Laserfiche WebLink
Program Element: 3601 - NEW POOL/SPA PLAN CHECK <br />Telephone: Requestor: MIKE NANTZE, EAGLE POOLS, INC. <br />Inspection Type: 523 - Plan Check/Report Review <br />Address: 2400 CONSTELLATION DR , LATHROP 95330 <br />Date: 05/24/2021Name of Facility: HIDEAWAY <br />Swimming Pool Service Request Inspection Report <br />10:55 am <br />10:05 am <br />Time Out: <br />Time In: <br />Request #: SR0082585 <br />Environmental Health Department <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #3 Safety Signs <br />OBSERVATIONS: Fill in the safety signs prior to opening the pool. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />NOTES <br />Make sure the following are corrected. <br />Gate opening hardware are at 38 inches. Gates and doors shall be equipped with self-closing and self-latching devices to keep <br />them securely closed. Gates and doors shall open outwardly away from the pool except where otherwise prohibited by law. <br />Hand activated door or gate opening hardware shall be located at a height no lower than 42 inches but no higher than 44 <br />inches above the deck or walkway. The pool enclosure shall have a least one means of egress without a key for emergency <br />purposes. Gates shall meet 3119B.2 of California Building Code, Title 24. <br />Hose bibs must be available within 75 feet of all deck areas, and must be protected against backflow. <br />...Part of the fence is not on permanent material. Fencing shall be a minimum of 5 feet high. Openings, holes or gaps in the <br />enclosure, doors and/or gates shall not allow the passage of a 4-inch diameter sphere. The enclosure shall be constructed <br />over a hard and permanent material equivalent to concrete: and shall be designed and constructed so that it cannot be readily <br />climbed by small children. Horizontal and diagonal member designs which might serve as a ladder for small children are <br />prohibited. Horizontal members’ shall be spaced at least 48 inches apart. No planter or other structures that can be 2 of 3 <br />Environmental Health Department climbed shall be permitted within 5 feet of the outside of the pool enclosure or within a 5 foot <br />arc. <br />...The coping in some areas is 3/4 inches below the deck. 3114B.3 Deck slope. The pool's deck surface shall have a slope of <br />no less than 1 percent (1/8 inch per foot) but no more than 2 percent (¼ inch per foot) away from the pool to a deck drainage <br />system and shall be constructed and finished to prevent standing water. <br />...Pool <br />ph 7.8 <br />fc 3 ppm <br />inf18 psi <br />eff 10 psi <br />spa <br />Page 1 of 2EHD 36-01 Rev. 06/30/15 Swimming Pool Service Request Inspection Report <br /> SR0082585 SC523 05/24/2021