or with water, a determination by a corrosion expert of: <br /> (A) factors affecting the potential for corrosion , including but not limited to: <br /> 1 . soil moisture content; <br /> 2 . soil pH ; <br /> 3 . soil sulfides level ; <br /> 4 , soil resistivity ; <br /> 5 , structure to soil potential ; <br /> 6 . influence of nearby underground metal structures (e . g . , piping) ; <br /> 7 . stray electric current; and , <br /> 8 . existing corrosion-protection measures (e . g . , coating , cathodic protection ) , and <br /> ( B) the type and degree of external corrosion protection that are needed to ensure the integrity of the tank system <br /> during the use of the tank system or component, consisting of one or more of the following : <br /> 1 . corrosion-resistant materials of construction such as special alloys or fiberglass-reinforced plastic; <br /> 2 . corrosion-resistant coating (such as epoxy or fiberglass) with cathodic protection (e . g . , impressed current or <br /> sacrificial anodes) ; and <br /> 3 , electrical isolation devices such as insulating joints and flanges ; <br /> (4) for underground tank system components that are likely to be affected by vehicular traffic, a determination of <br /> design or operational measures that will protect the tank system against potential damage ; and <br /> (5) design considerations to ensure that: <br /> (A) tank foundations will maintain the load of a full tank; <br /> ( B ) tank systems will be anchored to prevent flotation or dislodgement where the tank system is placed in a <br /> saturated zone , or is located within a seismic fault zone; and <br /> ( C) tank systems will withstand the effects of frost heave . <br /> Title 22 California Code of Regulations section 66270 . 11 <br /> (d ) Certification . I certify under penalty of law that this document and all attachments were prepared under my <br /> direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and <br /> evaluate the information submitted . Based on my inquiry of the person or persons who manage the system , or those <br /> persons directly responsible for gathering the information , the information submitted is , to be the best of my <br /> knowledge and belief, true, accurate , and complete . I am aware that there are significant penalties for submitting <br /> I false information , including the possibility of fine and imprisonment for knowing violations . <br /> Page 2 of 4 <br />