My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0084281_SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KOSTER
>
33503
>
2600 - Land Use Program
>
SR0084281_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2022 9:36:56 AM
Creation date
10/27/2021 10:53:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0084281
PE
2602
FACILITY_NAME
33503 S KOSTER RD
STREET_NUMBER
33503
Direction
S
STREET_NAME
KOSTER
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
25509032
ENTERED_DATE
9/28/2021 12:00:00 AM
SITE_LOCATION
33503 S KOSTER RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
126
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
33503 S Koster Road Project No.2021-00073 Page 112 <br /> 8.3 Percolation Test Form and Results <br /> The completed percolation test permit and test form are included in the Appendix E of this <br /> report. A shallow percolation test is defined by the EHD as being between 36 and 42 inches <br /> in depth; a satisfactory percolation rate for a shallow test is less than or equal to 60 minutes <br /> per inch drop. The percolation test must demonstrate a satisfactory percolation rate within <br /> the proposed septic system disposal field of each parcel to utilize a standard septic system. <br /> Details of the percolation test is summarized in the Table 7: <br /> Table 7. <br /> Summary of Percolation Test- September 7, 2021 <br /> Percolation percolation <br /> Test No., Test Test Comments <br /> Date Tested Depth Rate Duration (See notes) <br /> (inches) (minutes/inch) <br /> 33503 S Koster Road <br /> P-1 (shallow) 42 9.26 4-hour Satisfactory <br /> Note: A satisfactory percolation rate for a"shallow"test is less than or equal to 60 minutes per inch and greater than or equal to 1 <br /> minute per inch. <br /> The soil within the percolation test area for 33503 S Koster Road demonstrated a satisfactory <br /> percolation rate in accordance with the requirements of the EHD for the use of a standard <br /> septic system. <br /> 9.0 SOIL SUITABILITY STUDY CONCLUSIONS <br /> In summary,a percolation rate that meets the minimum EHD standards was achieved within <br /> the proposed septic disposal area for the parcel located at 33503 S Koster Road; the soil <br /> appears suitable for the use of a standard septic system. <br /> 10.0 LIMITATIONS <br /> The conclusions of this report are established from the information provided regarding the <br /> proposed and existing development and the site conditions as they existed at the time which <br /> we excavated our test hole and performed the percolation test. It was assumed that the test <br /> hole and percolation test result is representative of the subsurface conditions in the general <br /> area. <br /> If there is a substantial amount of time between the submission of this study and <br /> commencement of work at the site, or if conditions have changed due to construction <br /> activities or natural causes at or adjacent to the site, we recommend that our report be <br /> reviewed to access the applicability of the recommendations and conclusions with <br /> consideration regarding changed conditions and or lapse of time. This report should not <br /> be used after 3 years without a review and update from our office. <br /> Petralogix Engineering,InC. <br /> 26675 BruelIa Road,Galt,Ca 95632 <br /> (209)-40o-5729 <br /> www.petralogix.com <br />