120 (STATE ROUTE 120)
>
17000
>
2600 - Land Use Program
>
SR0084280_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 3:59:57 PM
Creation date
10/27/2021 11:35:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0084280
PE
2602
FACILITY_NAME
THE WINE GROUP
STREET_NUMBER
17000
Direction
E
STREET_NAME
STATE ROUTE 120
City
RIPON
Zip
95366
APN
24506029
ENTERED_DATE
9/28/2021 12:00:00 AM
SITE_LOCATION
17000 E HWY 120
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
158
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
W. O.W.T.S. OPERATIONAL DESIGN PARAMETERS AND COMPONENTS <br /> A. PROPOSED O.W.T.S. OPERATION <br /> SSS§3.7. Currently, all onsite domestic wastewater influent sources flow into individual septic <br /> tanks and then disposed of through adjacent leachfields. It is now proposed to centralize all but three <br /> of these septic tank effluent sources and pump it to the future disposal area. Buildings G, G2 and S <br /> will be standalone systems with existing septic tanks and adjacent leachfields which are to remain. <br /> The centralized septic tank effluent will be pumped partially-full (non-pressurized)through a 4" <br /> pipeline designed by others,as illustrated on the attached Plans. The disposal area design criteria, <br /> based upon the findings of these Studies, begin with this pipelined effluent flowing south into a <br /> 4,000 gallon, two compartment Jensen Precast, Inc. septic tank. Although the existing septic tanks <br /> are primary treatment, this 4,000 gallon tank will provide additional treatment to lower nitrogen, <br /> BOD and TSS concentrations by retaining particulate matter and promoting anaerobic digestion. <br /> Sizing for the 4,000 calculated tank capacity(CTC) is based on SJC EHD Form 42-01-004: <br /> 1,125 gal tank+(4,440 gpd ADF x 0.75) = 4,455 gals. Use 4,000 gal septic tank capacity. <br /> In addition to the treatment that will occur in this tank, a Polylok® PL-625 Effluent Filter is to be <br /> installed at the outlet. This filter provides 1/32" filtration, flow volumes up to 8,000 gpd and <br /> prevents particulate matter from entering the pump chamber tank. The filter should be inspected and <br /> cleaned once per year. <br /> The pump chamber septic tank is to be mono construction,two compartment, 1,500 gallon P&L <br /> Concrete, Inc. tank that is traffic rated(H-20 Loading). Both septic tanks are to be traffic rated since <br /> farm machinery will be operating in this location. <br /> The second compartment will contain the Orenco Universal Biotube Pump Vault. A duplex pump <br /> system is to be installed in the Biotube Vault, P/N Orenco PF3005 High Head Effluent Pump, 30 <br /> GPM, '/2 HP, 200V (2 pumps). The housing of both pumps will have additional screening of 1/16". <br /> All spec sheets for the OWTS components are found in Appendix G. The effluent will be pumped to <br /> the future filter bed, as described below. <br /> B. FILTER BED SIZING CALCULATIONS <br /> After the effluent is pressurized in the pump chamber tank, it travels west to the filter bed. The <br /> filter bed must be constructed under the setback requirements promulgated in Section 1.5 of the <br /> OWTS Standards. The vertical ht of the basin is 25 ft; therefore,the west edge of the filter bed <br /> must be: 25 ft x 4 = 100 ft from the top east edge of the stormwater basin. <br /> i <br /> Page -9- <br /> Chesney Consulting <br />
The URL can be used to link to this page
Your browser does not support the video tag.